![SECO-LARM SLI ENFORCER SK-2612-SFSQ Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/seco-larm/sli-enforcer-sk-2612-sfsq/sli-enforcer-sk-2612-sfsq_manual_1230755019.webp)
ENFORCER Fingerprint Reader and Keypad
SECO-LARM U.S.A., Inc.
19
Programming the Keypad Sounds/Notifications (Continued):
Programming the External Alarm Output:
The external alarm output sends certain notifications to an external alarm. These include the
tamper, wrong-code alarm (if enabled, see "Programming the Wrong-Code Lockout/Alarm,"
pg. 21), and the door-forced-open alarm (if enabled, see "Programming the Door Propped-Open /
Forced-Open Detection," pg. 20). When programming the alarm, use the following general formula
from within base programming mode
(see "Enter and Exit Base Programming Mode," pg. 9):
– Program Alarm function code (LED will change to steady orange)
– Alarm Disable/Enable and Alarm Time
Alarm Disable/Enable and Alarm Time:
•
– Disable alarm
•
to
– Enable and set the alarm time, 1~3 minutes (factory default, 1 minute)
NOTES:
•
The
key returns you to base programming mode (the LED will flash red). To program other
functions, press the function code for that function (LED becomes steady orange).
•
Exit programming mode by pressing the
key after all programming is completed. One beep
will sound and the LED will return to steady red. After 25 seconds of inactivity, the keypad will
automatically exit programming mode and return to standby.
Examples:
1.
Disable the alarm:
2.
Enable the alarm and set it to 2 minutes:
NOTES:
•
Disabling the keypad sounds/notifications only affects the internal notifications. The external
alarm is programmed separately.
•
Some notifications will trigger both the internal notification beep and the external alarm, but
some will trigger only one or the other.
•
The
key returns you to base programming mode (the LED will flash red). To program other
functions, press the function code for that function (LED becomes steady orange).
•
Exit programming mode by pressing the
key after all programming is completed. One beep
will sound and the LED will return to steady red. After 25 seconds of inactivity, the keypad will
automatically exit programming mode and return to standby.