BEEP: Buzzer control wire, Buzzer keep sounds when low level.
When LED_G & LED_R turns to low level together, the LED indicator light will turn to orange(LED indicator light mode is
0),Green(LED indicator light mode is 1) or red ( LED indicator light mode is 2) .
4.5.2 Operation characteristics in Single-door mode
The default mode is Single-door mode, most applications work in this mode, in this mode, cannot operate the menu 60-64,
also cannot enter the second operation zone.
4.5.3 Operation characteristics in Double-doors mode
Double-doors mode means one machine can control two doors. It will choose different door according to the user card
number or the PIN digits. Double-doors mode not only support all the functions of Single-door mode but also support
separate setting of the second door. After add 2 in front of the 6-digit Admin Password, it turns a 7-digit Admin Password,
you can enter the zone 2 to set. The admin card setting is the same with the zone 1. With 7-digit Admin Password into
management mode, only menus 00, 01, 02, 10-12, 21, 22, 30-36 are valid.
4.5.4 Operation characteristics in Interlock mode
Interlock mode is refers to interlocking between two door, installing a machine and a Magnetic Door Contact on each door,
and they are set to Interlocked mode. One door can be opened only when the two doors are closed. If a door has been
opened but not closed, another door cannot be opened. In addition, the operation of the interlock mode is the same as that
of the Single-mode mode.
4.5.5 Operation characteristics in Demo mode
Demo mode is a mode for Single-door mode, primarily for display purposes or without safety, as a tool to use any card to
open the door. In this mode, any card or 6-digit PIN can be opened without authorization. When entering management
mode, only menus 03, 09, 32, 34, 51-53 and 55 are valid.
5 Management menu summary table
5.1 Reader mode management menu summary table
Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) #
Menu
Parameter or operation step
Function
Default value
00
(New admin password) #, (Repeat new
admin password)
Change admin password
888888
01
0# ,read card, read card, …
Set 1-3 Set-cards
02
0#
Delete 3 Set-cards