ENFORCER Stand-Alone / Wiegand Proximity Reader
SECO-LARM U.S.A., Inc.
13
Programming the Wrong-Card Lockout/Alarm (Continued):
Setting up a Two-Door Interlock System with Two Readers:
User Operation of the Reader:
Present the proximity card to activate the relay.
You should hear 1 beep (if sounds are enabled) and the status LED should turn green to indicate that the
user card is accepted and the door is unlocked.
Present the proximity card to silence an alarm (except for duress alarms).
The key returns you to base programming mode (the LED will flash red). Exit programming mode by
pressing the key (see "Enter and Exit Base Programming Mode," pg. 6).
Examples:
1.
Disable the wrong-card lockout:
2.
Enable the wrong-card lockout to deny access for 10 minutes:
3.
Enable the wrong-card alarm for the set time (disabled with a valid master code or user card):
Door 1
electric
Lock
Egress
Button
Door 1
Sensor
(+)
(–)
Alarm
Red (+)
Purple (COM)
Gray (GND)
Black (–)
Yellow (N.O.)
Brown
Blue (N.O.)
Orange (N.C.)
or
Door 2
Sensor
Egress
Button
Alarm
Cathode
Output Relay
N.O. Output for
Fail-secure Lock
N.C. Output for
Fail-safe Lock
Red(+)
Purple (COM)
Gray (GND)
Black (–)
Yellow (N.O.)
Brown
Blue (N.O.)
Orange (N.C.)
Cathode
Green – Data 0
White – Data 1
Green – Data 0
White – Data 1
(–)
(–)
(+)
(+)
(–)
(–)
(+)
(+)
or
Door 2
Door 1
Wiegand
Controller
Wiegand
Controller
12VDC
Power Supply
Door 2
electric
Lock
Diode IN4007
(see note
below)
Output Relay
N.O. Output for
Fail-secure Lock
N.C. Output for
Fail-safe Lock
NOTE:
For DC-powered electric strikes, connect the included diode as close as possible and in parallel with the electric
strike. This absorbs possible electromagnetic interference to prevent operation of the strike from damaging the
reader. Do not connect a diode when using electromagnetic locks or with AC powered strikes.
In this application, two readers are each connected to separate door locks and egress pushbuttons. While
one door is open, the other cannot be opened.
Two-Door Interlock Wiring Diagram:
Programming the Interlock System:
When programming the interlock system, use the following general formula from within base programming
mode (see "Enter and Exit Base Programming Mode," pg. 6):
– Program the Interlock System function code (LED will change to steady orange)
– Disable or Enable the Interlock System