B6 Plus Series Standalone Access Controller User Manual V1.0
Sebury Technology Co., Ltd
http://www.sebury.com.cn
第
19
页
4.1.12 Set lock working mode
32, 0#, default value, set lock to Delay mode. After an unlock operation, the lock is opened , then the lock will be closed
automatically after a few moment of delay. Apply to normal open.
32, 1#, set lock to Switch mode. After an unlock operation, the lock will keep opening until another unlock operation
again, the lock will keep locking, and so on.
32, 2#, set lock to Normal-open mode. Under this mode, the lock will keep opening, not controlled by other unlocking
action. If the user don’t want to use the Normal-open mode, please set the mode to the other two modes.
Note: A better way to implement the Normal-open mode is operation by Normal-open card in the first mode, it can switch to
Normal-open mode and normal status quickly. The operation of Normal-open card, see relevant chapter of admin cards
operation.
4.1.13 Set Limits User Mode
33, 0#, disable users to use.
33, 1#, default value, enable users to use.
Notes: A better way to implement the limits of user mode is operation by Authorization-card, it can switch to disable and
enable users to operate quickly. The operation of Authorization-card, see relevant chapter of admin cards operation.
4.1.14 Set Open-time
34, 0#, set Open-time to 50mS, apply to electrically controlled lock for external instantaneous large current
34, (1-999) #, the default value is 2, set Open-time from 1 to 999S.
Note: Unlock-time of Access Controller’s special power supply should set to min time to ensure the actual Unlock-time match
with user’s settings.
4.1.15 Set notification to close door
35, (0-99) #, the default value is 10, set the time that notify when user not close the door after opened it. It can be set to
after more than (how many) second the buzzer begin to beep for notification.
36, (0-99) #, the default value is 10, set the time for beeping.
Note: If you don’t need notification, can set the time for warning to 0.
4.1.16 Set Alarm-time
40, 0#, default value, if set Alarm-time to 0 means no alarm.
40, (0-99) #, Alarm-time is set from 1 to 99 minutes.
4.1.17 Set Anti-dismantle alarm function
41, 0#, default value, disable Anti-dismantle alarm function.
41, 1#, enable Anti-dismantle alarm function.