STRUMENTAZIONE A MICROCONTROLLORE - 

MICROCONTROLLER INSTRUMENTS 

 5 

ANTIGRAFFIO 

FRONT PANEL IN ANTISCRATCH POLYCARBONATE

 

VISUALIZZATORE 5 / 6 CIFRE ROSSE AD ALTA 
EFFICIENZA 

  5 / 6 RED DIGITS INDICATOR HIGH LUMINOSITY

 

 

 

 

TASTIERA DI PROGRAMMAZIONE A 4 TASTI 

 4 KEYS PROGRAMMING KEYBOARD

 

 

 

 

MENU' DI PROGRAMMAZIONE GUIDATO

  

EASY PROGRAMMING

 

 

 

 

MASSIMA FREQUENZA DI INGRESSO 5 KH

   

MAXIMUM COUNT RATE 5 KHz

 

 

 

 

SCALE E RISOLUZIONI PROGRAMMABILI  

PROGRAMMABLE SCALES AND RESOLUTION

 

 

 

 

INGRESSI DI CONTEGGIO ED AUSILIARI  
PROGRAMMABILI NPN / PNP 10-30Vdc   

AUX AND COUNT INPUTS NPN / PNP PROGRAMMABLE  
10/30Vdc

 

 

 

 

ALIMENTAZIONE ESTERNA  

EXTERNAL PWR SUPPLY 

 

11 VCC, 
30mA

 

12VCC, 50mA

 

12VCC, 
50mA

 

••

 MODELLI DISPONIBILI   

AVAILABLE MODELS 

FOMATO 

DIGIT - SET 

24Vdc 

24Vac 

110Vac 

220Vac 

48X48 

5 DIGIT + 2SET 

CBM13/24Vdc 

CBM13/24 

CBM13/110 

CBM13/220 

2 X72 

6 DIGIT + 2SET 

 

CBM53/24Vdc 

 

CBM53/24 

 

CBM53/110 

 

CBM53/220 

48X96 

6 DIGIT 

6 DIGIT + 2SET 

CBM60/24Vdc 
CBM63/24Vdc 

CBM60/24 
CBM63/24 

CBM60/110 
CBM63/110 

CBM60/220 
CBM63/220 

••

 MORSETTIERE     

 TERMINALS 

 

48X48 

72X72 

48X96 

ALIMENTAZIONE                     

SUPPLY VOLTAGE

 

0/24/110/220 

0/24/110/220 

0/24/110/220 

PRESA DI TERRA                    

GROUND REFERENCE

 

PE

 

PE

 

PE

 

RIFERIMENTO NEGATIVO     

NEGATIVE REFERENCE

 

GND

 

GND

 

GND

 

INGRESSO DI CONTEGGIO 1  

COUNT INPUT 1

 

IN1

 

IN1

 

IN1

 

I

NGRESSO DI CONTEGGIO 2  

COUNT INPUT 2

 

IN2

 

IN2

 

IN2

 

SELEZIONE NPN / PNP            

NPN / PNP SELECT

 

 

N/P

 

N/P

 

INGRESSO BLOCCO CONTEGGIO   

GATE INPUT

 

EN

 

EN

 

EN

 

INGRESSO AUSILIARIO            

AUX. INPUT

 

 

IN3

 

IN3

 

INGRESSO DI RESET O CARICO OFFSET   

RESET INPUT OR OFFSET  LOADING

 

RST

 

RST

 

RST

 

USCITA – SINGOLO SET          

SINGLE SET OUPUT 

NA1 (NC) –C – 

NA2 

NA1 – C1 – NC1 
NA2 – C2 – NC2 

NA1 (NC) –C 

– NA2 

USCITA DOPPIO SET               

DOUBLE SET OUTPUT 

NA1 - C -NA2 

NA1 – C1 – NC1 
NA2 – C2 – NC2 

NA1 - C -NA2 

••

TASTIERA                                          

KEYBOARD 

PREMENDO PER LA PRIMA VOLTA SI ENTRA 
IN PROGRAMMAZIONE, LE SUCCESSIVE PER 
MEMORIZZARE IL DATO E CAMBIARE I MENU'  

PRG  

PUSH FIRST TIME TO ENTER IN SETUP 
THE OTHER TO STORE DATA AND TO 
CHANGE MENU

 

PREMENDO SI MEMORIZZA IL DATO E SI 
ESCE DALLA CONDIZIONE DI 
PROGRAMMAZIONE. IN  RUN, SE ABILITATO 
RESETTA O CARICA IL VALORE DI OFFSET 
NEL CONTATORE 

ENTER     
RESET  

PUSH TO ESCAPE FROM SETUP 
CONDITION AND STORE DATA. 
IN RUN, IF ENABLED,IT ALLOWS TO RESET 
OR TO LOAD OFFSET VALUE ON 
COUNTER. 

IN RUN EFFETTUA UNA VISUALIZZAZIONE DI 
ALCUNI PARAMETRI SENZA POTERLI 
MODIFICARE. IN PROGRAMMAZIONE SERVE A 
SPOSTARE DA DESTRA A SINISTRA LA CIFRA 
LAMPEGGIANTE  

×

×

/SCROLL  

IN RUN IT ALLOWS TO DISPLAY SOME 
DATA WITHOUT MODIFY. IN THIS PHASE 
ALL INTERNAL AND EXTERNAL COMMAND 
ARE WORKING (COUNT, COMPARE AND 
OUTPUT DRIVING, RESET AND GATE 
INPUTS). IN SETUP IT ALLOWS TO SHIFT 
LEFT THE BLINKING DIGIT

 

Содержание CBM13

Страница 1: ...MANUALE DI RIFERIMENTO CBM13 CBM53 CBM60 CBM63 REFERENCE MANUAL 2000 REV 3 1 Selet Sensor srl I 10151 Torino Via Pozzo 16 Tel 0039 011 4537811 Fax 0039 011 4537868 e mail info selet it ...

Страница 2: ... con il dispositivo non alimentato make electrical connections with no power on the instrument Prestare attenzione alla correttezza del collegamento elettrico Attention on the electrical connections Non collegare i morsetti liberi o privi di indicazione not connect free or no signed plug in QUALUNQUE ERRORE ANNULLA LA GARANZIA EVERY MISTAKE NULLIFY WARRANTY Utilizzare preferibilmente cavo schermat...

Страница 3: ...ODIFICHE CHE RITENGA OPPORTUNE SENZA PREAVVISO MANUFACTURER RESERVE ITSELF THE RIGHT TO MAKE ALL THE SUITABLE CHANGE WITHOUT NOTICE 4 IL PERIODO DI GARANZIA E DI UN ANNO DALLA DATA DI VENDITA WARRANTY TIME IS ONE YEAR AFTER SOLD 5 VIENE RICONOSCIUTA LA GARANZIA SOLO NEL CASO CHE L ARTICOLO NON SIA STATO A APERTO MODIFICATO MANOMESSO B COLLEGATO CORRETTAMENTE IN QUESTO CASO E OBBLIGATORIO FORNIRE S...

Страница 4: ...IONE DEL SET1 USCITA NA1 CHIUSA MEANS SET1 ON OUTPUT NA1 CLOSED SEGMENT O SPENTO INDICA CHE LA VISUALIZZAZIONE E NEL CAMPO POSITIVO MEANS THE INDICATION IS IN POSITIVE RANGE SEGMENT O ACCESO INDICA CHE LA VISUALIZZAZIONE E NEL CAMPO NEGATIVO MEANS THE INDICATION IS IN NEGATIVE RANGE L2 SET 2 INDICA L ATTIVAZIONE DEL SET2 USCITA NA2 CHIUSA MEANS SET2 ON OUTPUT NA2 CLOSED CARATTERISTICHE GENERALI GE...

Страница 5: ...GND GND INGRESSO DI CONTEGGIO 1 COUNT INPUT 1 IN1 IN1 IN1 INGRESSO DI CONTEGGIO 2 COUNT INPUT 2 IN2 IN2 IN2 SELEZIONE NPN PNP NPN PNP SELECT N P N P INGRESSO BLOCCO CONTEGGIO GATE INPUT EN EN EN INGRESSO AUSILIARIO AUX INPUT IN3 IN3 INGRESSO DI RESET O CARICO OFFSET RESET INPUT OR OFFSET LOADING RST RST RST USCITA SINGOLO SET SINGLE SET OUPUT NA1 NC C NA2 NA1 C1 NC1 NA2 C2 NC2 NA1 NC C NA2 USCITA ...

Страница 6: ...NUMERO DI IMPULSI GIRO O LINEARI DEL TRASDUTTORE FATTORE DI DIVISIONE CAMPO 1 A 999999 99999 n NUMBER OF PULSES FOR REVOLUTION OR LINEAR PULSE OF TRANSDUCER DIVISION FACTOR RANGE 1 TO 999999 99999 S SVILUPPO O RISOLUZIONE DETERMINATI DAGLI IMPULSI DEL TRASDUTTORE FATTORE DI MOLTIPLICAZIONE CAMPO 1 A 999999 99999 S DEVELOPMENT OR RISOLUTION GIIVEN BY NR OF PULSES OF TRANSDUCER MULTIPLY FACTOR RANGE...

Страница 7: ...T SIGNIFICA CHE AZZERANDO IL CONTEGGIO IL CONTATORE VA AL VALORE DI OFFSET O ZERO RELATIVO LEGEND THIS TABLE SHOWS RESET MODALITY PANEL RESET INPUT RST IS ALWAYS ENABLED WHILE FRONT RESET SHOULD BE ENABLED OR NOT DISPLAY 0 MEANS WHEN A RESET SIGNAL OCCURS COUNTER IS RESET TO ZERO DISPLAY OFFSET MEANS WHEN A RESET SIGNAL OCCURS COUNTER IS RESET TO OFFSET OR RELATIVE ZERO A SELEZIONA L INTERVENTO DE...

Страница 8: ...NT TO COUNT IN BOTH WAYS DURING THE ON TIME OF OUTPUTS THE DISPLAY INDICATES SET OR SET2 VALUE CICLO AUTOMATICO CON RESET DIPENDENTE DAL SET2 AZZERAMENTO IMMEDIATO DEL CONTATORE L USCITA PERMANE ATTIVA PER LA DURATA DEL TEMPO t L USCITA RELATIVA AL SET1 E ATTIVA PER VALORI UGUALI O MAGGIORI E SI DISATTIVA SU VALORI MINORI IN SINGOLO SET ASSUME LO STESSO FUNZIONAMENTO DEL PARAMETRO 2 c 4 AUTOMATIC ...

Страница 9: ...RIPRISTINARLI u BY u PARAMETER AN INCREMENTAL 0 OR A DECREMENTAL 1 COUNT SHOULD BE CHOICE INCREMENTAL COUNT MEANS RESET TO ZERO OR RESET TO OFFSET AND COUNTING UP TO SET IF THIS IS POSITIVE DECREMENTAL COUNT MEANS RESET TO SET2 WITHOUT OUTPUT ACTIVATION AND COUNTING UP TO ZERO OR UP TO OFFSET WITH OUTPUT ACTIVATION IMPORTANT THE u PARAMETER CHANGE MEANS A RESET OF SETS AND OFFSET VALUES SO THEY HA...

Страница 10: ...D SHIFT LEFT THE JUMPER EXECUTE THIS OPERATION WITHOUT SUPPLY TO THE COUNTER PNP NPN AVVERTENZA NON CORTOCIRCUITARE TUTTI I TRE PIN INSIEME PER LA SERIE 72X72 E 48X96 CONNETTERE IL MORSETTO N P A 12 PER INGRESSI NPN OPPURE N P CON GND PER INGRESSI PNP WARNING DO NOT SHORT CIRCUIT ALL THREE PINS TOGETHER CONNECTED N P WITH 12 FOR NPN INPUT OR N P WITH GND FOR PNP INPUT ON 72x72 AND 48x96 TYPE VISTA...

Страница 11: ...IONALI IL PARAMETRO INP SIA PROGRAMMATO ADEGUATAMENTE 1 0 NON RESETTA NON BLOCCA IL CONTEGGIO 1 1 VERIFICARE CHE LA LOGICA USATA SIA COMPATIBILE CON IL SEGNALE DI INGRESSO E O CHE IL MORSETTO N P SIA COLLEGATO 1 2 VERIFICARE CHE IL SEGNALE ARRIVI IN MORSETTIERA 2 0 NON VISUALIZZA CORRETTAMENTE 2 1 VERIFICARE I RAPPORTI DI MOLTIPLICAZIONE E DIVISIONE 2 2 VERIFICARE CHE LA VELOCITA O FREQUENZA DI CO...

Страница 12: ... D IN G R E S S I P E R E N C O D E R IN P U T S F O R E N C O D E R R E L A Y S IN G R E S S I P E R S E N S O R I P N P 1 2 IN 1 IN 2 M IC R O M IC R O G N D IN 1 IN 2 N A M U R N A M U R G N D IN 1 IN 2 M IC R O M IC R O IN G R E S S I P E R S E N S O R I N P N U S C IT A N P N O U T 1 O U T 2 C O M N P N O U T P U T U S C IT A P N P P N P O U T P U T O U T 1 O U T 2 C O M 1 2 N P 7 2 X 7 2 4 8...