SEQUENCER CONTROLLER
WITH OR WITHOUT
DIFFERENTIAL PRESSURE SWITCH
Technical notice
FI 72.0297.1016E
Page 6
ADJUSTMENTS AND RUNNING
The various parameters are set as follows:
- Press the « SELECT » button until the yellow led « menu » lights up opposite the parameter to be set and
operate the buttons « + » and « - » to obtain the desired value.
- Then return to the “CYCLE” position (or “pressure reading” position if it’s equipped with the DP) using the
« SELECT » button. Each parameter is recorded in a memory by moving to the following step or on automatic
return to the “CYCLE” position (or « pressure reading » position if it’s equipped with the DP).
Comment:
- The return to the “CYCLE” position (or “pressure reading” position if it’s equipped with the DP) is automatic
after 30 seconds (unless in « cycle » position).
- Each parameter can be viewed at any time during the operating of the device.
The visualisations 1 to 7 and 13 are only used if the sequencer is equipped with the DP.
1) DP measurement view:
Display the DP measurement.
If there is a fault, alternating display of the type of fault.
If pressed, display of nxx with xx = EV will be actuated at the next blast
If cleaning is in course, rapid flashing of the led of the menu opposite the corresponding time.
If manual operation is in course or fan stoppage cycles are in course, the menu led opposite the fan/manu
flashes rapidly.
If accelerated cleaning is active, the led-menu opposite the T2A threshold flashes rapidly.
Note: For the version 0-999daPa, if the dP measurement exceeded the scale of the sensor, the
system displays
« --- »
Not active without
pressure switch