 6 

IN PRG INCREMENTA LA CIFRA 
LAMPEGGIANTE.  

Ù

Ù

/ABS-

REL  

IN PRG IT INCREASES BLINKING DIGIT .

 

l

l

 PROGRAMMAZIONE                                          

PROGRAM 

PREMENDO IL TASTO  

PRG 

 IL CBM SI TROVA NEL MENU’ DI PROGRAMMAZIONE.  SECONDO IL 

MODELLO E ALCUNE FUNZIONI  SCELTE SUL DISPLAY COMPARE LA PROGRAMMAZIONE DEI SET.  

PUSHING 

PRG 

KEY THE CBM IS IN THE PROGRAM MENU. DEPENDING ON THE MODEL OR ON THE 

FUNCTION PROGRAMMED, THE DISPLAY SHOWS THE SET PROGRAM. 
 

SET

.

 IMPOSTAZIONE DELLA  SOGLIA DI INTERVENTO, CAMPO IMPOSTABILE DA 0 A +/- 999999 (99999). 

COMPARE SE IL PARAMETRO 

E' ZERO. 

SET

 OUTPUT PRESET , RANGE 0 TO +/- 999999 (99999) , ABLE IF 

F

 PARAMETER IS ZERO 

 

SET1 : 

IMPOSTAZIONE DELLA PRIMA SOGLIA DI INTERVENTO, CAMPO IMPOSTABILE DA 0 A +/- 999999  

(99999) . COMPARE SE IL PARAMETRO 

F

 NON E' ZERO. 

SET1 : 

FIRST OUTPUT PRESET , RANGE 0 TO +/-999999  (99999). ABLE IF 

F

 PARAMETER IS NOT ZERO 

 

SET2 : 

IMPOSTAZIONE DELLA SECONDA SOGLIA DI INTERVENTO, CAMPO IMPOSTABILE DA 0 A +/- 

999999  (99999). 
COMPARE SE IL PARAMETRO 

F

 NON E' ZERO.

 

SET2 : 

SECOND OUTPUT PRESET , RANGE 0 TO +/- 999999 (99999), ABLE IF 

F

 PARAMETER IS NOT ZERO 

S.L. : 

INDICA IL LIVELLO DI PROGRAMMA, APPARE COME INFORMAZIONE DOPO LA PROGRAMMAZIONE 

DEI SET  OPPURE DOPO LA PROGRAMMAZIONE DELLA PASSWORD. 

S.L. :

PROGRAM LEVEL, IT APPEARS AS INFORMATION AFTER THE SETUP PROCEDURE OR AFTER 

PASSWORD PROGRAMMING

 

 

n : 

NUMERO DI IMPULSI GIRO O LINEARI DEL TRASDUTTORE (FATTORE DI DIVISIONE) CAMPO 1 A 

999999 (99999).

 

n : 

NUMBER OF PULSES FOR REVOLUTION OR LINEAR PULSE OF TRANSDUCER (DIVISION FACTOR), 

RANGE 1 TO 999999 (99999). 
 

S: 

SVILUPPO O RISOLUZIONE DETERMINATI DAGLI IMPULSI DEL TRASDUTTORE (FATTORE DI 

MOLTIPLICAZIONE), CAMPO 1 A 999999 (99999). 

  

S: 

DEVELOPMENT OR RISOLUTION GIIVEN BY NR OF PULSES OF TRANSDUCER (MULTIPLY FACTOR), 

RANGE 1 TO 999999 (99999)

 

 
InP : 

SELEZIONA IL MODO D'INGRESSO, CAMPO 0 - 8.

 

InP : 

INPUT MODE SELECT, RANGE 0 - 8 

 
INGRESSO DA ENCODER O SEGNALI 
SFASATI DI 90 GRADI  

 InP=0 

 

ENCODER OR 90° OUT OF  PHASE 
SIGNAL INPUTS 

IN1

 = CLOCK SUL FRONTE DI SALITA  

InP=1

  

IN1

 = CLOCK ON RISE TIME 

IN2

 = LIVELLO ALTO = UP  

 

IN2

 = HIGH LEVEL = UP 

         LIVELLO BASSO = DOWN  

 

         

 LOW LEVEL = DOWN  

IN1

 = CLOCK SUL FRONTE DI DISCESA  

InP = 2

  

IN1

 = CLOCK ON FALL TIME

 

N2

 = LIVELLO ALTO = DOWN  

 

IN2

 = HIGH LEVEL = DOWN

 

         LIVELLO BASSO = UP     

 

          LOW LEVEL = UP

 

IN2

 = CLOCK SUL FRONTE DI SALITA  

InP=3

  

IN2

 = CLOCK ON RISE TIME 

IN1

 = LIVELLO ALTO = DOWN  

 

IN1

 = HIGH LEVEL = DOWN 

         LIVELLO BASSO =UP  

 

        

 LOW LEVEL = UP  

IN2

 = CLOCK SUL FRONTE DI DISCESA  

InP = 4

  

IN2

 = CLOCK ON FALL TIME

 

IN1

 = LIVELLO ALTO =UP  

 

IN1

 = HIGH LEVEL = UP

 

         LIVELLO BASSO = DOWN     

 

          LOW LEVEL = DOWN

 

IN1

 CLOCK INCREMENTALE SUL FRONTE DI 

SALITA  

Inpt = 5 

 

IN1

 UP COUNTING ON RISE TIME 

IN2

  CLOCK DECREMENTALE SUL FRONTE 

DI SALITA  

 

IN2

 DOWN COUNTING ON RISE TIME  

IN1

 CLOCK INCREMENTALE SUL FRONTE DI 

DISCESA  

InP = 6 

 

IN1

 UP COUNTING ON FALL TIME 

IN2

 CLOCKDECREMENTALE SUL FRONTE DI 

DISCESA  

 

IN2

 DOWN COUNTING ON FALL TIME  

IN1

 CLOCK INCREMENTALE SUL FRONTE DI 

SALITA  

InP = 7 

 

IN1

 UP COUNTING ON RISE TIME 

Содержание CBM13

Страница 1: ...MANUALE DI RIFERIMENTO CBM13 CBM53 CBM60 CBM63 REFERENCE MANUAL 2000 REV 3 1 Selet Sensor srl I 10151 Torino Via Pozzo 16 Tel 0039 011 4537811 Fax 0039 011 4537868 e mail info selet it ...

Страница 2: ... con il dispositivo non alimentato make electrical connections with no power on the instrument Prestare attenzione alla correttezza del collegamento elettrico Attention on the electrical connections Non collegare i morsetti liberi o privi di indicazione not connect free or no signed plug in QUALUNQUE ERRORE ANNULLA LA GARANZIA EVERY MISTAKE NULLIFY WARRANTY Utilizzare preferibilmente cavo schermat...

Страница 3: ...ODIFICHE CHE RITENGA OPPORTUNE SENZA PREAVVISO MANUFACTURER RESERVE ITSELF THE RIGHT TO MAKE ALL THE SUITABLE CHANGE WITHOUT NOTICE 4 IL PERIODO DI GARANZIA E DI UN ANNO DALLA DATA DI VENDITA WARRANTY TIME IS ONE YEAR AFTER SOLD 5 VIENE RICONOSCIUTA LA GARANZIA SOLO NEL CASO CHE L ARTICOLO NON SIA STATO A APERTO MODIFICATO MANOMESSO B COLLEGATO CORRETTAMENTE IN QUESTO CASO E OBBLIGATORIO FORNIRE S...

Страница 4: ...IONE DEL SET1 USCITA NA1 CHIUSA MEANS SET1 ON OUTPUT NA1 CLOSED SEGMENT O SPENTO INDICA CHE LA VISUALIZZAZIONE E NEL CAMPO POSITIVO MEANS THE INDICATION IS IN POSITIVE RANGE SEGMENT O ACCESO INDICA CHE LA VISUALIZZAZIONE E NEL CAMPO NEGATIVO MEANS THE INDICATION IS IN NEGATIVE RANGE L2 SET 2 INDICA L ATTIVAZIONE DEL SET2 USCITA NA2 CHIUSA MEANS SET2 ON OUTPUT NA2 CLOSED CARATTERISTICHE GENERALI GE...

Страница 5: ...GND GND INGRESSO DI CONTEGGIO 1 COUNT INPUT 1 IN1 IN1 IN1 INGRESSO DI CONTEGGIO 2 COUNT INPUT 2 IN2 IN2 IN2 SELEZIONE NPN PNP NPN PNP SELECT N P N P INGRESSO BLOCCO CONTEGGIO GATE INPUT EN EN EN INGRESSO AUSILIARIO AUX INPUT IN3 IN3 INGRESSO DI RESET O CARICO OFFSET RESET INPUT OR OFFSET LOADING RST RST RST USCITA SINGOLO SET SINGLE SET OUPUT NA1 NC C NA2 NA1 C1 NC1 NA2 C2 NC2 NA1 NC C NA2 USCITA ...

Страница 6: ...NUMERO DI IMPULSI GIRO O LINEARI DEL TRASDUTTORE FATTORE DI DIVISIONE CAMPO 1 A 999999 99999 n NUMBER OF PULSES FOR REVOLUTION OR LINEAR PULSE OF TRANSDUCER DIVISION FACTOR RANGE 1 TO 999999 99999 S SVILUPPO O RISOLUZIONE DETERMINATI DAGLI IMPULSI DEL TRASDUTTORE FATTORE DI MOLTIPLICAZIONE CAMPO 1 A 999999 99999 S DEVELOPMENT OR RISOLUTION GIIVEN BY NR OF PULSES OF TRANSDUCER MULTIPLY FACTOR RANGE...

Страница 7: ...T SIGNIFICA CHE AZZERANDO IL CONTEGGIO IL CONTATORE VA AL VALORE DI OFFSET O ZERO RELATIVO LEGEND THIS TABLE SHOWS RESET MODALITY PANEL RESET INPUT RST IS ALWAYS ENABLED WHILE FRONT RESET SHOULD BE ENABLED OR NOT DISPLAY 0 MEANS WHEN A RESET SIGNAL OCCURS COUNTER IS RESET TO ZERO DISPLAY OFFSET MEANS WHEN A RESET SIGNAL OCCURS COUNTER IS RESET TO OFFSET OR RELATIVE ZERO A SELEZIONA L INTERVENTO DE...

Страница 8: ...NT TO COUNT IN BOTH WAYS DURING THE ON TIME OF OUTPUTS THE DISPLAY INDICATES SET OR SET2 VALUE CICLO AUTOMATICO CON RESET DIPENDENTE DAL SET2 AZZERAMENTO IMMEDIATO DEL CONTATORE L USCITA PERMANE ATTIVA PER LA DURATA DEL TEMPO t L USCITA RELATIVA AL SET1 E ATTIVA PER VALORI UGUALI O MAGGIORI E SI DISATTIVA SU VALORI MINORI IN SINGOLO SET ASSUME LO STESSO FUNZIONAMENTO DEL PARAMETRO 2 c 4 AUTOMATIC ...

Страница 9: ...RIPRISTINARLI u BY u PARAMETER AN INCREMENTAL 0 OR A DECREMENTAL 1 COUNT SHOULD BE CHOICE INCREMENTAL COUNT MEANS RESET TO ZERO OR RESET TO OFFSET AND COUNTING UP TO SET IF THIS IS POSITIVE DECREMENTAL COUNT MEANS RESET TO SET2 WITHOUT OUTPUT ACTIVATION AND COUNTING UP TO ZERO OR UP TO OFFSET WITH OUTPUT ACTIVATION IMPORTANT THE u PARAMETER CHANGE MEANS A RESET OF SETS AND OFFSET VALUES SO THEY HA...

Страница 10: ...D SHIFT LEFT THE JUMPER EXECUTE THIS OPERATION WITHOUT SUPPLY TO THE COUNTER PNP NPN AVVERTENZA NON CORTOCIRCUITARE TUTTI I TRE PIN INSIEME PER LA SERIE 72X72 E 48X96 CONNETTERE IL MORSETTO N P A 12 PER INGRESSI NPN OPPURE N P CON GND PER INGRESSI PNP WARNING DO NOT SHORT CIRCUIT ALL THREE PINS TOGETHER CONNECTED N P WITH 12 FOR NPN INPUT OR N P WITH GND FOR PNP INPUT ON 72x72 AND 48x96 TYPE VISTA...

Страница 11: ...IONALI IL PARAMETRO INP SIA PROGRAMMATO ADEGUATAMENTE 1 0 NON RESETTA NON BLOCCA IL CONTEGGIO 1 1 VERIFICARE CHE LA LOGICA USATA SIA COMPATIBILE CON IL SEGNALE DI INGRESSO E O CHE IL MORSETTO N P SIA COLLEGATO 1 2 VERIFICARE CHE IL SEGNALE ARRIVI IN MORSETTIERA 2 0 NON VISUALIZZA CORRETTAMENTE 2 1 VERIFICARE I RAPPORTI DI MOLTIPLICAZIONE E DIVISIONE 2 2 VERIFICARE CHE LA VELOCITA O FREQUENZA DI CO...

Страница 12: ... D IN G R E S S I P E R E N C O D E R IN P U T S F O R E N C O D E R R E L A Y S IN G R E S S I P E R S E N S O R I P N P 1 2 IN 1 IN 2 M IC R O M IC R O G N D IN 1 IN 2 N A M U R N A M U R G N D IN 1 IN 2 M IC R O M IC R O IN G R E S S I P E R S E N S O R I N P N U S C IT A N P N O U T 1 O U T 2 C O M N P N O U T P U T U S C IT A P N P P N P O U T P U T O U T 1 O U T 2 C O M 1 2 N P 7 2 X 7 2 4 8...

Отзывы: