4.4.2 Rear control panel
*
I1: Off/On switch
Turns on the electric power to the welder.
It has two positions, "
O
" off, and "
I
" on.
* With the I1 switch in the "I" on position, the welder is
operational.
* The welder is connected to the mains supply even if the I1
switch is in the "O" position, and therefore there are elec-
trically live parts inside it. Carefully follow the instruc-
tions given in this manual.
* 1 : Supply cable.
* F1 : Pressure adjustment knob
* P1 : Filter unit air connection 1/4 ” coupling
* F : Air filter unit
Fig.2
4.4.3 Technical characteristics
G90
Power supply voltage
(50/60 Hz)
3x400V
Delayed fuse
32 A
Rated power
11.98 kW
Cutting current
(x=60%)
90 A
(x=100%)
70 A
Cutting voltage
116 V
No-load voltage
265 V
Pilot arc current
22 A
Gas type
AIR
Operating pressure
5 bar
Flow rate
180 l/min
Torch to be used
81.20.037
Protection class
IP23C
Insulation class
H
Construction regulations
EN60974-1
EN60974-10
Dimensions (LXPXH)
215x596.5x406 mm
Generator weight
25 Kg
Above data are referred to environment al 40°C
4.5 TRANSPORT - UNLOADING
Never underestimate the weight of the equip-
ment, (see technical characteristics).
Never make the cargo pass or leave it suspended
over people or things.
Neither let the equipment or the single unit fall,
nor put it down with force.
Once it has been removed from the packing, the
power source is supplied with an extendible belt
which can be used to move it in the hand or on
the shoulder.
4.6 INSTALLATION
Choose an adequate installation area by following
the criteria provided in Section "4.1 SAFETY" and
“4.2 ELECTROMAGNETIC COMPATIBILITY
(EMC)”.
Do not position the power source and the equip-
ment on surfaces with inclination exceeding 10°
with respect to the horizontal plane.
Protect the installation from heavy rain and sun.
4.6.1 Electric connection to the supply mains
The equipment is provided with a single electric connection with
a 5m cable positioned in the rear part of the power source.
Size table of the power source input cables and fuses:
Power source
GENESIS 90
Rated voltage
400 V ±15%
Voltage range
340 - 460 V
Delayed fuses
32 A 500 V
Power supply cable
4x6 mm2
* The electrical system must be made by skilled technicians
with the specific professional and technical qualifications
and in compliance with the regulations in force in the
country where the equipment is installed.
* The welding power source supply cable is provided with a
yellow/green wire that must ALWAYS be earthed. This yel-
low/green wire must NEVER be used with other voltage con-
ductors.
* Verity the existence of the earthing in the used plant and
the good condition of the socket/s
* lnstall only plugs that are homologated according to the
safety regulations.
10
Description of operation of the power sources
WARNING
WARNING
Содержание Genesis 90
Страница 1: ...REPAIRS MANUAL Genesis 90 E N G L I S H...
Страница 17: ...6 WIRING AND CONNECTION DIAGRAM 6 1 Genesis 90...
Страница 19: ...18 PC boards location 7 PC BOARDS LOCATION...
Страница 20: ...PC boards location 19...
Страница 24: ...8 3 Thermal devices connectors locations Description of diagnostic indications 23...
Страница 25: ...24 Description of diagnostic indications...
Страница 45: ...11 AVAILABLE SPARE PARTS 44 Available spare parts 56 01 090 GENESIS 90...