The valid menus for Demo mode are: 03,09,32,34,51-53,55. 

4.1.6 Limits types of reading card 

04, 0#, cannot read any card. 
04, 1#, can read EM card only. 
04, 2#, can read HID card only. 
04, 3#, can read IC card only. 
04, 4#, can read EM+HID card. 
04, 5#, can read EM+IC card. 
04, 6#, can read HID+IC card. 
04, 7#, can read EM+HID+IC card. 

Note: Whether you can read a card is determined by the specific model and the codes above. 

4.1.7 Restore to default settings 

 

09, 0000# 

Note: After Restore to default settings, Admin Password is unchanged, Machine mode is unchanged, admin cards and user 
card information are not deleted, and the specific default values are shown in the appendix. 

4.1.8 Add User 

4.1.8.1 Automatically generates ID numbers to add user card 

Read card continuously to add user: 

10, read card, read card, … 

Input 8-digit format card number to add user 

10, 8# (8-digit format card number) #, 8# (8-digit format card number) #, … 

Input 10-digit format card number to add user: 

10,10# (10-digit format card number) #, 10# (10-digit format card number) #, … 

Note: For example, card number is: 0004301875, 065,42035, front numbers are 10-digit format card number, the following 
numbers are 8-digit card number, 00 in front of number can be omitted, you can input 4301875 or 65,42035. The card 
number not separated by commas or other symbols is considered as 10-digit format card number. The following sections are 
dealt with according to this rule. 

4.1.8.2

 

Specify ID number to add user card or PIN 

Specify ID number and read card to add user: 

11, (ID) #, read card, (ID) #, read card, … 

Specify ID number and input 8-digit card number to add user: 

11, (ID) # 8# (8-digit format card number) #, (ID) # 8# (8-digit format card number) #, … 

Specify ID number and input 10-digit format card number to add user: 

Содержание B6-EH Plus

Страница 1: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 1 B6 Plus USER MANUAL V1 0...

Страница 2: ...gement menu operation mode 15 3 8 User open door 15 4 Basic Functions 15 4 1 Management menu operations 15 4 1 1 Change Admin Password 15 4 1 2 Set or delete Super open password 16 4 1 3 Set admin car...

Страница 3: ...l open card operation 25 4 3 Users operation 25 4 3 1 Get user card or PIN 25 4 3 2 Change user PIN 25 4 3 3 User Open door 25 4 4 Other operations 26 4 4 1 Cancel alarming 26 4 4 2 Admin Password ini...

Страница 4: ...n set output format Support Card and PIN Multi cards to open the door Support Super open card and Super open password to open door Support Add card Delete card Anti duress card Authorization card and...

Страница 5: ...ndalone Access Controller B6 EH Plus EM HID Infrared 12 B6 IC Plus IC CPU Infrared 12 Single door Standalone Access Controller B6K EH Plus EM HID Own 12 B6K IC Plus IC CPU Own 12 Double doors Standalo...

Страница 6: ...elow The product wiring colors and functions are shown in the following table Color Symbol Functions Light green AC2 One port of the AC power supply Blue NO Normal open port of Relay Purple COM Common...

Страница 7: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 7...

Страница 8: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 8...

Страница 9: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 9...

Страница 10: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 10...

Страница 11: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 11...

Страница 12: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 12...

Страница 13: ...or parameter when you type this key it means input is finished means cancel current operation or back to previous menu Management menu fix to 2 digits from 00 99 Don t press on the menu behind after i...

Страница 14: ...does not sure about the mode please set it again the steps please follow 03 1 3 4 Set door opening time to 2S The factory default door opening time is 2S so if user request factory default time then...

Страница 15: ...r operation If the Admin Password is correct the indicator light will turn to green once and then back to red flash status Other operations must be performed in this status If the user forget the admi...

Страница 16: ...rd read card Set 1 3 Normal open cards Note Each type of admin card can be divided several times to set till to 3pcs 4 1 4 Delete admin card 02 0000 delete all 21 admin cards in this zone 02 0 delete...

Страница 17: ...ID numbers to add user card Read card continuously to add user 10 read card read card Input 8 digit format card number to add user 10 8 8 digit format card number 8 8 digit format card number Input 10...

Страница 18: ...at the same time till to all card is added In order to prevent duplication of card numbers please delete all user cards and admin cards before add serial number cards 4 1 9 Delete user Delete all user...

Страница 19: ...ble users to use Notes A better way to implement the limits of user mode is operation by Authorization card it can switch to disable and enable users to operate quickly The operation of Authorization...

Страница 20: ...10 45 1 99 default value is 10 set time locked after the error operation indicate maximum times from1 to 99minutes Note Anti crack function refers to prevent illegal and unlimited password or card cr...

Страница 21: ...only concern normal users operation such as the sound of opening door by PINs or read cards When you press the key for 2 seconds the buzzer is forced to enable such as entering the management menu or...

Страница 22: ...ut RS232 TTL HEX format 61 2 D0 output RS232 TTL ASCII 8 format 61 3 D0 output RS232 TTL ASCII 10 format Note The wiegand format is an international protocol for access control products But the width...

Страница 23: ...100 5 0101 6 0110 7 0111 8 1000 9 1001 1010 0 0000 1011 Single key output 6 bits wiegand data with parity bit E very key output a 6 bit data Corresponding relation is 1 000010 2 000100 3 000111 4 1010...

Страница 24: ...d indicate exiting add user card state 4 2 3 Delete card operation Read Delete card read user card read user card read Delete card Note Delete card is mainly used for rapid continuously to delete the...

Страница 25: ...by the user card The user card and the user PIN are divided into first zones and second zones they operate the door of the corresponding zone respectively The number of user PIN is specified zone 1 is...

Страница 26: ...it to the initial password by special operation Operation as follows Power off press the keys do not move and power on Release the key after two beep Admin password has restored to 888888 But the oth...

Страница 27: ...ting is the same with the zone 1 With 7 digit Admin Password into management mode only menus 00 01 02 10 12 21 22 30 36 are valid 4 5 4 Operation characteristics in Interlock mode Interlock mode is re...

Страница 28: ...me to 1 99 minutes 41 0 Disable Anti dismantle alarm 0 1 Enable Anti dismantle alarm 42 0 Alarm lead output alarm signal voltage 0 1 Alarm lead output doorbell signal voltage 50 0 Indicator light is a...

Страница 29: ...ts wiegand data no check bit 0 1 Single key output 6 bits wiegand data with parity bit 2 Single key output 8bits wiegand data with complement check bit 3 4 digit key buffered output 4 1 5 digit key ke...

Страница 30: ...ers 10 10 digit format card number 10 10 digit format card number Input 10 digit format card number to add users 11 ID read card ID read card Specify ID number and read card to add user ID 8 8 digit f...

Страница 31: ...t the alarm time to 0 means no alarm 0 1 99 Set the alarm time to 1 99 minutes 41 0 Disable anti dismantle alarm function 0 1 Enable anti dismantle alarm function 42 0 Alarm lead output alarm signal v...

Страница 32: ...tent as shown in the following table Way to enter menu Hold down for more than 2 seconds 2 Admin password Menu Parameter or operation step Function Default value 00 8 digit PIN Set super PIN 0000 Dele...

Страница 33: ...digit format number 8 8 digit format number Specified ID number and input 8 digit format card number to delete user 10 10 digit format number 10 10 digit format number Specified ID number and input 10...

Страница 34: ...ase the brightness of the backlit 55 1 1 Decrease the keypad tone 10 2 2 Increase the keypad tone 6 Precautions in use Lead line cannot be connected wrong especially the power line otherwise the machi...

Страница 35: ...password Change by Setting card or press the key to initialize Can enter management mode but part of the menu is invalid 1 can t setting some menu in default password only can change admin password Ch...

Отзывы: