STRUMENTAZIONE A MICROCONTROLLORE -
MICROCONTROLLER INSTRUMENTS
10
••
SELEZIONE NPN/PNP 48X48
PNP/NPN SELECT
LO STRUMENTO 48x48 VERRA' CONSEGNATO CON CONFIGURAZIONE NPN . PER CAMBIARE
L'INGRESSO OCCORRE TOGLIERE IL PANNELLO POSTERIORE , FAR LEVA SU DI UN JUMPER E
SPOSTARLO A SINISTRA . OPERAZIONE DA ESEGUIRE A STRUMENTO SPENTO.
THE COUNTER 48x48 IS NORMALLY SET ON NPN CONFIGURATION . TO CHANGE THIS REAR PANEL
MUST BE REMOVED AND SHIFT LEFT THE JUMPER.
EXECUTE THIS OPERATION WITHOUT SUPPLY TO THE COUNTER.
P NP
NP N
~
~
~
~
~
~
~
~
AVVERTENZA
NON CORTOCIRCUITARE TUTTI I TRE PIN INSIEME
PER LA SERIE 72X72 E 48X96 CONNETTERE IL MORSETTO N/P A +12 PER INGRESSI NPN OPPURE N/P
CON GND PER INGRESSI PNP.
WARNING
DO NOT SHORT-CIRCUIT ALL THREE PINS TOGETHER
CONNECTED N/P WITH +12 FOR NPN INPUT OR N/P WITH GND FOR PNP INPUT ON 72x72 AND 48x96
TYPE.
••