ScanLogic B22
Operation Instructions
24
Step 7: After receiving the One Time Use Authorization Code from the Recovery Center, press
the “back” button; and you will be prompted to enter your Authorization Code.
Step 8: To continue with the reset, press Menu/OK
Step 9: System will be restored
The Super Code will now be reset to 111111.
The Manager Code will now be reset to 123456.
9.3 Mechanical Reset
SECURAM Safe Locks can operate in either Analog mode or Digital mode. When they are paired with the
SafeLogic Series (EntryPads with no LCD screen or fingerprint scanner) the safe lock operates in analog
mode.
When paired with a ProLogic Series (EntryPads with an LCD screen) or ScanLogic (EntryPads with a
fingerprint scanner and/or LCD screen), the safe lock operates in digital mode.
The ScanLogic B22 is a digital system and can be paired with any SECURAM safe lock body.
Note: The pairing of the StrikeBolt and the ScanLogic B22 EntryPad is not UL listed.
If the lock body that you are pairing the ScanLogic B22 with has been paired previously with an analog
system, for example the SafeLogic Basic (or any other SafeLogic Series EntryPad)or was set at the factory
in the default Analog mode, the following Mechanical Reset procedure must be followed:
Step 1: Ensure that the EntryPad is not connected to the lock, and that the battery is connected
to the EntryPad.
Step 2: Find the reset hole on the back of the lock (under the QC sticker).
Step 3: Using a poke tool, depress the reset button on the back of the lock 3 times. This
discharges any latent energy within the lock’s capacitors.