background image

 

21

When you move the cursor to one tour number, please click confirm button to set the tour. Please use 
up/down button to set preset number, dwell time and speed. Use the left/right button to go to the next tour. 
Click confirm button you can exit the setup. After you completed the setup, move the cursor to back button 
to go to the previous interface. 

z

 DELETE 

TOUR

Here is to delete a tour. Input tour number in TOUR NO and then move the cursor to 

DELETE TOUR, click confirm button to delete. 

z

  CALL: Here is to activate tour. Input tour number in tour NO and highlight CALL, click confirm button to 

activate touring.  

z

  STOP: Here is to terminate touring. 

z

  BACK: Go back to previous menu.  

z

  EXIT: Log out system menu. 

 
4.4.4.5

 

Pattern

 

 
 
 
 
 
 
 
 

Pattern function can memory PTZ operation and camera focus zoom in and zoom out.  
From the start position, dome begins auto movement repeatedly. 
Move the cursor to PATTERN and click confirm button. 

z

 PATTERN 

NO

 Here is to set pattern number. Please click left/right key to configure. 

z

  PROGRAM START: Here is to memorize pattern starting point. An icon OK pops up in screen to prompt 

you system begins memory pattern. 

z

 PROGRAM 

STOP

Here is to set pattern stop point.  After all the movement, move the cursor to 

PROGRAM STOP and then click confirm button. Now you have set one pattern. System pops up an 
icon OK to prompt you system has memories one pattern.  

z

 CALL

Here is to activate pattern. Input pattern number, move the cursor to CALL and click confirm 

button, system begins running pattern.  

z

  STOP: Here is to stop current pattern. Input pattern number, move the cursor to STOP and click confirm 

button. System stops current pattern. 

z

  BACK: Go back to previous menu.  

z

  EXIT: Log out system menu. 

Note:

  

z

  The dwell time between two orders should be less than one minute, otherwise system will set to default 

value as one minute. 

z

  After click PROGRAM

 

STOP, do not click CALL button before icon 

●”

 disappears completely.  

z

  Any manual operation during the pattern procedure will terminate current dome pattern operation. 

 

4.4.4.6

 Idle Function

 

 
 
 

PATTERN NO:           

001 

PROGRAM START 

PROGRAM STOP 

CALL  

STOP 

BACK                            EXIT 

Содержание IPPTZ-EL2MPIR250L30X-AT

Страница 1: ...IPPTZ EL2MPIR250L30X AT User s Manual Version 1 0 0...

Страница 2: ...rn 1 1 2 8 3D Privacy Masking 1 1 2 9 Defog 2 1 2 10 3D noise reduction 2 1 2 11 Action on Alarm 2 1 2 12 Auto Flip 2 1 2 13 Self diagnosis 2 1 2 14 Day Night Mode B W Color Mode 2 1 2 15 Auto Focus 2...

Страница 3: ...5 IR Light Setting 26 4 5 Dome Abnormal Phenomenon Operation 26 4 5 1 Restore to Factory Default Setup 26 4 5 2 PTZ Movement is not smooth 26 5 CABLE CONNECTION 27 5 1 Combination Cable Connection 27...

Страница 4: ...eference tool for the operation of your system Here you can find information about this speed dome features and functions as well as a detailed menu tree Please keep it well for future reference Befor...

Страница 5: ...device This series product complies with the IP66 standard specified in the Degrees of Protection Provided by Enclosure z Please make sure the CCD CMOS component is out of the radiation of the laser...

Страница 6: ...use all the accessories recommended by manufacturer Before installation please open the package and check that all the components are included in the package Contact you local retailer ASAP if somethi...

Страница 7: ...The IR high definition speed dome continually decreases or increases pan and tilt speeds in proportion to depth of zoom When zooms speed is increasing the camera moving speed becomes slow When zooms s...

Страница 8: ...iagnosis z Display dome information 1 2 14 Day Night Mode B W Color Mode Auto manual switches in low illumination There are several modes such as photoresistor auto manual and etc This function needs...

Страница 9: ...etc Figure 2 1 Select one IP address and then right click mouse you can see an interface is shown as in Figure 2 2 Note You can set the IP address subnet mask and gateway for the network camera and P...

Страница 10: ...P address and then double click it to open the login interface Or you can select an IP address and then click the Login button to go to the login interface See Figure 2 4 In Figure 2 4 you can view de...

Страница 11: ...uration tool main interface is shown as below See Figure 2 5 Figure 2 5 For detailed information and operation instruction of the quick configuration tool please refer to the Quick Configuration Tool...

Страница 12: ...please set the corresponding gateway and subnet mask z Use order ping speed dome address to check connection is OK or not 3 2 Login and Logout Open IE and input speed dome address in the address bar F...

Страница 13: ...Please input your user name and password Default factory name is admin and password is admin Select the network connection type Note For security reasons please modify your password after you first l...

Страница 14: ...8 Figure 3 4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction...

Страница 15: ...INSIDE TEMP TITILE DISPLAY BACK EXIT DISPLAY SETTING SYSTEM SETTING CAMERA SETTING FUNCTION SETTING EXIT WB SETTING EXPOSURE SETTING DAY NIGHT SETTING FOCUS SETTING IMAGE ADJUST ZOOM SPEED APERTURE AP...

Страница 16: ...ntrol keyboard or the matrix host to control the device please make sure the control parameter of the keyboard or the matrix host is the same with the speed dome OSD including address baud rate parity...

Страница 17: ...SYSTEM INFORMATION and then click confirm button to go to the third submenu z ADDR INFORMATION Move the cursor to SITE INFORMATION and then click confirm button to go to the third submenu z SYSTEM TI...

Страница 18: ...eft right button on the keyboard or in the speed dome terminal menu to set z TIME DISP Display dome system time or not Please use the left right button on the keyboard or in the speed dome terminal me...

Страница 19: ...tem can auto reduce the aperture to lower the video noise when it is in low illumination environment Please use the left right button on the keyboard or in the speed dome terminal menu to set z DEFOG...

Страница 20: ...an lower the cameras auto exposure time to capture the image and enhance the definition Please use the left right button on the keyboard or in the speed dome terminal menu to set z NEXT PAGE It includ...

Страница 21: ...s menu z EXIT Log out system menu 4 4 3 3 3D Noise Reduction Move the cursor to 3D NOISE REUDCTION and then click confirm button you can go to the submenu z CONTROL MODE It is to set 3D noise reductio...

Страница 22: ...en day night mode is Time Move the cursor to DAY TIME item and then click confirm button to go to setup Please user up down button to set the value After completed setup please click confirm button to...

Страница 23: ...Please use the left right button on the keyboard or in the speed dome terminal menu to set z BACK Go back to previous menu z EXIT Log out system menu 4 4 3 8 Defog Move the cursor to DEFOG and then cl...

Страница 24: ...ESTART Move the cursor to current item and then click confirm button to reboot the camera z BACK Go back to previous menu z EXIT Log out system menu 4 4 4 Function Setting Please go back to main menu...

Страница 25: ...e cursor to PRESET NO and then input corresponding preset value Then move the cursor to CALL and then click confirm button to go to a preset z BACK Go back to previous menu z EXIT Log out system menu...

Страница 26: ...an function z STOP Here is to terminate auto scan function z BACK Go back to previous menu z EXIT Log out system menu 4 4 4 4 Tour Move the cursor to highlight TOUR item and then click confirm button...

Страница 27: ...number Please click left right key to configure z PROGRAM START Here is to memorize pattern starting point An icon OK pops up in screen to prompt you system begins memory pattern z PROGRAM STOP Here...

Страница 28: ...ck confirm button to save current setup BACK Go back to previous menu 4 4 4 7 Time Task Schedule task TASK NO Here you can set task number Please use the left right button to set TIME TASK The schedul...

Страница 29: ...u completed the setup please click confirm button to exit end time setup and then move the cursor to the SAVE button to save current setup TASK ACTION The option here includes none tour scan preset pa...

Страница 30: ...irm button system goes to privacy mask setup interface Note z For security reasons please set privacy zone a little bit larger than the privacy object size z Each time after modifications you need to...

Страница 31: ...g operation such as the scan preset pattern tour Please use the left right button to set BACK Go back to the previous menu EXIT Log out the system menu Menu Password Move the cursor to the MENU PASSWO...

Страница 32: ...he IR light sensitivity function z IR LIGHT CTRL There are three options Zoom rate has the higher priority and manual Please use the left right button to set z NEAR LIGHT It is the medium and near lig...

Страница 33: ...port AUDIO IN Audio input port GND Ground port VIDEO OUT Video output port LAN Network port Connect to network cable z Seven alarm input channels It is to receive relay signal from the external alarm...

Страница 34: ...Please refer to Figure 5 1 for system connection information Figure 5 1 5 2 2 Alarm Connection Please refer to Figure 5 2 for alarm connection information Figure 5 2 Network Output AC220V Input Transf...

Страница 35: ...me to power Red LED light on the power board is on z Power supplying is low z Something wrong with power board z Use multimeter to check dome load z Please contact retailer to replace power board Powe...

Страница 36: ...e point to the earth Open floor cable layout is forbidden z In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install addit...

Страница 37: ...ndicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ T11363 2006 standard During the environme...

Страница 38: ...ware here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please re...

Отзывы: