Now all users are deleted successfully.  

14. Dual Mode 

Unlock using a Manager

. When the LCD shows “Select Menu”, press “▲” or “▼” to select 

“Enable Dual Mode”. Press “Menu/OK” and then enter another enrolled code. When the 

LCD shows: 

               

 

Dual Mode function is activated.   

Note:   

 Managers

’ codes (ID No. 01 & 02) are Dual Mode Overide Codes.     

 In order to open the lock in Dual Mode, the second code must be entered within 60 

seconds after the first code is successfully verified.

 

 

 If all users are deleted, Dual Mode will be disabled automatically.   

 In Dual Mode, Managers cannot be deleted.   

 When changing a code in Dual Mode, only the second entered code can be changed.   

  

15. System Info. 

Press 

“Menu/OK”. Press “▲” or “▼”to select “System Info.”. Press “Menu/OK” and the 

LCD will show data about the safe lock system including 

 

EntryPad Part Number EC-0601A-L02 

 

Firmware version number, i.e. V 1.63100929 

 

Total User capacity and number of Users currently enrolled, i.e. Users: 30/01used 

 

16.0    Recovering the System 

– Reset to Default 

The  ProLogic  Series  safe  lock  systems  have  the  ability  to  be  reset  to  factory  default 

settings using a very unique secure method.      Each system has a default recovery code.   

The  Default  code  is  999999  -  this  code  can  be  changed  as  necessary,  refer  to  the 

Recovery Code Set selection. 

 

Upon entry of the recovery code, the LCD screen displays an alpha-numeric code.    This 

code cannot be used to open the safe lock system or to change the code to factory default.   
The  alpha  numeric  code  must  be  deciphered  using  a  SecuRam’s  Authorization  Code 
Generator Software. 

 

The alpha-numeric  code  is  entered into  the  software  together  with  the  encryption  code.   

Through  the  software,  these  codes  are  deciphered  to  generate  a  One  Time  Use  Reset 

Code. 

 

Содержание ProLogic L02

Страница 1: ...battery Take the battery out of the battery compartment 2 Gently remove the connector by unsnapping it from the two terminals on the top of the battery Never Pull on the Battery Leads 3 Connect a new...

Страница 2: ...enter When a code is entered the display will show the last digit entered 2 Enroll ID02 Code ID02 is also a Manager Code Enter Manager code ID No 01 When the LCD screen shows Select Menu press or and...

Страница 3: ...ter the same code again 6 digits 5 Disable user This function allows a Manager to temporarily disable a USER code without deleting it permanently This may be used while an employee is on vacation and...

Страница 4: ...first Penalty time period without a correct code entry two more consecutive invalid code entries will restart an additional 4 minutes delay period An attempt to unlock using a valid code will not ter...

Страница 5: ...e first ID in the group to be authorized For example ID 03 Press Menu OK Press or to set the last ID in the group of Users to be authorized For example to authorize users with ID No from 03 to 05 scro...

Страница 6: ...ows Select Menu Press or and select Set Cancel Time Delay Press Menu OK Press or to set time delay 1 to 99 min Press Menu OK Press or to select Time Window 0 to 15 min Press Menu OK Now the time delay...

Страница 7: ...me delay When changing Time Delay if the period is longer than the previous one the new time delay will be effective during the next unlocking 11 Unlocking with an enrolled code with Time Delay and Mu...

Страница 8: ...lay Override can unlock the lock body without delay IMPORTANT If the Time Window is set to 0 minutes there is no need to enter a code after Time Delay has expired When Time Delay ends the lock body wi...

Страница 9: ...about the safe lock system including EntryPad Part Number EC 0601A L02 Firmware version number i e V 1 63100929 Total User capacity and number of Users currently enrolled i e Users 30 01used 16 0 Rec...

Страница 10: ...999999 It is not necessary to change this code but if preferred this code can be changed with the following procedure Step1 Press the Menu OK button Step 2 Using the and scroll to the System Menu and...

Страница 11: ...ry Code has now been set DO NOT lose this code Without this code your system cannot be recovered in the future 16 2 Recover System In the event that you need to recover the system during its use the f...

Страница 12: ...and call an authorized SecuRam Recovery Center or SecuRam Tech Support at 1 805 988 8088 Step 5 After receiving the One Time Use Recovery Code from the Recovery Center press the back button and you wi...

Страница 13: ...e lock operates in digital mode The ProLogic L02 is a digital system and can be paired with any SecuRam safe lock body If the lock body that you are pairing the ProLogic L02 with has been paired previ...

Страница 14: ...nt to the Lock body telling it to convert from analog to digital mode The ProLogic will now be able to operate the lock body Q How do you know if the lock has been reset The ProLogic will not sound or...

Отзывы: