5
List of Figures
Figure 1 Model MR-400 Single Loop (SLC) Fire Alarm Control Panel .........................................
11
Figure 2 MR-400 Mechanical Installation Instructions and Dimensions .......................................
16
Figure 3 Port and Jumper Locations on Main Board ....................................................................
18
Figure 4 Jumper on back of display .............................................................................................
20
Figure 5 Main Board with all Modules Installed ............................................................................
21
Figure 6 Installing the PR-300 Polarity Reversal and City Tie Module ........................................
22
Figure 7 MGC-3000 Configurator Date and Time Settings ..........................................................
24
Figure 8 Enabling the Positive Alarm Sequence ..........................................................................
33
Figure 9 Operation Menu .............................................................................................................
37
Figure 10 LED Indicators and Control Buttons ...............................................................................
50
Figure 11 Numeric Keypad ............................................................................................................
51
Figure 12 Wire Routing ..................................................................................................................
58
Figure 13 Addressable Loop Wiring - Class B ...............................................................................
59
Figure 14 Addressable Loop Wiring - Class A ...............................................................................
59
Figure 15 Addressable Loop Wiring - Class X ...............................................................................
60
Figure 16 NAC Circuit – Class B Wiring .........................................................................................
61
Figure 17 NAC Circuit – Class A Wiring .........................................................................................
61
Figure 18 RTI-1 Common Remote Trouble Indicator Wiring ..........................................................
62
Figure 19 Wiring the Dialer ...........................................................................................................
63
Figure 20 Connecting an MR-400 FACP to a 3G4010CF Interface Device outside Canada .........
64
Figure 21 Connecting an MR-400 FACP to a SLE-LTEV or SLE-LTEA Interface Device outside
Canada ..........................................................................................................................
65
Figure 22 Wiring the PR-300 Polarity Reversal and City Tie Module ............................................
66
Figure 23 Main Power Supply Wiring and Connections .................................................................
68
Figure 24 Supervision of Auxiliary Supplies ...................................................................................
69