background image

Article numbers / spare parts 

 

Mounting and Installation, Technical Description, T 811 065 en 

39 / 41 

Article numbers / spare parts 

The table below contains only the most important components and spare parts for a SecuriFire 500 fire alarm control panel. 
Article  numbers  for  detectors,  special  detectors,  peripheral  devices,  accessories  etc.  are  found  in  the current product cata-
logue for SecuriFire 500. 
 

7.1 

SecuriFire 500 fire alarm control panels 

Short designation 

Swiss Art. No. 

Art. No. 

B7-SCP520 

SecuriFire 500 (incl. MIC11) 

037.248 150  20-1151000-01-01 

B7-CPB11 

Main control unit 

 

20-1151100-01-01 

B7-MIC11 

The  permanently  built-in  indication  and  control  map  is  not  a 

--

--

DKM SCHL 

Key for SecuriFire 500 map case door 

118.248 193

FG020015 

SI-G 8A 

Replacement fuse for cable set 

--

IS625040 

 

7.2 

SecuriFire addressable loop modules 

Short designation 

Art. No. CH 

Art. No. 

BX-AIM 

Advanced input module 

115.239 763 

EG072947 

GEH MOD IP66 

Map case IP66 for BX-AIM 

403.239 917 

FG020234 

 

M20 step nipple 

-- 

MM000181 

 

M16 mounting screw union 

-- 

MM000185 

 

M16 counter-nut 

-- 

MM000186 

BX-REL4 

Relay module 

115.239 712  20-2100004-01-01 

GEH MOD2 IP66  Map case IP66 for BX-REL4 

403.239 925 

FG020235 

 

M20 step nipple 

-- 

MM000181 

 

M16 mounting screw union 

-- 

MM000185 

 

M16 counter-nut 

-- 

MM000186 

 

Warning sticker for 230 V (10 pcs.), available only in German. 

-- 

3740990 

BX-ESL 

End switch module eXtended Line 

115.239 704  20-2100007-01-01 

BX-IOM 

Input/output module 

115.239 720  20-2100002-01-01 

GEH MOD IP66 

Map case IP66 for BX-IOM 

403.239 917 

FG020234 

 

M20 step nipple 

-- 

MM000181 

 

M16 mounting screw union 

-- 

MM000185 

 

M16 counter-nut 

-- 

MM000186 

BX-IM4 

Input module 

-- 

EG072844 

GEH MOD IP66 

Map case IP66 for BX-IM4 

403.239 917 

FG020234 

 

M20 step nipple 

-- 

MM000181 

 

M16 mounting screw union 

-- 

MM000185 

 

M16 counter-nut 

-- 

MM000186 

BX-I2 

Input module 

--  20-2100016-01-01 

GEH MOD IP66 

Map case IP66 for BX-I2 

403.239 917 

FG020234 

 

M20 step nipple 

-- 

MM000181 

 

M16 mounting screw union 

-- 

MM000185 

 

M16 counter-nut 

-- 

MM000186 

BX-O1 

Output module 

--  20-2100015-01-01 

GEH MOD IP66 

Map case IP66 for BX-O1 

403.239 917 

FG020234 

 

M20 step nipple 

-- 

MM000181 

 

M16 mounting screw union 

-- 

MM000185 

 

M16 counter-nut 

-- 

MM000186 

BX-OI3 

Output/input module 

-- 

-- 

GEH MOD IP66 

IP66 map case for BX-OI3 

403.239 917 

FG020234 

 

M20 step nipple 

-- 

MM000181 

 

M16 mounting screw union 

-- 

MM000185 

 

M16 counter-nut 

-- 

MM000186 

Содержание SecuriFire 500

Страница 1: ...Securiton AG Alpenstrasse 20 3052 Zollikofen Switzerland T 811 065 en SecuriFire 500 Mounting and Installation Technical Description...

Страница 2: ......

Страница 3: ...ot valid This document is protected by copyright Foreign language documentation as listed in this document is always released or changed at the same time as the German edition If there are inconsisten...

Страница 4: ...erted Other safety relevant information Warning The product may be damaged if the safety information is not heeded Description of which damage can occur Measures and preventative actions How dangers c...

Страница 5: ...Document history Mounting and Installation Technical Description T 811 065 en 5 41 Document history First edition Date 24 10 2012...

Страница 6: ......

Страница 7: ...nd control maps X6 21 3 4 1 EPI bus X6 connection 21 3 4 2 Technical data 21 3 5 SecuriLine eXtended 22 3 5 1 SecuriLine eXtended x12 connection 22 3 5 2 Technical data 22 3 5 3 Compatibility informat...

Страница 8: ...ays fault patterns 38 6 5 Simple troubleshooting 38 6 5 1 General 38 6 5 2 Contaminated detector 38 6 5 3 Possible causes of faults 38 _________________________________________________________________...

Страница 9: ...0 m Up to 3 indication and control maps e g fire brigade maps can be connected via EPI bus 3 relay outputs Alphanumeric display 320 x 240 pixels in plain text in German or in the language of the count...

Страница 10: ...The earthing concept used in the SecuriFire 500 with central protection earthing to protect persons and electronics requires that all electrically charged components connected to the GND line of the S...

Страница 11: ...nd control maps including fire brigade panels max 3 EPI devices with max 1 metre line length Detection zones inputs outputs max 756 dynamically divided External e g sprinkler systems max 256 Delay lay...

Страница 12: ...ces max 1 m 24 V 2 5 A power supply unit integrated 2 pcs 12 V 7 2 Ah emergency power batter ies in series Mains terminals and battery cable Integrated indication and control map B7 MIC11 2 3 4 5 6 1a...

Страница 13: ...e applicable 2 2 Drilling plan All dimensions in mm Fig 5 SecuriFire 500 drilling plan Mount rear wall according to drill plan with 4 pcs 5 x 40 round head screws and 4 pcs S 8 dowels When mounting on...

Страница 14: ...ection 230 V 110 V X2 Control panel interface to the B7 MIC11 X5 Interface of the relay contacts X6 Interface for EPI bus extended bus X10 Interface for monitored inputs and outputs X11 Output voltage...

Страница 15: ...battery and without external voltage When manipulating the individual units it is imperative that you observe the regulations regarding precautions against static charges ESD protective measures 3 2 1...

Страница 16: ...rovide the power for the control unit The batteries are mounted below in SecuriFire 500 map case Notice Only the following VdS tested and Securiton approved battery types can be used if others are use...

Страница 17: ...normally closed contact By programming an Active in fail safe position the state of each individual relay can be defined for power supply failure or shut down of the control panel X5 connector plug P...

Страница 18: ...ig 8 B7 CPB11 relay output connection of 230 V consumers 1 6 X5 B7 CPB11 X11 1 2 Siren Working contact Fig 9 B7 CPB11 relay output siren connection When connecting inductive loads it is recommended to...

Страница 19: ...max 0 5 A TUS max 0 1 A OM modes of operation Monitored output with area 1 and 2 or TUS TUS only for OM1 Planning with software see table for values Feedback input Feedback from MDLF Input current 3...

Страница 20: ...ds Fig 12 B7 CPB11 electronic loads Connection with feedback _ Transmission unit 1 B7 CPB11 X10 9 Notice Because of the number of different transmis sion unit systems their description is not in clude...

Страница 21: ...unit Fire brigade control panel Switzerland B5 EPI FPC Fire brigade control panel Germany B5 EPI FPD Fire brigade indicator board B5 EPI FAT Fire brigade control panel Czech Republic B5 EPI FPCZ Fire...

Страница 22: ...ent max 232 mA Loop interface 6 pin screw terminal Loop and stub line lengths max 3 500 m Notice The properties of the SecuriLine eXtended e g 250 participants per loop apply only when SecuriLine eXte...

Страница 23: ...d For purposes of clarity however we recommend continuing with one wir ing system once begun 4 3 2 1 5 7 6 8 MCP 535X 1 2 3 4 5 6 MCP 545 GND SHLD SHLD GND L1 L2 1 3 4 5 6 2 6 5 4 3 2 1 USB 501 L2 L1...

Страница 24: ...45X MCP 545N SHLD GND L1 GND SHLD L2 1 2 3 4 5 6 7 8 MCP 545X MCP 545N 1 2 3 4 5 6 MCP 545 GND SHLD SHLD GND L1 L2 Fig 16 Stub line connection 3 6 2 Connecting detector base USB 501 The MCD 573X MCD 5...

Страница 25: ...ng other things it can be used to connect intrinsically safe detectors Ex i with inter mediate switching of a Zener barrier An output for a repeat signal is also available More information about the B...

Страница 26: ...put further each input can be programmed inverted More information about the BX IM4 can be found in the data sheet T 131 462 Monitored inputs GND SHLD SHLD GND L1 L2 X2 IN4 IN3 IN2 IN1 IN4 IN3 IN2 IN1...

Страница 27: ...programmed inverted More information about the BX I2 can be found in the data sheet T 811 069 Input monitored or unmonitored GND SHLD SHLD GND L 1 L2 X2 IN2 IN3 Inp ut 3 IN2 IN3 IN1 IN1 1 1 X1 In put...

Страница 28: ...sources The input can be used to poll potential bound voltage sources The monitored output is divided into three load ranges and can actuate and monitor a load between 20 and 1 k Further information...

Страница 29: ...LD SHLD GND L1 L2 X2 X3 IN2 IN3 Input 2 Input 3 IN2 IN3 IN1 IN1 1 COM NC NO Relay 1 1 X1 Input 1 Vext L1 L2 GND GND SHLD SHLD 180 180 Scan external voltages Actuation of fire incident controls Scan po...

Страница 30: ...actuation as standby contact e g control electronics Example 2 actuation with external voltage supply e g ventilation motor M External power supply Input 4 unmonitored Elevator control max 30m Fig 30...

Страница 31: ...REL4 1 NC1 NC2 NC3 NC4 NO1 NO2 NO3 NO4 COM1 COM2 COM3 COM4 X1 X2 X3 X4 Example 1 actuation with own voltage supply e g sirens Example 2 actuation as standby contact e g control electronics Example 3...

Страница 32: ...VOL FLASH Fig 34 BX SOL loop siren connection Notice The settings of the DIP switches are not relevant in the SecuriLine eXtended mode 3 6 14 Loop flashlight BX FOL connection Further information abo...

Страница 33: ...by means of a LED Further information about the BX ESL can be found in the data sheet T 131 460 The BX ESL is built into a plastic switch housing The ca bles are conveyed through the PG screw junction...

Страница 34: ...standards All necessary software and system components are available as a SecuriFire software package which contains planning commissioning maintenance and diagnostics for control units of the SecuriF...

Страница 35: ...of a power failure the fire alarm control panel is powered by batteries Depending on the con nected peripheral devices EPI devices detectors sirens etc it is important to ensure that the batteries hav...

Страница 36: ...ion interrupt the battery cable at an appropriate point and loop the measuring instrument multimeter voltmeter in the battery cable There must be no pending alarms or disablements the batteries must b...

Страница 37: ...erred to the control panel A wizard developed specifically for SecuriFire 500 is available which provides guidance for fast commissioning in 8 steps The EasyConfig SecuriFire 500 wizard is integrated...

Страница 38: ...played by the Call service pictogram and in a contamination list on the indication and control map of the SecuriFire The following procedure is recommended for contaminated detectors Press the Lists b...

Страница 39: ...00186 BX REL4 Relay module 115 239 712 20 2100004 01 01 GEH MOD2 IP66 Map case IP66 for BX REL4 403 239 925 FG020235 M20 step nipple MM000181 M16 mounting screw union MM000185 M16 counter nut MM000186...

Страница 40: ...oop siren red map case 239798 20 2100008 01 02 BX SOL W Loop siren white map case 239780 20 2100008 02 02 EHB 701 Empty housing with blind cover 12 4400038 01 01 7 3 SecuriFire EPI devices Short desig...

Страница 41: ...Fig 16 Stub line connection 24 Fig 17 USB 501 connection 24 Fig 18 RAL720X connection 24 Fig 19 MCP 535x connection 25 Fig 20 MCP 545x connection 25 Fig 21 BX AIM collective detector and monitored in...

Отзывы: