background image

EN

 F

RONTPANEL

The unit includes the operating organs shown in figure (Fig. 1).
The operation shall be performed in the manner used by mobile phones: communication can be established with the device, navigation performed in menu system, setting 
performed on basis of information displayed on the screen through function keys, direction keys, OK-button and Esc-button.
Esc-button can be used at any point of menu system to prevent unintentional or erroneous data modification.

1 - DISPLAY

 colour display with backlight to show or visualise miscellaneous status information, parameters settled or any other function/information

2 - FUNCTION KEYS

 they have no permanent function, this is the text displayed on screen informing about their actual role (like for mobile phones)

3 - 

DIRECTION KEYS

 they enable navigation within information, menus or parameter settings displayed on the screen  (like for mobile phones)

4 - OK BUTTON

 its main task is confirmation of information, or parameter settings

5 - ESC BUTTON

 its main task is rejecting information, or parameter settings by returning to main screen

 C

ONTROL 

B

OARD

The panel is composed of control, signalling and connecting units shown in figure (Fig. 4A, 4B, 4C, 4D).
Wire connections can easily be performed by using dismantling terminal blocks and terminal block functions marked on panel by pictures if possible.
You shall not leave the box cover hanging on the flat multicore cable in any case! When installing, you shall provide a support to the box cover or have it removed by 
disconnecting the easily dismantling line terminals!

1 - TERMINAL BLOCKS

 see their detailed description and connections in next chapter

2 - 

RELAY LEDS

 signalling the status of corresponding relay

Lighting:

the relay is energised

Not lighting:

the relay is de-energised

3 - BATTERY

 it serves exclusively for power supply of internal clock permanently on even in case of power error, any other saved function / parameter setting will safely be 

saved without battery and power supply, too

Concerning battery type, see technical data.

4 - FLATCABLE CONNECTOR

 connector for frontpanel's flatcable

Y

ou shall not leave the box cover hanging on the flat multicore cable in any case!

5 - SUPPLY LED

 LED signalling the presence of low voltage supply

6 - B1 FUSE

 fuse of low voltage part, for its value see the technical data

The LED lights in case of error of fuse.

7 - PC KEYBOARD

 

connecting of a standard PC keyboard by PS2 connection, which enables control to be set even more easily

8 - AUX.CONNECTOR

 serves for connecting auxiliary panels to the control unit

4

Fig. 4A: Control Board - EVO1

Fig. 4B: Control Board - EVO2

Содержание EVO1

Страница 1: ...lation Manual Important Notice 3 Type Variants 3 Frontpanel 4 Control Board 4 Connecting Power Up 5 Software Settings 8 Software Main Screen 8 Software Main Menu 9 Software Zone Menu 12 List of Parameters 15 Technical data 15 Index 16 ...

Страница 2: ...EVO SZUTM_A5B010AEN Fig 1 Fig 2 Fig 3 ...

Страница 3: ...all be handed over to the applicable collection point By ensuring of this product is disposed correctly you will help prevent potential negative consequences for the environment and human health Recycling materials helps preserve resources of the earth TYPE VARIANTS EVO1 heating controller unit for one zone FUNCTIONS industrial temperature controller unit for several types of burners controlling o...

Страница 4: ...connections can easily be performed by using dismantling terminal blocks and terminal block functions marked on panel by pictures if possible You shall not leave the box cover hanging on the flat multicore cable in any case When installing you shall provide a support to the box cover or have it removed by disconnecting the easily dismantling line terminals 1 TERMINAL BLOCKS see their detailed desc...

Страница 5: ... phase output switched by Stage1 relay in case of a single stage burner or radiator the phase wire of burner radiator shall be connected here in case of a double stage burner or radiator the phase wire of first stage of burner radiator shall be connected here Stage2 output phase output switched by Stage2 relay in case of a single stage burner or radiator it is not in use shall be left free in case...

Страница 6: ...en the possibility to use Optimisation heating up mode Connection of auxiliary panel You shall exclusively use auxiliary panels which being compatible with EVO control unit information thereof can be obtained in the description of complementary panel Insert complementary panel into 10 pin serial connector of control unit as shown in figure Fig 2 and check then correctness of connection Power up th...

Страница 7: ...EN 7 Fig 5C Connection of Terminal Blocks EVO3 Fig 5D Connection of Terminal Blocks EVO4 ...

Страница 8: ...idays during both optimisation heating up and overtime heating up the remaining duration will be displayed In case of manual mode the manual mode type selected will be displayed 4 INNER TEMPERATURE the temperature measured within zone will be displayed 5 OUTTER TEMPERATURE displays the temperature measured by outside heat sensor of system if mounted 6 KEY SYMBOL displays actual access level which ...

Страница 9: ...setting date time language etc which are not in close relationship with individual heating zones Zone settings can be performed from zone menu according to Chapter Zone menu The figure shows the structure of main menu system Fig 6 and accessibility of each setting The description of numbered menu points can be found below figure 9 Fig 6 Main Menu System page1 ...

Страница 10: ...ncy to display zone costs 8 ENERGY COST unit price of energy calculated from fuel price and specific heat EUR kWh Calculation for oil unit price of oil EUR kg caloric power MJ kg 3 6 MJ kWh Calculation for gas unit price of gas EUR m3 caloric power MJ m3 3 6 MJ kWh 9 LANGUAGE SELECTION setting of controller language 10 PC KEYBOARD setting the layout of PC keyboard to be connected 11 KEYBOARD BEEP ...

Страница 11: ... notofication there will be no alert when service date reached Message notification when service time reached an alert box will be opened periodically to alert to service needed Message sound notification when service time reached there is an acoustic sound together with opening alert box 18 OUTTER SENSOR setting whether an external thermal sensor connected to system or not 19 OUTTER SENSOR CORREC...

Страница 12: ...between zones without leaving menu which enables significantly quicker setting of zones or inspection zone settings Miscellaneous other general settings which are relating to controller unit or to the whole of heating system can be carried out in main menu according to Chapter Main menu The structure of zone menu system can be seen in figure Fig 7 together with accessibility of individual settings...

Страница 13: ...to consideration during which holiday temperature is permanently maintained When temperature optimisation function set night time temperature can earlier be changed against daytime temperature than set in weekly time program optimised heating up mode so as to reach daytime temperature in desired time In night time mode one hour of daytime temperature period can be requested by actuating push butto...

Страница 14: ...8 INNER SENSOR CORRECTION setting temperature correction caused by the location where internal heat sensor of zone installed the value set here shall be deducted added from to real temperature measured by heat sensor 9 HYSTERESIS setting switching hysteresis of burner radiator 1st stage hysteresis switching hysteresis of stage1 of burner radiator see fig 8 2nd stage delta T switching hysteresis of...

Страница 15: ...age 2 10 00 600 00 sec 14 tvondelay Delay time of fan start 0 00 10 00 sec 15 tvoffdelay Delay time of fan shut off 0 00 20 00 min 16 tvoffmin Minimal idle time of fan 10 00 600 00 sec 17 Burner power in stage 1 0 50 1000 00 kW 18 Total burner power 0 50 1000 00 kW 19 Correction of internal clock 22 20 22 20 sec day Table 1 List of Parameters TECHNICAL DATA Description of product EVO1 heating cont...

Страница 16: ...ard beep Language selection Mainmenu 9 Settings Language keyboard Language selection Login Mainmenu 23 Login Monthly costs Zonemenu 21 Zone info Costs Monthly costs Night temp Zonemenu 6 Settings Temperatures Night temp Notification Mainmenu 17 Service menu Servicing datas Next servicing Notification Outter sensor Mainmenu 18 Service menu Misc settings Outter sensor Outter sensor correction Mainme...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: