background image

21

 

I-5321-4

 

 

4

-

2

 

 出力停止 

4-2 

SUSPENSION OF OUTPUT LINE

 

     

 

     

各子時計出力ラインおよびロガー出力ライン
の異常時や、電源入力(AC,DC双方)に 
異 常 が 発 生 し た 場 合 に は 次 の 表 示 に な り    
ます。

 

When abnormal condition is detected on the 
output line of secondary clocks or logger output, or 
input 
line of AC/DC power supply, the following status is 
displayed.

 

 

    

     ACCIDENT 

       OUTPUT  STOP 

←→

 UT    01/07/29 
 STP  11:08:32 

       

警報表示と(異常発生)時刻表示は、1秒周期
で交互に表示します。

 

警報表示ランプも1秒間隔で点滅します。

 

 

このとき、各出力系統は以下の通りになりま
す。

 

Display of abnormal status and the current time is 
alternately displayed at interval of one second. 
The ALARM lamp blinks every second as well. 
Each output line will be the following status.

 

 

       

「0

.

5秒子時計出力」

,

「30秒子時計出力」

 

「デジタル信号出力」

 

「ロガー信号出力」

 

「警報信号出力」

 

・・・・停止

 

・・・・停止

 

・・・・停止

 

・・・・停止

 

 

0.5sec secondary clock

,

30sec secondary clock

 

Digital signal output

 

Logger signal output

 

Alarm signal output

 

・・・・

 Stop 

・・・・

 Stop 

・・・・

 Stop 

・・・・

 Stop

 

 

             

 

 

異常原因を取り除いてから

 

RESTART

 

キーを押して、初期設定の要領で復帰させて
ください。

 

After fixing the cause of trouble, push 

RESTART key to initialize the system. 

 

   

 

       

 

 

Содержание QC-6M5

Страница 1: ...arine Master Clock QC 6M5 Before putting your QC 6M5 to use please be sure to read this manual carefully as it has been prepared to assist in the installation operation and maintenance of your QC 6M5...

Страница 2: ...eglect of other reasonable care and servicing due to be done by the owner irrespective of such instructions and failure due to deliberate actions or gross negligence or accident or caused by changes m...

Страница 3: ...tion Switches 2 3 Operation NORMAL OPERATION 3 1 Switch the display of UT and LT 3 2 0 SEC ADJUSTMENT 30SEC ADJUSTMENT 3 3 AUTOMATIC TIME ADJUSTMENT 3 4 MANUAL LT ADJUSTMENT 3 5 AUTOMATIC LT ADJUSTMEN...

Страница 4: ...fect safety or performance of this equipment Failure to follow this instruction may lead to a risk of electric shock or fire Repair should be left to the care of your SEIKO agent or dealer Prohibition...

Страница 5: ...clock to a wall surface with four installation holes Installation dimensions are indicated in Fig 1 6mm dia bolts are suitable Panel mounting type Fix the clock in place with bolts after processing t...

Страница 6: ...3 Caution Earth terminal should be grounded as in fig 3 to protect the master clock form inductive interference SECONDARY CLOCKS L N DC24V IN AC IN 85 250 LOGGER AL 24V COM 0 5S OUT COM ADV REV 30S OU...

Страница 7: ...heck on polarity of wires connected to the secondary clocks and power supply Synchronize the time of the master clock and the monitor clock to secondary clocks Set the second hand of the master clock...

Страница 8: ...ted as two times of the above table The maximum output capacity for 2 hands secondary clock is 1560mA Max 130pcs The maximum output capacity for 3 hands secondary clock is 240mA Max 20pcs The maximum...

Страница 9: ...back one input frame or displaying page To decrease the displayed numerals To increase the displayed numerals To forward input frame or displaying page to next To enter the input numerals and the pag...

Страница 10: ...isplay In case of RESTART operation it will display the data right before the restart button is pressed The following screen is displayed 0 5sec secondary clock stop Manual adjustment 30sec secondary...

Страница 11: ...Minute 00 0 59 5 for Second decimal should be 0 or 5 However any input which does not exist example 30 February is ignored and the leap year is automatically adjusted Please move the cursor to by key...

Страница 12: ...llows 0 5sec secondary clock running 30sec secondary clock stop Please push ENTER when the input of LT is correct LT starts Go to the next step To re enter the input move the cursor to by key to get t...

Страница 13: ...ime of the hands position is correct 30sec secondary clock starts to move Go to the next step To re enter the input move the cursor to by key to get the former screen During the adjustment the display...

Страница 14: ...in 30 seconds OPERATION OF 0 SEC ADJUSTMENT ADJUSTMENT WHEN THE CLOCK LOSES 0 5sec secondary clock running 30sec secondary clock running Under this status when 0 SEC ADJ is pushed it becomes the follo...

Страница 15: ...J is pushed it becomes the following display 0 5sec secondary clock adjustment fast moving 30sec secondary clock adjustment fast moving 0 5 sec secondary clocks and 30 sec secondary clocks will be adj...

Страница 16: ...rk will be on when it is ready to receive a signal from GPS unit Automatic TIME adjustment by GPS to the internal clock is to be executed once a day from the time of 23 30 00 to 23 50 00 UT on the mas...

Страница 17: ...play to LT by At the display on LT push 20 After the above operation push 1 five times The display of PUSH and ENTER is alternately displayed at cycle of one second Push key 30 sec secondary clocks wi...

Страница 18: ...ustment located on the Printed Circuit Board LT on the master clock will be automatically adjusted in accordance with the time of LT from an external GPS unit Before Automatic LT Adjustment The ship m...

Страница 19: ...owing displays Each status of the illumination the AC power supply and the DC power supply is displayed from the left end The display changes as follows when the DIMMER key is pushed within five secon...

Страница 20: ...LCD simultaneously 4 1 4 1 RESUMED FROM POWER FAILURE When the power is resumed from failure it becomes the following display The ALARM lamp blinks every second The output line will be the following s...

Страница 21: ...splayed Display of abnormal status and the current time is alternately displayed at interval of one second The ALARM lamp blinks every second as well Each output line will be the following status 0 5s...

Страница 22: ...ay of abnormal status and the current time is alternately displayed at interval of one second The ALARM lamp blinks every second as well Each output line will be the following status 0 5sec secondary...

Страница 23: ...d logger signal are output via circuit of Transistor open collector Sample of connection 100mA 150mA DC24V 5V Output Voltage less than 100mA ALARM less than 150mA LOGGER Relay Relay contact Arc exting...

Страница 24: ...After fixing the cause push RESTART key 0 5sec secondary clock and 30sec secondary clock are not synchronized Wrong operation of time synchronization Operate correctly Tripping of DC NFB Overload Sho...

Страница 25: ...25 I 5321 4 EXTERNAL VIEW...

Страница 26: ...26 I 5321 4 MASTER SECONDARY RS 422 NMEA0183 RS 422 NMEA0183 RS 232C...

Страница 27: ...wired system RS 422 One port Based on NMEA0183 Logger signal output Five wired system One port 150mA or less in total 24V COMMON 30 second polarized pulse output 30 second polarized pulse output Signa...

Страница 28: ...N HUGHES NETHERLANDS LTD Klompenmarkerstraat 64 3194 DC Hoogvlit Rotterdam The Netherlands Tel 31 10 4167622 Fax 31 10 4167218 Telex 26545 OBMAR NL KELVIN HUGHES LTD New North Road Hainault Ilford Ess...

Страница 29: ......

Страница 30: ...I 5321 4 URL http www seiko sts co jp...

Отзывы: