Programing Door Propped-Open / Forced-Open Detection:
The device can be programmed to indicate when the door is left open too long (propped-open) or
when there is a forced entry. The door propped-open detection only triggers the internal
sounds/notifications, while the door forced-open detection triggers both. If this setting is enabled:
•
If the door is open for more than one minute, the keypad will begin beeping to remind a user to
close the door. The beeping can be stopped by either closing the door or entering a valid
master code, user code, or fingerprint.
•
If the door is opened by force, both the internal notification beep and an external alarm will
sound and continue to sound until disabled by entering a valid master code, user code, or
fingerprint.
•
This feature requires the notifications and/or alarm output to be enabled (see "Programming
the Keypad Sounds/Notifications," pgs. 18~19 and "Programming the External Alarm Output,"
pg. 19), an external alarm connection, as well as connection to a door sensor magnetic contact
or a lock with a built-in door sensor.
When programming the door propped-open / forced-open detection, use the following general
formula from within base programming mode (see "Enter and Exit Base Programming Mode,"
pg. 9):
– Program the Door Propped-Open / Forced-Open Detection function code (LED will
change to steady orange)
–Disable or Enable the Door Propped-Open / Forced-Open Detection
Disable or Enable Door Propped-Open / Forced-Open Detection:
•
– Disable the door propped-open / forced-open detection (factory default)
•
– Enable the door propped-open / forced-open detection
NOTES:
•
The
key returns you to base programming mode (the LED will flash red). To program other
functions, press the function code for that function (LED becomes steady orange).
•
Exit programming mode by pressing the
key after all programming is completed. One beep
will sound and the LED will return to steady red. After 25 seconds of inactivity, the keypad will
automatically exit programming mode and return to standby.
Examples:
1.
Disable the door propped-open / forced-open detection:
2.
Enable the
door propped-open / forced-open detection: