1.4 Technical parameters
Working Voltage: AC/DC10-28V
Standby current: ≤35mA(Input DC12V)
Operating current: ≤100mA(Input DC12V)
Working temperature: -40
~
60
℃
Working humidity: 0
~
95%
Lock signal relay contact current: ≤1A
Alarm (or doorbell) signal MOS tube output current: ≤1A
Distance of reading EM card:≤5cm
Distance of reading HID card:≤5cm
Distance of reading IC card:≤5cm
1.5 Applicable models
This user manual applies to the following models:
Thumbnails
Product name
Product model
Card type
Keypad
Lead wire
Single-door Standalone Access
Controller
B6-EH Plus
EM/HID
Infrared
12
B6-IC Plus
IC/CPU
Infrared
12
Single-door Standalone Access
Controller
B6K-EH Plus
EM/HID
Own
12
B6K-IC Plus
IC/CPU
Own
12
Double-doors Standalone Access
Controller
B6K2-EH Plus
EM/HID
Own
16
B6K2-IC Plus
IC/CPU
Own
16
2 Installation, wiring and debugging
2.1 Installation
With the special anti-demolition screw-driver remove the anti-demolition screw at the bottom of the device. Take off the
bottom case, and contrast the opening position of the bottom case and use the impact drilling to open the corresponding
hole on the wall. It includes an outlet hole with a diameter greater than 8mm and four plastic screw holes with a diameter of
6mm. Then insert four matching plastic expansion screws, fix the bottom case on the wall with four matching self-tapping