Hints:
-
removing of Auxiliary Power Supply 15.14.271 is not required to perform checks listed above
-
to ease measurements, PZ_- , +12VAUX , PZ_+ signals are electrically connected to CNB/9, CNB/10, CNB/16 respectively.
* Note:
fuses are located on Aux. Power Supply PC board 15.14.271 (see related section below).
Power supply
V1
V2
V3
V4, V5
V6
V7
V8
Unless specified otherwise, all the measurements must be taken with the boards fitted, together with their connections!
Description, testing and replacement of the electronic boards, current calibration
29
Input voltage
Input rectifier
Aux power supplies
Phase lack alarms
Overvoltage alarm
Undervoltage alarm
Fan
Hall probe
Torch trigger
Torch protection
Solenoid valve
low pressure
(pilot)
Solenoid valve
high pressure
(cut)
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
-
PR1 / PR2
+12VAUX = LIT
LVA = LIT
LVB = LIT
LVC = LIT
LVD = LIT
LVE = LIT
LVF = LIT
LU = OFF
LV = OFF
LW = OFF
L_HV = OFF
L_LV = OFF
-
-
-
-
-
-
PZ_U PZ_V
PZ_U PZ_W
PZ_W PZ_V
PZ+ PZ-
CNB/10 CNB/9
TP17 TP16
TP9 TP11
TP10 TP11
TP24 TP21
TP27 TP21
TP23 TP21
TP20 CNB/9
TP19 CNB/9
TP18 CNB/9
TP7 CNB/9
TP8 CNB/9
CN7/2 CN7/1
CN1/4 CN1/5
CN1/1 CN1/5
CN1/2 CN1/5
CN5/7 CN5/9
CN5/8 CN5/9
TP26 TP21
CN8/2 CN8/1
TP22 TP21
CN8/6 CN8/5
400Vac ± 15%
400Vac ± 15%
400Vac ± 15%
+560Vdc ± 15%
+12Vdc
+30Vdc
+24Vdc
-24Vdc
+26Vdc
+10Vdc
-20Vdc
+12Vdc
+12Vdc
+12Vdc
+12Vdc
+12Vdc
+26Vdc
+15Vdc
-15Vdc
+2.2Vdc
Cutting arc (90A)
+5Vdc
0Vdc
+5Vdc
0Vdc
0Vdc
+5Vdc
0Vdc
+24Vdc
0Vdc
+5Vdc
0Vdc
+24Vdc
V1
V2
V3
V4
V5
V6
V7
V8
PT released
PT push
Torch EXT NOZZLE open
Torch EXT NOZZLE closed
ETV dde-energised
ETV energised
ETV de-energised
ETV energised
ETV de-energised
ETV energised
ETV de-energised
ETV energised
Functional part
Input rectifier
Fan
Generator/Mode
OFF
OFF
Component
PR1 / PR2
FT1
Test point
PZ_U PZ+
PZ_V PZ+
PZ_W PZ+
PZ- PZ_U
PZ- PZ_V
PZ- PZ_W
S G
S D
Value
+ 0.5Vdc
+ 0.5Vdc
+ 0.5Vdc
+ 0.5Vdc
+ 0.5Vdc
+ 0.5Vdc
+ 0.7Vdc
+ 0.6Vdc
Notes
Related circuit
Inverter input voltage power supply input
Input voltage alarms (overvoltage, undervoltage, phase lack)
Torch trigger and protection
Not used
Main positive auxiliary power supply (inverter control logic, cut logic, pilto arc logic, panel
logic, Hall probe, thermal alarm, fan, solenoid valve)
Microprocessor logic power supply on front panel
Negative auxiliary power (inverter control logic, welding logic, panel logic, Hall probe)
Fuse*
-
F4
F2
F5, F6
F9
F8
F7
Содержание Genesis 90
Страница 1: ...REPAIRS MANUAL Genesis 90 E N G L I S H...
Страница 17: ...6 WIRING AND CONNECTION DIAGRAM 6 1 Genesis 90...
Страница 19: ...18 PC boards location 7 PC BOARDS LOCATION...
Страница 20: ...PC boards location 19...
Страница 24: ...8 3 Thermal devices connectors locations Description of diagnostic indications 23...
Страница 25: ...24 Description of diagnostic indications...
Страница 45: ...11 AVAILABLE SPARE PARTS 44 Available spare parts 56 01 090 GENESIS 90...