Sebury B6-EH Plus Скачать руководство пользователя страница 34

 

B6  Plus  Series  Standalone  Access  Controller  User  Manual    V1.0 

Sebury Technology Co., Ltd

 

     

                                       

http://www.sebury.com.cn 

 

 

34

 

Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) # 

Menu  Parameter or operation step 

Function   

Default value 

2# 

Double-doors mode   

3# 

Interlock mode   

9# 

Demo mode   

09 

0000# 

Restore default settings, admin password and user 
information unchanged. 

 

32 

0# 

Set lock to Delay mode 

1# 

Set lock to Switch mode 

2# 

Set the lock to Normal-open mode 

34 

0# 

Set Open-time to 50mS 

(1-999)# 

Set Open-time from 1 to 999S 

51 

1,1,…,# 

Decrease the brightness of the normally bright red indicator 

18 

2,2,…,# 

Increase the brightness of the normally bright red indicator 

52 

0# 

Key backlit is always off 

1# 

Key backlit is always on 

(2-99)# 

After delay 2-99 seconds, Key backlit turn to micro light 

53 

1,1,…,# 

Decrease the brightness of the backlit   

14 

2,2,…,# 

Increase the brightness of the backlit 

55 

1,1,…,# 

Decrease the keypad tone   

10 

2,2,…,# 

Increase the keypad tone   

 

6 Precautions in use 

 

Lead line cannot be connected wrong, especially the power line, otherwise the machine may be burned or not work 
properly. 

 

Because the machine internal relay is used for signal output, cannot directly drive large power load, in order to ensure 
the long-term stable operation of the machine, the electric lock be not connected directly with NO, NC, COM of the 
machine, but driven by an access control special power supply. 

 

When you enter the management mode or change the user PIN, you must press and hold the * key for more than two 
seconds to be valid. 

 

Is for the sake of safety, the default admin initial password 888888 only support the menu 00, which forced users to 
change the 6-digit admin password, or cannot access other settings. 

 

The factory default mode is the single-door mode. If you need other mode functions, you must enter the appropriate 
mode to operate properly. In different modes, the management menu is also different. 
 

Содержание B6-EH Plus

Страница 1: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 1 B6 Plus USER MANUAL V1 0...

Страница 2: ...gement menu operation mode 15 3 8 User open door 15 4 Basic Functions 15 4 1 Management menu operations 15 4 1 1 Change Admin Password 15 4 1 2 Set or delete Super open password 16 4 1 3 Set admin car...

Страница 3: ...l open card operation 25 4 3 Users operation 25 4 3 1 Get user card or PIN 25 4 3 2 Change user PIN 25 4 3 3 User Open door 25 4 4 Other operations 26 4 4 1 Cancel alarming 26 4 4 2 Admin Password ini...

Страница 4: ...n set output format Support Card and PIN Multi cards to open the door Support Super open card and Super open password to open door Support Add card Delete card Anti duress card Authorization card and...

Страница 5: ...ndalone Access Controller B6 EH Plus EM HID Infrared 12 B6 IC Plus IC CPU Infrared 12 Single door Standalone Access Controller B6K EH Plus EM HID Own 12 B6K IC Plus IC CPU Own 12 Double doors Standalo...

Страница 6: ...elow The product wiring colors and functions are shown in the following table Color Symbol Functions Light green AC2 One port of the AC power supply Blue NO Normal open port of Relay Purple COM Common...

Страница 7: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 7...

Страница 8: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 8...

Страница 9: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 9...

Страница 10: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 10...

Страница 11: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 11...

Страница 12: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 12...

Страница 13: ...or parameter when you type this key it means input is finished means cancel current operation or back to previous menu Management menu fix to 2 digits from 00 99 Don t press on the menu behind after i...

Страница 14: ...does not sure about the mode please set it again the steps please follow 03 1 3 4 Set door opening time to 2S The factory default door opening time is 2S so if user request factory default time then...

Страница 15: ...r operation If the Admin Password is correct the indicator light will turn to green once and then back to red flash status Other operations must be performed in this status If the user forget the admi...

Страница 16: ...rd read card Set 1 3 Normal open cards Note Each type of admin card can be divided several times to set till to 3pcs 4 1 4 Delete admin card 02 0000 delete all 21 admin cards in this zone 02 0 delete...

Страница 17: ...ID numbers to add user card Read card continuously to add user 10 read card read card Input 8 digit format card number to add user 10 8 8 digit format card number 8 8 digit format card number Input 10...

Страница 18: ...at the same time till to all card is added In order to prevent duplication of card numbers please delete all user cards and admin cards before add serial number cards 4 1 9 Delete user Delete all user...

Страница 19: ...ble users to use Notes A better way to implement the limits of user mode is operation by Authorization card it can switch to disable and enable users to operate quickly The operation of Authorization...

Страница 20: ...10 45 1 99 default value is 10 set time locked after the error operation indicate maximum times from1 to 99minutes Note Anti crack function refers to prevent illegal and unlimited password or card cr...

Страница 21: ...only concern normal users operation such as the sound of opening door by PINs or read cards When you press the key for 2 seconds the buzzer is forced to enable such as entering the management menu or...

Страница 22: ...ut RS232 TTL HEX format 61 2 D0 output RS232 TTL ASCII 8 format 61 3 D0 output RS232 TTL ASCII 10 format Note The wiegand format is an international protocol for access control products But the width...

Страница 23: ...100 5 0101 6 0110 7 0111 8 1000 9 1001 1010 0 0000 1011 Single key output 6 bits wiegand data with parity bit E very key output a 6 bit data Corresponding relation is 1 000010 2 000100 3 000111 4 1010...

Страница 24: ...d indicate exiting add user card state 4 2 3 Delete card operation Read Delete card read user card read user card read Delete card Note Delete card is mainly used for rapid continuously to delete the...

Страница 25: ...by the user card The user card and the user PIN are divided into first zones and second zones they operate the door of the corresponding zone respectively The number of user PIN is specified zone 1 is...

Страница 26: ...it to the initial password by special operation Operation as follows Power off press the keys do not move and power on Release the key after two beep Admin password has restored to 888888 But the oth...

Страница 27: ...ting is the same with the zone 1 With 7 digit Admin Password into management mode only menus 00 01 02 10 12 21 22 30 36 are valid 4 5 4 Operation characteristics in Interlock mode Interlock mode is re...

Страница 28: ...me to 1 99 minutes 41 0 Disable Anti dismantle alarm 0 1 Enable Anti dismantle alarm 42 0 Alarm lead output alarm signal voltage 0 1 Alarm lead output doorbell signal voltage 50 0 Indicator light is a...

Страница 29: ...ts wiegand data no check bit 0 1 Single key output 6 bits wiegand data with parity bit 2 Single key output 8bits wiegand data with complement check bit 3 4 digit key buffered output 4 1 5 digit key ke...

Страница 30: ...ers 10 10 digit format card number 10 10 digit format card number Input 10 digit format card number to add users 11 ID read card ID read card Specify ID number and read card to add user ID 8 8 digit f...

Страница 31: ...t the alarm time to 0 means no alarm 0 1 99 Set the alarm time to 1 99 minutes 41 0 Disable anti dismantle alarm function 0 1 Enable anti dismantle alarm function 42 0 Alarm lead output alarm signal v...

Страница 32: ...tent as shown in the following table Way to enter menu Hold down for more than 2 seconds 2 Admin password Menu Parameter or operation step Function Default value 00 8 digit PIN Set super PIN 0000 Dele...

Страница 33: ...digit format number 8 8 digit format number Specified ID number and input 8 digit format card number to delete user 10 10 digit format number 10 10 digit format number Specified ID number and input 10...

Страница 34: ...ase the brightness of the backlit 55 1 1 Decrease the keypad tone 10 2 2 Increase the keypad tone 6 Precautions in use Lead line cannot be connected wrong especially the power line otherwise the machi...

Страница 35: ...password Change by Setting card or press the key to initialize Can enter management mode but part of the menu is invalid 1 can t setting some menu in default password only can change admin password Ch...

Отзывы: