Changing the battery
85
13
Changing the battery
13.1
Ordering a battery-replacement kit
Used batteries can be replaced. You will need a special battery replacement kit, which is
available from SebaKMT.
Compare the first 8 digits of the type key on the logger's nameplate with the information
in the following tables. Select the appropriate battery-replacement kit and state the item
number when ordering.
Battery-replacement kits for devices with internal GSM modem:
Type key of the device
Item number of the battery-replacement kit
LOG D-3 4 G
90016461
LOG D-3 2 G
90016464
Battery-replacement kits for devices without GSM modem:
Type key of the device
Item number of the battery-replacement kit
LOG D-3 4
90016463
LOG D-3 2
90016466
If you are not sure which kit to choose, please contact your SebaKMT service partner or
contact us. Contact information on our web site
www.sebakmt.com
.
Each replacement kit contains new O-ring seals for the logger housing and the logger lid
in addition to the batteries. Replacing the seals in the course of the battery change is
mandatory.Otherwise, the tightness of the device is compromised.
13.2
Conduct the replacement
Stored measurement data may get lost due to the battery change. Therefore, it is
recommended to read and save the logger's measurement data to the computer prior to
the battery replacement.
To conduct the battery change, proceed as follows.
NOTE
Please be careful not to damage any parts. Don't use any force.
Step Description
1
The device needs to be turned off.
2
Loosen the six screws of the device.
3
Loosen and remove the lid of the device. Do not use any tools as an aid, even
not if the lid seems to be stuck.
Result:
Inside the device you have access to the batteries.
(continued on the next page)
Get a battery
replacement kit
Spare seal rings
supplied
Back up data
Replace batteries
Содержание Sebalog D-3
Страница 2: ...Consultation with SebaKMT 2...
Страница 8: ...Terms of Warranty 8...
Страница 26: ...Commissioning the logger 26...
Страница 34: ...Connecting the logger and installing it on site 34...
Страница 70: ...Programming the logger using the SebaDataView 3 software 70...
Страница 78: ...Retrieving and evaluating data 78...
Страница 88: ...Changing the battery 88...