16.3 Simple Mechanical Reset
SecuRam Safe Locks can operate in either Analog mode or Digital mode. When they
are paired with the SafeLogic Series (EntryPads with no LCD screen or fingerprint reader)
the safe lock operates in analog mode.
When paired with a ProLogic Series (EntryPads with an LCD screen) or ScanLogic
(EntryPads with a fingerprint reader and/or LCD screen), the safe lock operates in digital
mode.
The ProLogic L02 is a digital system and can be paired with any SecuRam safe lock body.
If the lock body that you are pairing the ProLogic L02 with has been paired previously
with an analog system, for example the SafeLogic Basic (or any other SafeLogic Series
EntryPad) or was set at the factory in the default Analog mode, the following Simple
Mechanical Reset procedure must be followed.
Step 1: Ensure that the EntryPad is not connected to the lock, and that the
battery is not connected to the EntryPad.
Step 2: Find the reset hole on the back of the lock (under the QC sticker).