ENFORCER Stand-Alone / Wiegand Proximity Reader
12
SECO-LARM U.S.A., Inc.
Programming the External Alarm Output (Continued):
Programming the Wrong-Card Lockout/Alarm:
The device can be programmed to either lockout or sound an internal alarm after 10 successive wrong cards.
The lockout continues and the LED flashes red for 10 minutes and cannot be reset before then. The built-in
notifications and external alarm sounds for the length of time set in the alarm settings (1~3 minutes, see notes
below), or until stopped with a valid user card or the master programming code using the infrared remote.
When programming the wrong-card lockout, use the following general formula from within base programming
mode (see "Enter and Exit Base Programming Mode," pg. 6):
– Program Wrong-Card Lockout/Alarm function code (LED will change to steady orange)
–Disable or Enable/Configure the Wrong-Card Lockout/Alarm
Disable or Enable/Configure Wrong-Card Lockout/Alarm:
– Disable wrong-card lockout (factory default)
– Enable wrong-card lockout to deny access for 10 minutes
– Enable wrong-card alarm to sound the keypad notifications / external alarm
NOTES:
If wrong-card lockout is enabled, the LED will flash red and all access will be denied for 10 minutes after
10 successive wrong cards.
If wrong-card alarm is enabled, the LED will flash red and the built-in notifications (if enabled, see
"Programming the Notification Sounds and LED," pg. 11) and external alarm (if enabled, see
"Programming the External Alarm Output, pgs. 11~12) will sound and continue for the length of time
programmed for the alarm or until a valid master programming code or user card is entered. This setting
requires either or both the built-in notifications and external alarm output to be enabled and the alarm
timing is set by the external alarm settings.
– Program Alarm function code (LED will change to steady orange)
– Alarm Disable/Enable and Alarm Time
Alarm Disable/Enable and Alarm Time:
– Disable alarm (factory default)
to – Enable and set the alarm time, 1~3 minutes (factory default, 1 minute)
NOTES:
When in Wiegand reader mode, the external alarm programming will have no effect. External alarms are
handled by the controller. The reader will have no tamper alarm.
The key returns you to base programming mode (the LED will flash red). Exit programming mode by
pressing the key (see "Enter and Exit Base Programming Mode," pg. 6).
Examples:
1.
Disable the external alarm:
2.
Enable the external alarm and set it to 2 minutes: