SELET CBM13 Скачать руководство пользователя страница 8

STRUMENTAZIONE A MICROCONTROLLORE - 

MICROCONTROLLER INSTRUMENTS 

 8 

 

CICLO MANUALE, L'USCITA SI ATTIVA PER 

VALORI MAGGIORI ED UGUALI E SI 
DISATTIVA PER VALORI MINORI (VALIDO 
ANCHE PER SET2)  

c = 0  

 MANUAL CYCLE, OUTPUT IS ON WHEN 
COUNT EQUAL TO OR GREATER THAN SET 
(RIGHT ALSO FOR SET2) 

L'USCITA SI ATTIVA E RIMANE IN 
COINCIDENZA O PER UN TEMPO 

t

 PER 

VALORI NON IN EGUAGLIANZA ( VALIDO 
ANCHE PER SET2 )  

c = 1  

OUTPUT IS ON WHEN COUNT EQUAL TO SET 
AND STAY ON FOR A TIME 

WHEN COUNT IS 

DIFFERENT TO SET 

CICLO AUTOMATICO CON L'USCITA ATTIVA 
IN COINCIDENZA, RITENUTA PER UN 
TEMPO 

t

, ED AZZERAMENTO DEL 

CONTATORE. IN DOPPIO SET IL RESET E' 
DIPENDENTE DAL SET2 (SET2 E' 
PRIORITARIO RISPETTO A SET1 ) MENTRE 
SET1 SI ATTIVA E RIMANE IN COINCIDENZA 
O SI ATTIVA PER UN TEMPO 

t

 PER VALORI 

NON IN EGUAGLIANZA  

c = 2  

AUTOMATIC CYCLE, WITH OUTPUT ON WHEN 
COUNT EQUAL TO SET FOR A TIME 

AND 

RESET OF COUNT. WITH TWO SETS, RESET 
DEPENDS TO SET2 (SET2 HAS THE RIGHT OF 
WAY TO SET1 ) WHILE  SET1 SWITCH ON IF 
EQUAL TO COUNT AND STAY ON FOR A TIME 

IF SET DIFFERENT TO COUNT 

CICLO AUTOMATICO CON L'USCITA ATTIVA 
IN COINCIDENZA, RITENUTA PER UN 
TEMPO 

t

 , IL CONTATORE SI AZZERA  E IL 

DISPLAY SEGNALA PER TUTTO IL TEMPO 

t

 

IL VALORE DI SET. IN DOPPIO SET IL RESET 
E' DIPENDENTE DA SET2 ( SET2 E' 
PRIORITARIO RISPETTO AL SET1) MENTRE 
SET1 SI ATTIVA E RIMANE IN COINCIDENZA 
O PER UN TEMPO 

t

 PER VALORI NON IN 

EGUAGLIANZA. IN ENTRAMBI I MODI, PER 
TUTTO IL TEMPO DI RITENUTA DEL RELE' IL 
VISUALIZZATORE SEGNALA IL VALORE DEL 
SET O SET2  

c = 3  

 AUTOMATIC CYCLE WITH OUTPUT ON WHEN 
COUNT EQUAL TO SET FOR A TIME 

t , 

RESET 

THE COUNT AND DISPLAY INDICATES  SET 
VALUE FOR ALL THE TIME 

. IN DOUBLE SET 

RESET DEPENDS FROM SET2 (SET2 HAS THE 
RIGHT OF WAY TO SET1) WHILE SET1 
SWITCH ON AND STAY ON IF EQUAL TO 
COUNT OR STAY ON FOR A TIME 

IF 

DIFFERENT TO COUNT. IN BOTH WAYS  
DURING THE ON TIME OF OUTPUTS THE 
DISPLAY INDICATES SET OR SET2 VALUE.   

CICLO AUTOMATICO CON RESET 
DIPENDENTE DAL SET2, AZZERAMENTO 
IMMEDIATO DEL CONTATORE, L'USCITA 
PERMANE ATTIVA PER LA DURATA DEL 
TEMPO 

. L'USCITA RELATIVA AL SET1 E' 

ATTIVA PER VALORI UGUALI O MAGGIORI  
E SI DISATTIVA SU VALORI MINORI. IN 
SINGOLO SET ASSUME LO STESSO 
FUNZIONAMENTO DEL PARAMETRO 2   

c = 4

 

AUTOMATIC CYCLE WITH RESET DEPENDENT 
FROM SET2, IMMEDIATE RESET OF 
COUNTER, OUTPUT ON FOR A TIME 

. THE 

SET1 OUTPUT IS ON WHEN EQUAL TO OR 
GREATER THAN COUNT, AND IT IS OFF WHEN 
LESSER THAN COUNT. IN SINGLE SET 
WORKS IN THE SAME WAY AS PARAMETER 2. 

 

F : 

SELEZIONA LA FUNZIONE DEL SET. RIGUARDA IL POSIZIONAMENTO A RIPOSO DEI RELE', OLTRE 

CHE AD ABILITARE LO STRUMENTO SIA A SINGOLA PRESELEZIONE, CHE A DOPPIA PREDISPOSIZIONE. 
SI INTENDE LA CONDIZIONE DI RIPOSO  QUANDO LO STRUMENTO E' IN CONDIZIONI DI RESET O SI 
TROVA A VALORI MINORI DEL SET, MENTRE SI HA LO STATO DI ATTIVAZIONE PER VALORI UGUALI O 
MAGGIORI DEL SET.  
I

MPORTANTE:

 SE LO STRUMENTO NON E' ALIMENTANTO, LE 

DUE USCITE SONO APERTE (N. A.). 

 

F : 

SELECT THE OUTPUTS FUNCTION. IT CONCERNS THE STAND-BY POSITION OF RELAY OUTPUTS AND 

THE WORKING MODE SELECTION ( ONE OR TWO OUTPUTS). THE STAND-BY CONDITION MEANS THE 
TIMER RESETTED  OR WITH COUNT VALUE LESSER THAN SET, WHILE THE STAND-ON CONDITION 
MEANS TIMER WITH COUNT VALUE GREATER THAN SET . 

WARNING:

 IF THE TIIMER IS UNSUPPLIED, THE 

TWO OUTPUTS ARE OPEN       ( N. O.). 

 

SINGOLO SET, OUT1 NC, OUT2 NO  

F = 0 

 

SINGLE SET, OUT1 NC, OUT2 NO 

DOPPIO SET, OUT1 NO, OUT 2 NO  

F = 1  

DOUBLE SET, OUT1 NO, OUT2 NO 

DOPPIO SET, OUT1 NC, OUT 2 NO  

F = 2  

DOUBLE SET, OUT1 NC, OUT2 NO   

DOPPIO SET, OUT1 NC, OUT 2 NC  

F =3  

DOUBLE SET, OUT1 NC , OUT2 NC 

DOPPIO SET, OUT1 NO, OUT 2 NC 

F =4 

DOUBLE SET, OUT1 NO , OUT2 NC 

 

OFFS : 

IMPOSTAZIONE DELLO ZERO RELATIVO, CAMPO 

+/-9

99999  (99999)

 

OFFS : 

RELATIVE ZERO SET, RANGE +/-  999999 (99999) 

 

b : 

PROGRAMMA IL RESET ALL'ALIMENTAZIONE O IL MANTENIMENTO DEI DATI IN SPEGNIMENTO 

b : 

SELECT THE POWER-ON RESET OR DATA STORAGE IN SWITCH-OFF TIME 

 

Содержание CBM13

Страница 1: ...MANUALE DI RIFERIMENTO CBM13 CBM53 CBM60 CBM63 REFERENCE MANUAL 2000 REV 3 1 Selet Sensor srl I 10151 Torino Via Pozzo 16 Tel 0039 011 4537811 Fax 0039 011 4537868 e mail info selet it ...

Страница 2: ... con il dispositivo non alimentato make electrical connections with no power on the instrument Prestare attenzione alla correttezza del collegamento elettrico Attention on the electrical connections Non collegare i morsetti liberi o privi di indicazione not connect free or no signed plug in QUALUNQUE ERRORE ANNULLA LA GARANZIA EVERY MISTAKE NULLIFY WARRANTY Utilizzare preferibilmente cavo schermat...

Страница 3: ...ODIFICHE CHE RITENGA OPPORTUNE SENZA PREAVVISO MANUFACTURER RESERVE ITSELF THE RIGHT TO MAKE ALL THE SUITABLE CHANGE WITHOUT NOTICE 4 IL PERIODO DI GARANZIA E DI UN ANNO DALLA DATA DI VENDITA WARRANTY TIME IS ONE YEAR AFTER SOLD 5 VIENE RICONOSCIUTA LA GARANZIA SOLO NEL CASO CHE L ARTICOLO NON SIA STATO A APERTO MODIFICATO MANOMESSO B COLLEGATO CORRETTAMENTE IN QUESTO CASO E OBBLIGATORIO FORNIRE S...

Страница 4: ...IONE DEL SET1 USCITA NA1 CHIUSA MEANS SET1 ON OUTPUT NA1 CLOSED SEGMENT O SPENTO INDICA CHE LA VISUALIZZAZIONE E NEL CAMPO POSITIVO MEANS THE INDICATION IS IN POSITIVE RANGE SEGMENT O ACCESO INDICA CHE LA VISUALIZZAZIONE E NEL CAMPO NEGATIVO MEANS THE INDICATION IS IN NEGATIVE RANGE L2 SET 2 INDICA L ATTIVAZIONE DEL SET2 USCITA NA2 CHIUSA MEANS SET2 ON OUTPUT NA2 CLOSED CARATTERISTICHE GENERALI GE...

Страница 5: ...GND GND INGRESSO DI CONTEGGIO 1 COUNT INPUT 1 IN1 IN1 IN1 INGRESSO DI CONTEGGIO 2 COUNT INPUT 2 IN2 IN2 IN2 SELEZIONE NPN PNP NPN PNP SELECT N P N P INGRESSO BLOCCO CONTEGGIO GATE INPUT EN EN EN INGRESSO AUSILIARIO AUX INPUT IN3 IN3 INGRESSO DI RESET O CARICO OFFSET RESET INPUT OR OFFSET LOADING RST RST RST USCITA SINGOLO SET SINGLE SET OUPUT NA1 NC C NA2 NA1 C1 NC1 NA2 C2 NC2 NA1 NC C NA2 USCITA ...

Страница 6: ...NUMERO DI IMPULSI GIRO O LINEARI DEL TRASDUTTORE FATTORE DI DIVISIONE CAMPO 1 A 999999 99999 n NUMBER OF PULSES FOR REVOLUTION OR LINEAR PULSE OF TRANSDUCER DIVISION FACTOR RANGE 1 TO 999999 99999 S SVILUPPO O RISOLUZIONE DETERMINATI DAGLI IMPULSI DEL TRASDUTTORE FATTORE DI MOLTIPLICAZIONE CAMPO 1 A 999999 99999 S DEVELOPMENT OR RISOLUTION GIIVEN BY NR OF PULSES OF TRANSDUCER MULTIPLY FACTOR RANGE...

Страница 7: ...T SIGNIFICA CHE AZZERANDO IL CONTEGGIO IL CONTATORE VA AL VALORE DI OFFSET O ZERO RELATIVO LEGEND THIS TABLE SHOWS RESET MODALITY PANEL RESET INPUT RST IS ALWAYS ENABLED WHILE FRONT RESET SHOULD BE ENABLED OR NOT DISPLAY 0 MEANS WHEN A RESET SIGNAL OCCURS COUNTER IS RESET TO ZERO DISPLAY OFFSET MEANS WHEN A RESET SIGNAL OCCURS COUNTER IS RESET TO OFFSET OR RELATIVE ZERO A SELEZIONA L INTERVENTO DE...

Страница 8: ...NT TO COUNT IN BOTH WAYS DURING THE ON TIME OF OUTPUTS THE DISPLAY INDICATES SET OR SET2 VALUE CICLO AUTOMATICO CON RESET DIPENDENTE DAL SET2 AZZERAMENTO IMMEDIATO DEL CONTATORE L USCITA PERMANE ATTIVA PER LA DURATA DEL TEMPO t L USCITA RELATIVA AL SET1 E ATTIVA PER VALORI UGUALI O MAGGIORI E SI DISATTIVA SU VALORI MINORI IN SINGOLO SET ASSUME LO STESSO FUNZIONAMENTO DEL PARAMETRO 2 c 4 AUTOMATIC ...

Страница 9: ...RIPRISTINARLI u BY u PARAMETER AN INCREMENTAL 0 OR A DECREMENTAL 1 COUNT SHOULD BE CHOICE INCREMENTAL COUNT MEANS RESET TO ZERO OR RESET TO OFFSET AND COUNTING UP TO SET IF THIS IS POSITIVE DECREMENTAL COUNT MEANS RESET TO SET2 WITHOUT OUTPUT ACTIVATION AND COUNTING UP TO ZERO OR UP TO OFFSET WITH OUTPUT ACTIVATION IMPORTANT THE u PARAMETER CHANGE MEANS A RESET OF SETS AND OFFSET VALUES SO THEY HA...

Страница 10: ...D SHIFT LEFT THE JUMPER EXECUTE THIS OPERATION WITHOUT SUPPLY TO THE COUNTER PNP NPN AVVERTENZA NON CORTOCIRCUITARE TUTTI I TRE PIN INSIEME PER LA SERIE 72X72 E 48X96 CONNETTERE IL MORSETTO N P A 12 PER INGRESSI NPN OPPURE N P CON GND PER INGRESSI PNP WARNING DO NOT SHORT CIRCUIT ALL THREE PINS TOGETHER CONNECTED N P WITH 12 FOR NPN INPUT OR N P WITH GND FOR PNP INPUT ON 72x72 AND 48x96 TYPE VISTA...

Страница 11: ...IONALI IL PARAMETRO INP SIA PROGRAMMATO ADEGUATAMENTE 1 0 NON RESETTA NON BLOCCA IL CONTEGGIO 1 1 VERIFICARE CHE LA LOGICA USATA SIA COMPATIBILE CON IL SEGNALE DI INGRESSO E O CHE IL MORSETTO N P SIA COLLEGATO 1 2 VERIFICARE CHE IL SEGNALE ARRIVI IN MORSETTIERA 2 0 NON VISUALIZZA CORRETTAMENTE 2 1 VERIFICARE I RAPPORTI DI MOLTIPLICAZIONE E DIVISIONE 2 2 VERIFICARE CHE LA VELOCITA O FREQUENZA DI CO...

Страница 12: ... D IN G R E S S I P E R E N C O D E R IN P U T S F O R E N C O D E R R E L A Y S IN G R E S S I P E R S E N S O R I P N P 1 2 IN 1 IN 2 M IC R O M IC R O G N D IN 1 IN 2 N A M U R N A M U R G N D IN 1 IN 2 M IC R O M IC R O IN G R E S S I P E R S E N S O R I N P N U S C IT A N P N O U T 1 O U T 2 C O M N P N O U T P U T U S C IT A P N P P N P O U T P U T O U T 1 O U T 2 C O M 1 2 N P 7 2 X 7 2 4 8...

Отзывы: