18
RS-232 Standard Interface port
The RS-232 interface uses a 9-pin female D-sub connector. This information consists of data about utility, load and the UPS.
The interface port pins and their functions are identified in the following table.
Pin #
Signal name
Direction (re UPS)
Functions
2
TxD
Output
TxD Output
3
RxD
Input
RxD / Inverter Off Input
5
Common
Common
6
CTS
Output
Ac Fail Output
8
DCD
Output
Low Battery Output
9
RI
Output
+8-24 VDC Power
USB port
Connecting the UPS to your computer is accomplished through the USB port on the back of your
computer. USB compliant hardware and operating system will be necessary including installation of a
UPS driver. The serial port cannot be used when using the USB port. The USB cable is standard and can
be bought separately.
EPO port
(emergency power off)
A customer-supplied switch located remotely can be used to open the EPO connection and allows UPS
output receptacles to be switched off. Since the EPO shuts down the equipment immediately, orderly
shutdown procedures are not followed and not by any power management software. The UPS will have to
be manually restarted in order to regain power to the outlets.
Network Transient protector
The network transient protector, located on the back panel, has both IN and OUT jacks, and houses a
single RJ-45 (10BaseT) network connector. Connect the input connector to the jack labeled IN, and the
output connector to the jack labeled OUT.
Load segments
The power management software controls the sets of receptacles known as load segments which provides
organized shutdown and startup of the equipment. Less critical equipment can be turned off during power
outages saving battery power for critical loads. The power management software manual has more details
regarding this. The load group status can be viewed from the LCD display and can be changed if
necessary. These load segments are usually handled with the UPS management software. Refer to chapter
5.2 regarding the two load segments that come with each model.
Caution! Max rated values
24Vdc/50mA
Содержание ROLINE ProSecure II 1000 VA
Страница 1: ...I ROLINE ProSecure II 700 1000 1500 2000 3000VA Standger t 19 Rack 1HE 2HE Bedienungsanleitung...
Страница 13: ...7 Installation der Rack Mount Typen Installation mit unteren Schienen Installation mit hinterem B gel...
Страница 14: ...8 R ckseitenansichten...
Страница 15: ...9...
Страница 30: ...ProSecure II 700 VA 3000 VA UPS User s and Installation Manual...
Страница 43: ...13 Installation of Rack mounted types Installation with bottom bracket Installation with rear bracket...
Страница 44: ...14 Rear panel views PROSECURE II 700 1 5KVA REAR PANEL PROSECURE II 2 3KVA REAR PANEL...