Seiler Evolution Zoom Скачать руководство пользователя страница 19

19

Figure 16: Changing the fuses

LED reliability and lifetime (only for units with LED source)

•  The LED source selected is one of the most reliable light sources in the world today. It has passed a rigorous 

suite of environmental and mechanical stress tests, including mechanical shock, vibration, temperature 

cycling and humidity, and has been fully qualified for use in extreme high power and high current applications 

(paragraph 9.2).

•  Failure rate: very low.
•  Lifetime: lumen maintenance of greater than 70% after 60,000 hours.
•  In case of LED technical issues, please contact the AUTHORIZED TECHNICAL ASSISTANCE.

Replacing a blown fuse

•  Shift the main switch on the control panel to OFF (Figure 5) and disconnect the power plug from socket   

(Figure 8).

•  The fuse holder located on the electrical panel of the column covers 2 safety devices inside (Figure 8) Open 

the cover and replace the blown fuse. Only 5A fuses shall be used (2 spare components are supplied).

Repairing the equipment

•  To ensure an extended lifetime of the Seiler Evolution Zoom Microscope , the user is encouraged to 

periodically consult Seiler Instrument to check the condition of the equipment and perform maintenance 

as necessary. The AUTHORIZED TECHNICAL ASSISTANCE are reserved the right to repair or to perform 

periodical maintenance or part replacement, whenever necessary.

•  In the event of any defect in The Seiler Evolution Zoom Microscope , consult Seiler Instrument immediately 

after receiving the product.

CAUTION:

 The equipment and its parts must be discarded according to the applicable environmental and 

discarding regulations. Always check if the device component presents risks to the personnel and the environment, 

in order to ensure safety discard, in accordance with the applicable laws (Chapter 11).

PLEASE NOTE:

 Do NOT ship 

the Seiler Evolution Zoom Microscope 

to the supplier, without consulting the 

AUTHORIZED SEILER DISTRIBUTOR.

Содержание Evolution Zoom

Страница 1: ...this manual are for illustration purposed only and may vary according to the version of the device purchased The information contained in this manual is subject to change without notice Please contact...

Страница 2: ...AND HYGIENE 18 Switching Bulbs During Use Only For Units With Halogen Bulb 18 Replacing A Burnt Out Bulb Only For Units With Halogen Bulb 18 Led Reliability And Lifetime Only For Units With Led Sourc...

Страница 3: ...3 WARNING 27 TERM OF WARRANTY 27 CONTACT INFORMATION 27 OWNERS RECORD 28 NOTES 28 WARRANTIES 29 30 CERTIFICATES OF COMPLIANCE 31 32 DECLARATION OF CONFORMITY 33 34...

Страница 4: ...ards We also ensure all optical components have undergone an anti reflective multi layer treatment guaranteeing the efficiency of the system and enhancing the longevity of all of our products Along wi...

Страница 5: ...and Components The Seiler Evolution Zoom Microscope is divided into modules Figure 1 Figure 1 Modules of the Seiler Evolution Zoom Microscope Atlantico Systems Ltd 34 Oldfield Kingston Galway Ireland...

Страница 6: ...raphic Arm The pantographic arm is the structural module between the illumination box and the optical module Optical Module The optical module comprises the objective lens continuous magnification sys...

Страница 7: ...7 ATTENTION Avoid overly tightening the knobs Figure 2 Main elements of the Seiler Evolution Zoom Microscope Figure 3 Optical module with binocular head...

Страница 8: ...8 Figure 4 Multifunctional pedal Figure 5 Control panel Figure 6 Joystick for adjusting zoom light level and focus...

Страница 9: ...nstrument shall NOT be liable for any other type of procedure NOT set forth herein used to install or assemble this product nor shall be liable for any misuse of tools Unpacking The Seiler Evolution Z...

Страница 10: ...ith a 7 32 hex wrench 3 Place the two spacers between the plate and the stabilizer bar with the white pads facing you and bolt it on with the two bolts supplied with the spacers 4 Add outer bolt to le...

Страница 11: ...t sunlight In places where ventilation devices and air conditioners blow directly on the device In places where heating devices directly affect the equipment In unsafe places In dusty environments In...

Страница 12: ...ice can be connected at any level of voltage ranging from 90 240V 50 60 Hz adjusted automatically to properly work in these ranges Make the connection between the multifunctional pedal cable and the e...

Страница 13: ...can be set using the Knob to raise or down the swivel casters so as to place them on a horizontal plane Figure 10 To adjusting the optical system to a specific position make sure the swivel casters ar...

Страница 14: ...l module or the microfocus motor covers as a rest or support to pull push raise or move the equipment Only use the column or its handle to move the unit Figure 10 Swivel casters with brakes Figure 11...

Страница 15: ...to tighten the fixing Knob of the pantographic arm Switching on the Unit Connect the AC Power Cable to the Electrical panel and to the grounding electrical socket Electrical Panel External Connection...

Страница 16: ...tem 5x to 30x is controlled by the multifunction pedal or the joystick Figure 4 and Figure 6 To select the magnification simply activate the Adjustment Pedal or the Joystick for increasing or reducing...

Страница 17: ...imit is reached Figure 5 To center X and Y axes at the same time press the center button located at the control panel Figure 5 Using the inclinable binocular head The Inclinable Binocular Head can be...

Страница 18: ...plug from socket Figure 8 Check whether the equipment is hot If so wait a few minutes approximately 15 minutes until it is cooled Loosen 4 screws holding the illumination box cover and remove it Figu...

Страница 19: ...he cover and replace the blown fuse Only 5A fuses shall be used 2 spare components are supplied Repairing the equipment To ensure an extended lifetime of the Seiler Evolution Zoom Microscope the user...

Страница 20: ...module can be sterilized in autoclaves or ovens Control components such as buttons may be shielded from contact by a plastic film Caution The equipment must be switched off and disconnected from the...

Страница 21: ...ionally When this accessory is connected to the image splitter and the camera adapter it is possible to display images on a monitor and also record the data generated Video camera adapter As mechanica...

Страница 22: ...y the zoom adjustment function of the multifunction pedal Figure 4 Filters If required it is possible to use two types of filter that nullifies the light passage in 810nm or 532 nm wavelength They are...

Страница 23: ...the zoom version 5X to 30X continuous Illumination provided by optical fibers Illumination field 50 mm Illumination brightness on the working surface 90 000 lux 10 CLASSIFICATION AND NORMS Protection...

Страница 24: ...d Do NOT expose the equipment do direct sunlight Keep the device and its surroundings clean The equipment shall be stored indoor Discard The equipment s discard or its parts it must be accomplished ac...

Страница 25: ...ce continues switching off randomly call Seiler Instrument Warning Never disconnect the power cable while the device is operating This may cause the internal components to fail or burn Warning Never p...

Страница 26: ...mperature limits Catalog Number Product Serial Number Authorized Representative in the European Community MARKING SYMBOL MEANING Warning consult accompanying documents High Voltage Shock Hazard Degree...

Страница 27: ...is violated Seiler Instrument is NOT liable for personal damage or other injuries resulting from the improper use of the device Seiler Instrument s liability regarding this device and its results is l...

Страница 28: ...28 Owners Record Notes Model Number Serial Number Date Purchased Location Purchased...

Страница 29: ...instruction for the use of the product abuse physical mishandling or natural causes such as flood fire earthquake or other perils as determined by SIC or 2 if any repairs are made by persons unauthori...

Страница 30: ...n for the use of the product abuse physical mishandling or natural causes such as flood fire earthquake or other perils as determined by SIC or 2 if any repairs are made by persons unauthorized by SIC...

Страница 31: ...ss 3433 Tree Court Industrial Blvd St Louis MO 63122 Tel 314 218 6365 Product Tested Evolution Zoom EVO 100 ZLED EVO 100 LEDXY EVO 100 ZLEDXY Tested By ITC Engineering Services Inc 9959 Calaveras Road...

Страница 32: ...ss 3433 Tree Court Industrial Blvd St Louis MO 63122 Tel 314 218 6365 Product Tested Evolution Zoom EVO 100 ZLED EVO 100 LEDXY EVO 100 ZLEDXY Tested By ITC Engineering Services Inc 9959 Calaveras Road...

Страница 33: ...33...

Страница 34: ...34...

Страница 35: ...35...

Страница 36: ...cro seilerinst com www seilerinst com Atlantico Systems Ltd 34 Oldfield Kingston Galway Ireland www atlanticosystems com MEDICAL DIVISION MED8019 Rev 4 March 2019 100 Lauman Lane Suite A Hicksville NY...

Отзывы: