SECO-LARM SLI ENFORCER SK-2612-SFSQ Скачать руководство пользователя страница 10

ENFORCER Fingerprint Reader and Keypad 

10

 

SECO-LARM U.S.A., Inc. 

Programming the Master Add/Delete Fingerprints (Continued):  

Programming the Master Programming Code:  

In this manual, the format used for programming the keypad is as follows: 

 

A single-digit

 

(

) FUNCTION CODE to tell the keypad what is being programmed. 

 

A varying number of digits (

) to represent the parameters of that FUNCTION. 

 

The 

 key to confirm programming of the FUNCTION and exit to base programming mode. 

 

The 

 key to exit programming mode and return to standby mode.  

The following is a list of the different programming functions: 

Function 

Code* 

Parameters 

Default Functions and Values 

Page # 

Master programing code 

Default 123456, code length 6 digits 

10 

Add user codes/fingerprints 

No default, must be programmed 

11~14 

Delete user codes/fingerprints 

No default, must be programmed 

15~16 

Output mode/time 

Momentary 5 seconds 

16~17 

Access mode / security level 

Either user code or fingerprints 

17~18 

Wrong-code lockout / external alarm 

Lockout disabled, alarm enabled 1 minute 

19, 21 

Keypad sounds / interlock system / door 
propped-open/forced-open notification 

Sounds enabled, interlock disabled, door 
open notification disabled 

18~20, 

24~25 

Set device ID for Wiegand controller 

22~23 

Set Wiegand output bits/format 

Output bits 26, output bits 4 

23~24 

*Press the function code only to enter the programming mode for that function. It should not be 
repeated between each parameter. 

Programming Format and Default Values:  

 

 

The master programming code is used to enter programming mode. The master programming 
code does not serve as a user code to activate the keypad output. 

1.

 

Make sure the keypad is in base programming mode (see "Enter and Exit Base Programming 

Mode

,

" pg. 9).

 

2.

 

Enter the new master programming code (6 digits):  

 

(where "X" is the new master programming 

code) 

3.

 

Exit programming mode:  
Press the 

 

key or wait 25 seconds to exit automatically. 

NOTE:

 Programming the master add/delete fingerprints also resets the keypad to factory default. 

Though all user information is retained, the master code will return to the default 123456, 
and other settings will return to the default. Because of this, if you desire to use the master 
add/delete fingerprints, it is best to program them before programming any other settings. 

Содержание SLI ENFORCER SK-2612-SFSQ

Страница 1: ...rs User code length 4 6 digits Fingerprint identification time 1 second Fingerprint false acceptance rate 0 01 Fingerprint false rejection rate 0 1 12VDC Operation Form C relay output 2A 12VDC Tamper...

Страница 2: ...prevent operation of the strike from damaging the fingerprint reader keypad Do not connect a diode when using electromagnetic locks or with AC powered strikes Quick Installation Guide Orange Output N...

Страница 3: ...is the factory default master programming code A new master programming code 6 digits should be set the first time you enter programming mode There is no master programming fingerprint 2 Set the mast...

Страница 4: ...ing Access Mode Security Level 17 18 Programming Keypad Sounds Notifications 18 19 Programming the External Alarm Output 19 Programming Door Propped Open Forced Open Detection 20 Programming the Wrong...

Страница 5: ...ompleted 2 The fingerprint reader keypad must be properly grounded Use a minimum 22AWG wire connected to the common ground wire Failure to do so may damage the unit 3 All wiring and programming should...

Страница 6: ...unting screws and mounting screw anchors if necessary Ensure the correct orientation as shown in Fig 2 8 Connect the wires to the fingerprint reader keypad according to Wiring Chart below 9 Finish ass...

Страница 7: ...mming mode The initial master programming code is disabled after setting the new master programming code The master programming code is 6 digits in length and there can be only one master programming...

Страница 8: ...Programming the Access Mode Security Level pgs 17 18 User code only A user must use a user code for access see Programming User Codes pg 14 Fingerprint only A user must use a fingerprint for access se...

Страница 9: ...elete Fingerprints Enter and Exit Base Programming Mode All programming of the fingerprint reader keypad is done from base programming mode 1 Enter base programming mode using the master programming c...

Страница 10: ...e 19 21 6 Keypad sounds interlock system door propped open forced open notification Sounds enabled interlock disabled door open notification disabled 18 20 24 25 7 Set device ID for Wiegand controller...

Страница 11: ...without repeating the function code Exit programming mode by pressing the key after all programming is completed One beep will sound and the LED will return to steady red After 25 seconds of inactivi...

Страница 12: ...tomatically assign the user fingerprint to the first available user ID Each user ID must be unique and cannot be repeated for multiple user fingerprints or codes represents the user fingerprint which...

Страница 13: ...e assigned to the first available fingerprint user ID in numerical order IDs 1 998 Master Add fingerprint The device will beep once the green LED will flash once then change to steady orange User s fi...

Страница 14: ...ngerprints or codes Additional users may be entered in succession without repeating the function code To return to base programming mode to program other functions press the key the LED will flash red...

Страница 15: ...he master add fingerprint 1st user wait for beep then 2nd user NOTE The master delete fingerprint can only be used to delete fingerprint users not user codes Deleting User Fingerprints When User Is Pr...

Страница 16: ...d return to standby Examples 1 Delete a user fingerprint for an available fingerprint present the user fingerprint to be deleted 2 Delete a user fingerprint for an unavailable fingerprint assigned to...

Страница 17: ...toggle mode 2 Set the output to 60 seconds The fingerprint reader keypad can be programmed to one of four access modes security levels User code only a user must use a user code for access Fingerprin...

Страница 18: ...y orange Exit programming mode by pressing the key after all programming is completed One beep will sound and the LED will return to steady red After 25 seconds of inactivity the keypad will automatic...

Страница 19: ...program other functions press the function code for that function LED becomes steady orange Exit programming mode by pressing the key after all programming is completed One beep will sound and the LE...

Страница 20: ...Output pg 19 an external alarm connection as well as connection to a door sensor magnetic contact or a lock with a built in door sensor When programming the door propped open forced open detection us...

Страница 21: ...to deny access for 10 minutes Enable wrong code alarm to sound the keypad notifications external alarm NOTES If wrong code lockout is enabled the LED will flash red and all access will be denied for...

Страница 22: ...card number on the controller the fingerprints will be successfully added Programming the Wiegand Output Bits Format When programming the Wiegand output format use the following general formula from w...

Страница 23: ...gramming Mode pg 9 Programming the Device ID function code LED will change to steady orange Device ID number 0 255 default 0 NOTES The key returns you to base programming mode the LED will flash red T...

Страница 24: ...when the device ID is 255 User code 5555 4 digits device output is 255 05555 User code 55555 5 digits device output is 000 55555 User code 555555 6 digits device output is 005 55555 Door 1 electric L...

Страница 25: ...eader Keypad to Factory Default Setting Up an Interlock System with Two Keypads Continued Programming the Interlock System When programming the interlock system use the following general formula from...

Страница 26: ...S A Inc Installer Notes Factory Default Master Programming Code must change 123456 New Master Programming Code 6 digits User s Name User ID User Code 4 6 digits Fingerprint NOTE Copy this page to kee...

Страница 27: ...followed by the key and or fingerprints They can be input in any order but with no more than a 5 second interval each code fingerprint If not complete within 5 seconds the device will return to stand...

Страница 28: ...or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmans...

Отзывы: