17
CENTRAL FORCED AIR KIT
The knock-outs provided on the sides of the HE43-1 allow the connection of insulated flexible pipe which
enables you to heat adjacent rooms up to 50 feet from the fireplace.
The ducting system must be installed as described below :
1.
Fix the adaptor at the side of the fireplace by twist-locking the adaptor to the fireplace. You can use
more than one outlet on the fireplace (figure 9).
2.
Attach the 5" flexible pipe, using the collars provided.
Important: Make sure that the plastic
wrapping around the flexible pipe will not be in contact with the fireplace
.
3.
Route the flexible pipe to the chosen location. The ducting system can be installed either in an upper
room or in a lower room.
4.
Attach the flexible pipe to the fan, using the collars (figure 10a).
5.
Fix the decorative grill fan adaptor to the fan.
6.
Attach a standard 3" x 10" grill to the adaptor.
7.
Install the
blower thermostat
in that part of the house to be heated by the hot air duct. Do not install the
blower thermostat
in the room where the fireplace is located. A
cooling thermostat
can be installed in
the same room as the unit. This thermostat will turn on the blower when the room where the fireplace is
located becomes too hot.
This option requires electricity. Make sure that the connections to the fan have been made according to the
local codes and comply with their requirements
Figure 10a
Figure 9