Description of operation of the power sources  

9

The contents of this chapter are of vital importance and the-

refore necessary for operation of the warranties. The manu-

facturer accepts no liability if the operator fails to observe

the above precautions and instructions.

4.4 WELDER PRESENTATION

Genesis 60 and Genesis 90 are handy compact plasma cut

power sources. 

Genesis 60 and Genesis 90 use compressed air only, which can

be supplied by an ordinary compressor or a suitably sized cen-

tral system; they are able to inexpensively perform good quality

cuts up to a thickness of 20 mm for Genesis 60 and 30 mm for

Genesis 90 on carbon steel while maintaining limited weight

and dimensions.

The excellent performance/weight ratio has been made possible

by use of the inverter technology, common to the whole of the

Genesis range. The current is stable and insensitive to variations

in mains voltage, in the height of the cutting arc, in the feed

speed and in the thickness of the metal  to be cut. The Genesis

60 and Genesis 90 are provided with an automatic pilot arc re-

striking circuit which ensures optimal cutting of metal grille

structures. 

The welder features safety systems that inhibit the power circuit

when the operator comes into contact with live parts of the

machine, and controls to reduce the wear on the electrode and

nozzle when the cutting arc is struck. The pilot arc is struck by

means of a high frequency voltage discharge which is automati-

cally disconnected once the operation has been performed,

thus limiting the emission of radio interference in the rest of the

cutting procedure. 

The following are provided on the power source:  

- a torch fitting 

- a ground socket 

- a front panel 

- a rear panel.

4.4.1 Front control panel

Fig.1

*

L1 : Voltage warning light green led.

Comes on with the start switch (Fig.2) "

I1

" in position "

I

" and

indicates that the plant is on and there is voltage.

* L2: Power output light red led.

Comes on when the arc is sparked, both during cutting and

when not cutting, and goes out as soon as the arc finishes. 

* L3: torch cap alarm green led.

Means that the torch cap has not been properly tightened.

The generator has no power output.

* L4: compressed air alarm green led.

Means that the pressure of compressed air is below 3 bar, too

low for proper functioning. The generator has no power output.

*

L5 : Safety device warning light  yellow led

.

lndicates that the safety devices like thermal cutout.

With "

L5

" on, the power source remains connected to the

supply mains, but does not supply output power. 

"

L5

" remains on until the fault has been removed and in any

case until the inner temperatures are not within the normal

values; in this case it is necessary to leave the power source

on to exploit the operating ventilator and reduce the time

when it is not active.

*  E1: Encoder for setting the cutting current.

Allows you to continuously adjust the cutting current. This

current stays unchanged during cutting when the supply and

cutting conditions vary within the allowed ranges.

* T1 : VOLT-AMP reading selection key.

Its permits display of either the welding voltage or current on

DISPLAY “D1”. 

If 

LED “V”

is on, the last voltage reading taken during the last

cutting operation is displayed. If you do not begin cutting

within 5 sec. the system automatically switches to A, displa-

ying the set current. Vice versa if you begin cutting within 5

sec., the voltage is displayed during the entire cutting opera-

tion after which the reading remains displayed for a further 5

seconds. 

If 

LED “A”

is lit up on display D1, the set or cutting current is

displayed if the operation is in progress. The display is main-

tained for 5 seconds after the end of the operation.

* T2:  gas test pushbutton.

Allows impurities to be removed from the compressed air cir-

cuit and preliminary capacity and pressure settings to be

made with no power output.

* D1 :

displays the set current, cutting current and cutting vol-

tage or the letters GEN (at switch-on) and ERR (blinking in the

event of an alarm).

* D2 :

displays the air pressure value for the cutting process. At

switch-on it displays the software version. In the event of an

alarm, it displays the alarm code in blinking mode:

01   IIC error

02 torch cap open

03  air pressure too low

11 thermal switch 

In the event of an alarm, the operating conditions

are restored only if the cause is removed.

Содержание Genesis 90

Страница 1: ...REPAIRS MANUAL Genesis 90 E N G L I S H...

Страница 2: ...INSTRUMENTS AND CONVENTIONS FOR PERFORMING DIAGNOSIS AND REPAIR 5 4 DESCRIPTION OF OPERATION OF THE POWER SOURCES 7 5 OPERATING PRINCIPLE BLOCK DIAGRAM 15 6 WIRING AND CONNECTION DIAGRAM 16 7 PC BOARD...

Страница 3: ...purchaser must follow the directions contai ned in the above manual Failure to do so will exempt Selco from all liability The operations described in this manual require the use of a digital multimet...

Страница 4: ...ne must be unplugged from the power supply Wait approx one minute before carrying out work on the internal parts as the capacitors may be loaded at high voltage CAUTION When taking measurements remem...

Страница 5: ...gonal nuts complete set of blade screwdrivers complete set of Phillips screwdrivers complete set of Allen keys Phillips torque screwdriver for M3 screws with tigh tening torque adjustable range from 1...

Страница 6: ...ymbols will be used in the same way AC or DC voltage measurement multimeter in voltmeter mode Resistance measurement multimeter in ohmmeter mode Current measurement ammeter clamp or shunt multi meter...

Страница 7: ...plosive powders gases or vapours are present Do not perform welding cutting operations on or near contai ners under pressure Don t use this machine to defrost pipes 4 1 3 Protection against fumes and...

Страница 8: ...working all the access and operating doors and covers must be closed and fixed The welding power source must not be modified in any way WELDING AND CUTTING CABLES The welding cutting cables must be ke...

Страница 9: ...arm green led Means that the torch cap has not been properly tightened The generator has no power output L4 compressed air alarm green led Means that the pressure of compressed air is below 3 bar too...

Страница 10: ...s been removed from the packing the power source is supplied with an extendible belt which can be used to move it in the hand or on the shoulder 4 6 INSTALLATION Choose an adequate installation area b...

Страница 11: ...rking cor rectly and some display If operating faults occur in the generator it will be inhibited until normal operating conditions are restored Press the gas test pushbutton T2 in Fig 1 in order to r...

Страница 12: ...the plasma arc made very hot and highly concentrated by the design of the torch transfers onto the conductive piece to be cut closing the electrical circuit with the generator The material is first me...

Страница 13: ...00 500 14000 3200 1200 900 400 21000 7200 3200 1400 900 400 250 200 Thickness mm 1 3 1 3 6 5 10 15 1 3 6 5 10 15 20 25 30 Current A 30 30 60 60 60 60 60 90 90 90 90 90 90 90 90 Speed mm min 5700 1000...

Страница 14: ...e speed must be adjusted so that the outflow of the arc below the workpiece is perpendicular 5 10 degrees of slope are acceptable A slow speed start is advisable to prevent spray of material which cou...

Страница 15: ...r 5 Snubbing inductor 6 Primary current transformer 7 Resonant inductor 8 Power transformer 9 Secondary power rectifier 10 Pilot arc IGBT 11 Hall effect probe cutting current 12 Output filter 13 Auxil...

Страница 16: ...ent fast protection circuit Auixiliary power supplies switching frequency derived from inverter logic System synchronization for noiseless welding arc audible subarmonic frequency generation avoided i...

Страница 17: ...6 WIRING AND CONNECTION DIAGRAM 6 1 Genesis 90...

Страница 18: ...Wiring and connection diagrams 17 6 2 Connections for torch FRONT VIEW 1 torch cap protection 2 common protection and torch button 3 trigger 7 8 pilot arc...

Страница 19: ...18 PC boards location 7 PC BOARDS LOCATION...

Страница 20: ...PC boards location 19...

Страница 21: ...therefore the machine is correctly powered Torch cap missing LED GREEN It indicates that the torch end tip is missing Always off when the torch is working and connected to the generator correctly When...

Страница 22: ...the ventilation effect Indicat 01 02 03 11 13 Description of diagnostic indications 21 Type of error Front panel memory error Torch not correctly assembled connected Low air pressure Overtemperature...

Страница 23: ...circuit supply 24Vdc Power supply not used 24Vdc Power supply not used 26Vdc Main positive auxiliary power supply 10Vdc P logic power supply 20Vdc Main negative auxiliary power supply 12Vdc Primary L...

Страница 24: ...8 3 Thermal devices connectors locations Description of diagnostic indications 23...

Страница 25: ...24 Description of diagnostic indications...

Страница 26: ...nfirms the new value The table shows that some parameters have no values associated to them by selecting one of these parameters and pressing the Parameters button the associated operation is performe...

Страница 27: ...switched off instrumental check on power parts and any boards that may be faulty if faults are found repla ce the parts with equivalent spares be careful of any configurations calibrations to be perfo...

Страница 28: ...e power supply the main switch is live regardless of its status open or closed It is therefore important to unplug the machine before touching any internal part of the power source Wait approx one min...

Страница 29: ...r sources for the various machine circuits see table on following page fan and gas solenoid valve power supply the signals for the Hall probe and torch button pass through this board The weld switchin...

Страница 30: ...P7 CNB 9 TP8 CNB 9 CN7 2 CN7 1 CN1 4 CN1 5 CN1 1 CN1 5 CN1 2 CN1 5 CN5 7 CN5 9 CN5 8 CN5 9 TP26 TP21 CN8 2 CN8 1 TP22 TP21 CN8 6 CN8 5 400Vac 15 400Vac 15 400Vac 15 560Vdc 15 12Vdc 30Vdc 24Vdc 24Vdc 2...

Страница 31: ...ms over under voltage phase lack not used power supply output Negative auxiliary power supply inverter control logic welding logic panel logic Hall probe Microprocessor logic power supply front panel...

Страница 32: ...e electronic boards current calibration 31 Functional part Input fuse Output fuses Driver Power switches Power diodes Generator Mode OFF OFF OFF OFF OFF Component F1 F2 F3 F4 F5 F6 F7 F8 F9 MF3 MF1 MF...

Страница 33: ...on above NOTE Values below are referred to each sigle component tested alone without any connection any other other value in this page is referred to normal conditions with all connections correctly m...

Страница 34: ...Thermal switches Inverter input high voltage Output voltage Generator Mode OFF OFF OFF ON STICK ON STICK Component IG1 IG2 D1 D2 D3 D4 D5 D6 MF1 G E MF2 G E IG1 or IG2 Test point C2 E1 C1 E2 C2 E1 B1...

Страница 35: ...y source at low voltage and limited current protected against short circuits switching the generator everything works normally but the output voltage reading must be appropriately scaled e g by connec...

Страница 36: ...Inverter Enabled power out L3 POT signal that is Inverter Disabled due to microprocessor logic command coming from Front Panel PC Board Note fuses are located on Aux Power Supply PC board 15 14 271 se...

Страница 37: ...rd performs the following functions driving of resonant inverter power components Soldered jumpers factory setted all located on solder side of PC Board K1 CLOSED K2 CLOSED K3 CLOSED K4 CLOSED K5 CLOS...

Страница 38: ...terface relays for the RL1 torch button and RL2 torch protection WARNING PZ_PE must always be earthed Note before carrying out this operation disconnect CN2 from the HF 15 14 192 board so as to avoid...

Страница 39: ...ions with all connections correctly made Unless specified otherwise all the measurements must be taken with the boards fitted together with their connections 38 Description testing and replacement of...

Страница 40: ...off This test must therefore be performed with FN1 and FN2 disconnected Unless specified otherwise all the measurements must be taken with the boards fitted together with their connections Descriptio...

Страница 41: ...FF 3 OFF 4 ON NOTE dip switch 3 being ON allows bypassing the alarm generated by the pressure switch in the event of air pressure being non existent or lower than 3 bar this operating mode can make te...

Страница 42: ...arc solenoid valve HF control Pilot arc control Cutting current sensor Inverter power breakover Reference for inverter control Output voltage Generator Mode ON ON ON ON ON ON ON ON ON ON ON ON NO LOA...

Страница 43: ...ccurate measurement of actual output current is required You are advised to use an ammeter clamp with class 2 minimum rating accurately calibrated calibration certificate issued no more than 12 months...

Страница 44: ...anges by adju sting P3 trimmer adjust P3 trimmer on resonant inverter control PCB 15 14 152 until value showed by external clamp amme ter matches the value showed on control panel this value is the re...

Страница 45: ...11 AVAILABLE SPARE PARTS 44 Available spare parts 56 01 090 GENESIS 90...

Страница 46: ...lterkarte 15 14 276 20 Resonanzdrosselswule 05 04 208 21 Drosselspule Snubber 15 14 241 22 Einheit Prim rinverter 14 60 069 23 Hintere Plastkatel 01 05 222 24 Resonanzlogikkarte 15 14 298 25 Halterung...

Страница 47: ...SELCO s r l Via Palladio 19 35010 ONARA DI TOMBOLO PADOVA ITALY Tel 39 049 9413111 Fax 39 049 9413311 http www selcoweld com E mail info selco it SELCO 2 Via Macello 61 35013 CITTADELLA PADOVA ITALY...

Отзывы: