background image

Technical description 

 

 

13 

2.4 

Scope of delivery 

The basic set comprises the following devices and accessories:  

Accessory 

Description 

Art.no. 

COR C-300-RI 

USB interface 

1008480 

COR PT-3A 

Power transmitter A  

1004779 

COR PT-3B 

Power transmitter B 

1004780 

PAM CORR-2 

2 x active universal microphone for PT-3 

820019615 

LG  C-3 

Charging unit for CPK 3/CMK 3 

1006646 

LK  13 

Car charging adaptor, 3.5m 

810000006 

KR 22-5 

Stereo headphones 

810002087 

VST T-1 

2 x extension rod for PAM CORR-2 

810000103 

 

2 x nylon cord 3mm blue, 2m 

304035025 

CSW CorreluxView  

PC software 

1006584 

 

The following devices and accessories are available to extend the basic set. 

Accessory 

Description 

Art.no. 

COR MS-3 

Multi sensor 

1004815 

CMK 3-8-MS 

Case for 8 Multi sensors COR MS-3 

2005301 

LOG TP 

Trivet adaptor for Sebalog Corr 

128309877 

LOG MWA 

Magnetic angled adaptor 

118303355 

 

Mounting set for COR MWA 

(Screws for angled adapters) 

2007393 

 

Set of labels COR MS-3 (1 - 8) 

2007321 

 

Correlux C-300-RI is specified by the following parameters: 

dimensions 

170 x 110 x 60 mm (without antenna) 

Weight 

0.6 kg 

Connector / Supply 

USB 

 

Parameter 

Value 

Sensor 

Piezo sensor with active amplifier (standard) /  

hydrophone (optional) 

Indicators 

I/O LED (device On/Off) 
Radio LED (radio module On/Off)) 
Row of LEDs (battery status or measured noise level) 

Operation 

On/Off pushbutton 

Power supply 

Internal rechargeable Li-Ion battery, 

inductive charging 

Standard accessory 

Additional accessory 

Technical data 

Power transmitter  

COR PT-3A/B 

Содержание COR C-300-RI

Страница 1: ...sue 0 9 03 2017 EN Article number 88888 Mess und Ortungstechnik Measuring and Locating Technologies Elektrizit tsnetze Power Networks Kommunikationsnetze Communication Networks Rohrleitungsnetze Water...

Страница 2: ...Consultation with SebaKMT 2...

Страница 3: ...ervice station please contact Seba Dynatronic Mess und Ortungstechnik GmbH Hagenuk KMT Kabelmesstechnik GmbH Dr Herbert Iann Str 6 D 96148 Baunach Phone 49 9544 68 0 Fax 49 9544 22 73 R deraue 41 D 01...

Страница 4: ...MT are hereby limited to a period of 12 months from the date of delivery Each component supplied by SebaKMT within the context of warranty will also be covered by this warranty for the remaining perio...

Страница 5: ...and Design 17 4 2 Identification number ID 19 4 3 Power supply 19 4 4 Commissioning 20 4 5 Installation 20 5 The Multi sensors 21 5 1 Design and function 21 5 2 Identification number ID 21 5 3 Power s...

Страница 6: ...lation 31 6 6 1 Perform and display a correlation 31 6 6 2 Display and select audio blocks Offline measurements only 32 6 6 3 Call up the correlation analysis menu 33 6 6 4 Select a correlation method...

Страница 7: ...Terms of Warranty 7...

Страница 8: ...e to non observance of the instructions and safety advices provided by this manual Locally applying regulations have to be observed The following signal words and symbols are used in this manual and o...

Страница 9: ...s designed for industrial use When used at home it could cause interference to other equipment such as the radio or television The interference level from the line complies with the limit curve B livi...

Страница 10: ...nline measurement In a so called Online measurement the noise recording and the correlation of the data take place at the same time Step Description 1 Installing the Power transmitters A and B at two...

Страница 11: ...e leak noise directly at the water column The Transport case offers space for the C 300 RI 2 Power transmitters and 3 Multi sensors The case is not only for storage and transportation purposes but als...

Страница 12: ...by the vehicle s battery even while the vehicle is not in operation This could result in the complete discharge of the vehicle battery When you park the car disconnect the Correlux transport case from...

Страница 13: ...sic set Accessory Description Art no COR MS 3 Multi sensor 1004815 CMK 3 8 MS Case for 8 Multi sensors COR MS 3 2005301 LOG TP Trivet adaptor for Sebalog Corr 128309877 LOG MWA Magnetic angled adaptor...

Страница 14: ...al description 14 Parameter Value Operating time min 12 h Connections Sensor microphone hydrophone Radio antenna Dimensions without handle 125 x 111 mm Weight without sensor 0 9 kg Degree of protectio...

Страница 15: ...ht 0 4 kg Degree of protection IP 68 Parameter Value Sensor Integrated piezo sensor with active amplifier Adapter Magnetic adaptor Indicators Status LED Operation On Off magnetic switch Power supply I...

Страница 16: ...ors COR MS 3 and receive the analog signal of the Power Transmitters COR PT 3 The C 300 RI has two external connectors to connect two different antennas one for digital communication and one for long...

Страница 17: ...o module and an analogue radio module with antenna inside The sensors have the following external characteristics Element Description Microphone storage place Sensor socket for connecting the micropho...

Страница 18: ...the noise level I O LED lit green the transmitter is switched on flashing the device is charging not lit the transmitter is switched off Radio LED lit red the transmitter is in Active mode noise meas...

Страница 19: ...one of five LEDs is lit the device should be charged Otherwise it switches itself off automatically Red light represents the recorded noise during the measurement and not the battery status The Power...

Страница 20: ...s the microphone is taken from the storage place the Power transmitter switches from Stand by to Active mode The radio module is activated From now on the recorded data are directly sent to the Correl...

Страница 21: ...y Device is charging no light Device is turned off ON OFF contact area I O Magnetic foot detachable Type plate Carrying ring detachable 5 2 Identification number ID Each Multi sensor has its own six d...

Страница 22: ...rage places in the case they are recharged inductively Charging takes approximately 6 hours The units indicator lights are rapidly flashing during the charging process The indicator lights turn to per...

Страница 23: ...the sensor is simply placed on the adapter Then the magnetic adapter can be attached to the pipe or fitting etc NOTE The sensor s type plate and I O area must face away from the angle adapter as can b...

Страница 24: ...The Multi sensors 24...

Страница 25: ...ately into different segments The CorreluxView symbol at the top left of the menu bar allows you to access system settings for the application The directory structure the so called directory tree of t...

Страница 26: ...Button for deleting this sensor from the list Button for listening to the quietest recording made by this sensor Minimum value of this sensor ESA value level in dB frequency in Hz The color of the fi...

Страница 27: ...CorreluxView application by the Correlator are saved under this location You can use the Open button to open the directory You can use the Browse button to specify a new storage location The applicat...

Страница 28: ...naming and deleting directories To create a new directory in the directory tree proceed as follows Step Description 1 In the directory tree select the directory under which your new directory is to be...

Страница 29: ...surement is to be added If necessary first create a new directory 3 Click on Import in the menu bar Result A new window opens 4 Navigate to the Correlator s root directory CORRELUX This directory will...

Страница 30: ...nd click on it Result A line will now connect the two sensor icons on the screen A window opens allowing you to enter parameters for the new pipeline 4 You can use the Add and Delete buttons to divide...

Страница 31: ...dy be familiar with these correlation diagrams from your work with the Correlator The frequency diagram at the very top of the screen allows you to set a frequency filter and to repeat the correlation...

Страница 32: ...ng the 10 checkboxes on the right you have the chance to exclude from the overall correlation those individual audio block correlations which are unusable To do this just deactivate the checkbox next...

Страница 33: ...elation The buttons for analyzing correlation curve and coherence will probably also be familiar to you from your work with the Correlator Zoom To magnify a section of the correlation curve Click on t...

Страница 34: ...open the printer dialog window Using the radio buttons in the Show segment bottom right you can select whether the two sensors left and right of the correlation curve are described by their Sensor num...

Страница 35: ...triche vecchie z me nor da ka iztr d jumu uz kura t atrodas nedr kst izmest kop ar parastiem m jsaimniec bas atkritumiem T k tas ir izstr d jums ko cits citam p rdod un lieto tikai uz mumi tad to nedr...

Отзывы: