background image

                                                                           

 

 

60

5

 

WEB OPERATION  

5.1

 

General Introduction  

The device web provides channel monitor menu tree, search, alarm setup, system setup, PTZ 
control and monitor window. 

5.1.1 Preparation 

Before log in, please make sure: 

z

  PC and NVR connection is OK. 

z

  You have set PC IP address, NVR IP address, subnet mask and gateway. (Please set the IP 

address of the same section for the PC and NVR. Please input corresponding gateway and 
subnet mask if there are routers.) This series product max supports 4 network adapters. The 
default setup is eth1:192.168.1.108, eth2:192.168.1.101, eth3:192.168.1.102 and 
eth4:192.168.1.103.  

z

  Use order ping ***.***.***.***(NVR IP address) to check connection is OK or not.  

 

5.1.2  Log in  

Open the IE and then input the NVR IP address in the address column.  
For example, if your NVR IP address is 10.10.3.16, then please input http:// 10.10.3.16 in IE 
address column. See Figure 5-1. 

 

Figure 5-1 IE Interface  

System pops up warning information to ask you whether install webrec.cab control or not. Please 
click yes button. 
If you can’t download the ActiveX file, please modify your settings as follows. See Figure 5-2. 

Input IP 
address here.

Содержание NVR-LT-128

Страница 1: ...meras This high end unit uses multiple Intel Core i5 processors and has an embedded LINUX operating system for incredible reliability It comes with 4GB DDR3 ram which can be upgraded to 8GB This Netwo...

Страница 2: ...nt Panel 4 2 2 Rear Panel 5 2 3 Alarm Input and Output Connection 6 2 3 1 Alarm Input and Output Details 6 2 3 2 Alarm Input Port 7 2 3 3 Alarm Output Port 8 3 OVERVIEW OF NAVIGATION AND CONTROLS 9 3...

Страница 3: ...HDD Management 47 3 6 2 Abnormity 50 3 6 3 Alarm Output 51 3 6 4 Manual Record 51 3 6 5 Account 53 3 6 6 Auto Maintenance 55 3 6 7 Config Backup 56 3 6 8 RAID Management 56 3 7 Shutdown 57 4 SYSTEM UP...

Страница 4: ...3 Configuration 68 5 3 1 System Information 68 5 3 2 System Configuration 69 5 3 3 Advanced 85 5 3 4 Additional Function 94 5 4 Search 94 5 5 Alarm 97 5 6 About 98 5 7 Log out 99 APPENDIX H TOXIC OR...

Страница 5: ...to be a reference tool for the installation and operation of your system Here you can find information about this series NVR features and functions as well as a detailed menu tree Before installation...

Страница 6: ...examination and repair work should be done by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair 5 Environment The NVR should b...

Страница 7: ...evices z Can generate an email to notify the user when an alarm occurred Network Monitor z Transmit audio video data from the IPC or the NVS connected to the device to the network terminal simultaneou...

Страница 8: ...l standard definition or 16 channel high definition Audio Video Storage Based on 64 bit high performance file system Video Resolution 1080P 720P D1 HD1 CIF QCIF Audio Video Search Based on data librar...

Страница 9: ...3 Working Altitude 60m 3000m Dimensions 516 5mm without the LCD length 485mm With ear 133 2mm L W H Net Weight 20Kg front panel 0 4Kg Installation Mode Standard 19 inch rack installation...

Страница 10: ...e or pull out the power cable may result in device auto restart 2 System HDD Indication light The blue light flashes when system is reading or writing the system HDD In the system HDD there are device...

Страница 11: ...ce an alarm occurred It becomes on via the software detection The alarm includes local alarm no disk and etc 4 Network indication light The network indication light is blue and it flashes when you con...

Страница 12: ...ke sure alarm input mode is grounding alarm input b Grounding signal is needed for alarm input c Alarm input needs the low level voltage signal d Alarm input mode can be either NC normal Open or NO No...

Страница 13: ...and Rx RS232 port Tx is the data output cable and the Rx is the data input cable 2 3 2 Alarm Input Port Please refer to the following sheet for more information z Normal open or Normal close type z Pl...

Страница 14: ...AC 1A Maximum switch power 125VA 160W Maximum switch voltage 250VAC 220VDC Rating Resistance Load Maximum switch currency 1A Between touches with same polarity 1000VAC 1minute Between touches with dif...

Страница 15: ...cter small capitalized and denotation Note For security reason please modify password after you first login Continuous three times login failure will result in system alarm and five times login failur...

Страница 16: ...tem supports 1 4 8 9 16 25 36 64 window output mode Please select the window mode and then select the corresponding channels PTZ Setup The PTZ setup is shown as in Figure 3 5 Please note the commend n...

Страница 17: ...y setup button Please refer to chapter 3 5 7 for detailed information Device management You can use the channel list and the device list to manage the connected remote device The channel list is on th...

Страница 18: ...1 for detailed information 3 2 Main Menu After you logged in the system main menu is shown as below See Figure 3 8 There are total seven icons search Information setting remote device backup advanced...

Страница 19: ...t the Search item Search interface is shown as below See Figure 3 9 Please note the initial version does not support smart search card number search and picture operation Figure 3 9 Please refer to th...

Страница 20: ...n double click the mouse or click the ENTER button to playback zYou can input the period in the following interface to begin accurate search zFile type R regular record A external alarm record M Motio...

Страница 21: ...tion Check the file again you can cancel current selection System max supports to display 32 files from one channel 11 Clip z It is to edit the file z Please play the file you want to edit and then cl...

Страница 22: ...ure 3 10 3 4 1 HDD Information Here is to list hard disk type total space free space and status See Figure 3 11 means current HDD is normal means there is no HDD If disk is damaged system shows as Ple...

Страница 23: ...working HDD Physical port It is to display device connected physical port Type The corresponding HDD property Raid name It is to display RAID HDD name Total space The HDD total capacity Free space The...

Страница 24: ...st System max displays 100 logs in one page It can max save 1024 log files Please use page up down button on the interface or the front panel to view more z Backup Please select a folder you want to s...

Страница 25: ...Here is for you to view some version information See Figure 3 16 Please note the following interface is based on the 128 channel series product and it is for reference only z Channel z Alarm in z Alar...

Страница 26: ...r block one user if you have proper system right Figure 3 17 3 4 6 Remote Device Information Here you can view the channel status of the remote device connection log and network balance information an...

Страница 27: ...can search the IPC log information of the corresponding channel It includes IPC online offline and etc See Figure 3 19 Figure 3 19 Network Balance Here you can view network data transmission speed re...

Страница 28: ...z Time format There are two types 24 hour mode or 12 hour mode z Language Here is to display current language name z HDD full Here is for you to select working mode when hard disk is full There are tw...

Страница 29: ...interval here to synchronize the NVR time and IPC time Note Since system time is very important do not modify time casually unless there is a must Before your time modification please stop record ope...

Страница 30: ...en Channel display You can select system displays channel number or not when you playback Please click set button and then drag the title to the corresponding position in the screen z Snapshot Click s...

Страница 31: ...25 Figure 3 25 Figure 3 26 Figure 3 27...

Страница 32: ...g Click it you can see an interface shown as in Figure 3 31 Here you can set holiday date Check the box it means current channel shall record as your holiday setup Please go to the Period interface to...

Страница 33: ...Figure 3 32 z Network Mode It includes multiple address fault tolerance and load balancing Multiple address mode eth1 and eth2 and etc operate separately Max support 4 network ports You can use the s...

Страница 34: ...ask Gateway display as zero You need to disable DHCP function to view current IP information Besides when PPPoE is operating you can not modify IP Subnet mask Gateway z IP version There are two option...

Страница 35: ...e list supports max 64 IP addresses Figure 3 34 3 5 4 3 NTP Setup You need to install SNTP server Such as Absolute Time Server in your PC first In Windows XP OS you can use command net start w32time t...

Страница 36: ...9 Sydney GMT 10 Hawaii GMT 10 Alaska GMT 9 Pacific Time P T GMT 8 American Mountain Time M T GMT 7 American Central Time C T GMT 6 American Eastern Time E T GMT 5 Atlantic Time GMT 4 Brazil GMT 3 Midd...

Страница 37: ...pace Except the above mentioned addresses of special meaning you can use other addresses For example Multiple cast IP 235 8 8 36 Multiple cast PORT 3666 After you logged in the Web the Web can automat...

Страница 38: ...n Device IP is not fixed if you use ADSL to login the network The DDNS function allows you to access the NVR via the registered domain name Besides the general DDNS the Quick DDNS works with the devic...

Страница 39: ...ion of the device z Status When the UPNP is offline it shows as Searching When the UPNP works it shows Success z Router LAN IP It is the router IP in the LAN z WAN IP It is the router IP in the WAN z...

Страница 40: ...t English character and Arabic number Max 32 digit z Receiver Please input receiver email address here System max supports 3 email boxes z SSL enable System supports SSL encryption box z Interval The...

Страница 41: ...nt activates the email system sends out the email according to the interval you specified here This function is very useful when there are too many emails activated by the abnormity events which may r...

Страница 42: ...p For example the work day ranges from 8 30 17 30 Monday to Friday and then you set the period 7 10 18 00 for Monday So the arm period of the Monday ranges from 7 10 to 18 00 Please highlight the corr...

Страница 43: ...l to alert you when alarm occurs z Record channel you can select proper channel to record alarm video Multiple choices You need to set alarm record mode as Schedule in Record interface Main Menu Advan...

Страница 44: ...38 Figure 3 44 Figure 3 45 Figure 3 46...

Страница 45: ...he motion detection zone Black zone is the disarmed zone You can click Fn button to switch between the arm mode and disarm mode In arm mode you can click the direction buttons to move the green rectan...

Страница 46: ...e is shown as in X305H305H305HFigure 3 50X Click PgUp PgDn to set more channels z Record Delay System can delay the record for specified time after alarm ended The value ranges from 10s to 300s z Tour...

Страница 47: ...41 Figure 3 49 Figure 3 50 Figure 3 51...

Страница 48: ...igure 3 53 Camera Masking When someone viciously masks the lens or the output video is in one color due to the environments light change the system can alert you to guarantee video continuity Camera m...

Страница 49: ...o options 1280 1024 default 1920 1080 Please note the system needs to reboot to activate current setup z Enable tour Activate tour function z Interval System supports 1 4 8 9 16 window tour Input prop...

Страница 50: ...after channel You can see an interface shown as in Figure 3 57 Click PgUp PgDn to view more channels Please note all your modification here applies to local end only You need to refresh web or client...

Страница 51: ...stem pops up a dialogue box You can highlight to restore default factory setup z Select all z General z Encode z Schedule z RS232 z Network z Alarm z Detect z Pan tilt zoom z Display z Channel name Pl...

Страница 52: ...ct one device in the Added device list and then click it to remove z Manual add Click it to add the IPC manually The default port number is 37777 if the manufacture is Private The default user name is...

Страница 53: ...nt alarm output abnormity manual record account auto maintenance configuration backup and RAID management Figure 3 61 3 6 1 HDD Management Here is for you to view and implement hard disk management Se...

Страница 54: ...you can erase all data in the HDD Please note system needs to reboot to get all the modification activated Figure 3 62 Figure 3 63 For the HDD group setup operation please note z Each channel s recor...

Страница 55: ...current hard disk When you are setting the HDD Group please choose the corresponding HDD Group number from the dropdown list and save the settings Figure 3 64 Important HDD group here refers to the HD...

Страница 56: ...ect alarm activation output port multiple choices z Latch Here you can set corresponding delaying time The value ranges from 1s 300s System automatically delays specified seconds in turning off alarm...

Страница 57: ...Right click mouse on the preview mode or in the main menu from Advanced Manual Record you can see manual record menu is shown as in Figure 3 68 You can click the PgUp PgDn button to view more channel...

Страница 58: ...schedule record Please highlight ALL after Schedule See Figure 3 70 When system is in schedule recording all channels will record as you have previously set Main menu Setting Schedule The correspondi...

Страница 59: ...Modify user z Add group z Modify group z Modify password For account management please note z For the user account name and the user group the string max length is 6 byte The backspace in front of or...

Страница 60: ...ew without login z One user should belong to one group User right can not exceed group right z About reusable function this function allows multiple users use the same account to login After all the s...

Страница 61: ...ure 3 75 Figure 3 75 3 6 5 3 Add Modify User Click add user button the interface is shown as in Figure 3 76 Please input the user name password select the group it belongs to from the dropdown list Th...

Страница 62: ...button system goes back to the previous menu Figure 3 77 3 6 7 Config Backup The configuration file backup interface is shown as below See Figure 3 78 This function allows you to copy current system...

Страница 63: ...or you to select See Figure 3 81 z Logout menu user log out menu You need to input password when you login the next time z Restart application reboot device z Shutdown system shuts down and turns off...

Страница 64: ...58 Please note sometimes you need to input the proper password to shut down the device Figure 3 81...

Страница 65: ...not update via port 3777 Then you can use port 3800 to update 2 Click the Login button on the right side system pops up a dialogue box Here you can input user name admin and password admin Click the...

Страница 66: ...oduct max supports 4 network adapters The default setup is eth1 192 168 1 108 eth2 192 168 1 101 eth3 192 168 1 102 and eth4 192 168 1 103 z Use order ping NVR IP address to check connection is OK or...

Страница 67: ...See Figure 5 3 Figure 5 3 Login interface Please input your user name and password Default factory name is admin and password is admin Note For security reasons please modify your password after you...

Страница 68: ...Section 2 System menu z Section 3 PTZ control z Section 4 Video setup and other setup z Section 5 Preview window z Section 6 Monitor window switch 5 2 1 Monitor Channel Menu Tree The monitor channel...

Страница 69: ...1 to channel 128 64 Local play Click local play button to select file to play in PC Refresh Click this button to refresh monitor channel name Please left click one monitor to view real time video the...

Страница 70: ...folder picture download default Please initial version does not support this function Audio Turn on or off audio Close video Close video in current window 5 2 2 System Menu System menu is shown as in...

Страница 71: ...setup button Please note open menu close menu up down left right confirm cancel buttons are for speed dome only z PTZ direction PTZ supports eight directions left right up down upper left upper right...

Страница 72: ...ton to remove one preset from the tour Pattern You can input pattern value and then click start record button to begin PTZ movement Please go back to Figure 7 10 to implement camera operation Then you...

Страница 73: ...erface is shown as in Figure 5 13 Figure 5 13 Color and More Please refer to the following sheet for detailed information Parameter Function Picture Path Click picture path button system pops up an in...

Страница 74: ...are version information Please note the following figure is based on our 128 channel series product and it is for reference only See Figure 5 14 Figure 5 14 Version Information 5 3 1 2 HDD information...

Страница 75: ...nish time Set time to finish search Search You can select log type from the drop down list and then click search button to view the list Clear You can click this button to delete all displayed log fil...

Страница 76: ...r detailed information Parameter Function System Time Here is for you to modify system time Please click Save button after your completed modification Sync PC You can click this button to save the sys...

Страница 77: ...alue ranges from 1 to 120 minute Default setup is 60 minutes Device No When you are using one remote control to manage multiple devices you can give a serial numbers to the device Please note current...

Страница 78: ...tter the image quality Reference bit is an ideal range for you to set bit rate Overlay Cover area z Here you can privacy mask the specified video in the monitor video z One channel max supports 4 priv...

Страница 79: ...73 Figure 5 22 Schedule Time Figure 5 23 Copy Figure 5 24...

Страница 80: ...r complete setup please go back to Figure 5 21 and then click save to save current time period setup Holiday Click Set button system pops up a dialogue box shown as in Figure 5 24 Here you can set hol...

Страница 81: ...ng number to input IP address Then you can set the corresponding subnet mask the default gateway Default Gateway Here you can input the default gateway TCP Port Default value is 37777 You can change i...

Страница 82: ...guration is saved and the device will auto connect to Internet The IP address is the WAN IP z There are two conditions for reboot z 1 The user must have the authority to reboot device z 2 There is no...

Страница 83: ...r IP that can parse the domain SSL enable You can enable SSL encryption function to guarantee data safety Port Default value is 25 You can modify it if necessary User Name The sender email account use...

Страница 84: ...NS and Client end Introduction 1 Background Introduction Device IP is not fixed if you use ADSL to login the network The DDNS function allows you to access the DVR via the registered domain name Besid...

Страница 85: ...ess Important z Do not register frequently The interval between two registrations shall be more than 60 seconds Too many registration requests may result in server attack z System may take back the do...

Страница 86: ...alarm centre server IP port number Once there is an alarm occurred system can notify the alarm centre as you specified here Figure 5 30 Alarm Centre UNPN Go to the UPnP interface you can see an image...

Страница 87: ...81 5 3 2 5 Alarm Alarm setup interface is shown as in Figure 5 32 Figure 5 32 Alarm Setup Figure 5 33 PTZ Setup...

Страница 88: ...alarm can last until the IPC and the NVR connection resumes Alarm in Select corresponding alarm channel Enable You need to draw a circle here so that system can detect the alarm signal Type There are...

Страница 89: ...l to alert you when alarm occurs and ends Screen display After enabled alarm info will be prompted out on the local output end That is to say the alarm prompt will be displayed beside the channel name...

Страница 90: ...ore exit to save the setup Period Here you can set for business day and non business day Anti dither Range 0 600 Alarm output s when alarm occurred system enables peripheral alarm device Record channe...

Страница 91: ...36 Please note system can not restore some information such as network IP address Figure 5 36 Default and Backup Please refer to the following sheet for detailed information Parameter Function Select...

Страница 92: ...as read write Read only Set current HDD as read Redundant Set current HDD as redundant HHD Recover Fix the HDD error Right now the device does not support this function 5 3 3 2 RAID Management This i...

Страница 93: ...tton in Figure 5 38 you can go to the following interface to add or delete hotspare disk See Figure 5 41 Figure 5 39 5 3 3 3 Abnormaliity The interface is shown as in below See Figure 5 40 and Figure...

Страница 94: ...larm output can delay for the specified time after alarm stops The value ranges from 10s to 300s Record channel After you selected the disk connection option once the device is offline the activated c...

Страница 95: ...detailed information Parameter Function Alarm output The value 1 8 here refers to alarm output channels The interface here is for reference only Please click the corresponding number and then click t...

Страница 96: ...auto record function as you set in schedule setup chapter 5 3 2 3 Manual Enable corresponding channel to record no matter what period applied in the record setup Stop Stop current channel record no m...

Страница 97: ...er Please refer to the following sheet for detailed information Parameter Function User Input the user name of the new established account Reusable The reusable account means that this account can be...

Страница 98: ...ely 5 3 3 7 Snapshot Snapshot interface is shown as in Figure 5 46 Figure 5 46 Please refer to the following sheet for detailed information Parameter Function Channel It is the monitor channel Snapsho...

Страница 99: ...nd auto delete old files interval from the dropdown list See Figure 5 47 Figure 5 47 Auto Maintenance 5 3 3 9 Remote device Remote device interface is shown as in Figure 5 48 Figure 5 48 Remote device...

Страница 100: ...gment and the device shall disable the firewall Type Select remote device type here IP address port remote channel Please input remote device IP address port number remote device channel number and ac...

Страница 101: ...nd the blue highlighted date means it has record files Figure 5 50 Search Then please click search button you can see the corresponding files in the list See Figure 5 51 Figure 5 51 Select the file s...

Страница 102: ...p In Figure 5 53 there is a remote back pane at the left bottom of the pane It allows you to backup the record or picture to your local USB storage media via the Web remotely Click the search button y...

Страница 103: ...your reference 5 5 Alarm Click alarm function you can see an interface is shown as in Figure 5 55 Here you can set device alarm type and alarm sound setup When alarm occurs system can display the ala...

Страница 104: ...ice and can activate NVR local operation Alarm Type IPC offline alarm System can generate an alarm when the front end IPC disconnects with the local NVR Listening alarm System notifies web when alarm...

Страница 105: ...99 Figure 5 56 About 5 7 Log out Click log out button you can go back to log in interface See Figure 5 57 Figure 5 57 Alarm...

Страница 106: ...d the toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any b...

Отзывы: