15 Rev. 1.2 13/01/2021
FC AP2 ( Safe opening ) :
If the device trips during closing, it is ignored. If it trips
during opening, it Stops + gate motion is reversed for 2
sec.
FC CH1 ( Safe closing ) :
If the device trips during opening and closing, it always
Stops + gate motion is reversed for 2 sec.
FC CH2 ( Safe opening and closing ) :
If the device trips during opening, it Stops + gate motion is
reversed for 2 sec. If it trips during closing, gate motion is
reversed.
Warning:
Jumper if some of these inputs used as Safety
Devices are not used.
C3) PUL and PED Input Selection:
The control unit is factory supplied with PUL control input
operation for the connection of a cyclical primary control
button (NA) and a PED input for the connection of a
cyclical Pedestrian command button (NA). If you want to
select another operating mode for the PUL and PED
inputs, proceed as follows: set SEL and SET to display
C3
then press SET to select the function. At the same time
DOT 1
will start to flash, press SET to change the
function,
DOT 2
will remain permanently lit and the
operation will be complete.
Repeat
the
procedure
to
restore
the
previous
configuration.
Accordingly, the PUL input makes it possible to connect a
button (NA) for the Opening phase only, and the PED
input for connection to a button (NA) for the Closing phase
only.
C4) PRE-FLASHING
The control unit is supplied by the manufacturer with the
Pre-flashing function disabled. If you want to enable the
function, proceed as follows: set SEL and SET to display
C4
then press SET to select the function. At the same
time
DOT 1
will start to flash, press SET to change the
function,
DOT 2
will remain permanently lit and the
operation will be complete.
Repeat
the
procedure
to
restore
the
previous
configuration.
This way, the flashing beacon output is always activated 3
seconds before automation starts any type of motion.
C5) COURTESY LIGHT:
The control unit is supplied by the manufacturer with the
Courtesy Light disabled. If you want to enable the
function, proceed as follows: set SEL and SET to display
C5
then press SET to select the function. At the same
time
DOT 1
will start to flash, press SET to change the
function,
DOT 2
will remain permanently lit and the
operation will be complete.
Repeat
the
procedure
to
restore
the
previous
configuration.
This way, the Flashing beacon output will be activated for
3 minutes, each time that an opening command is given.
C6) FLASHING LIGHT FUNCTION EVEN IN DELAY:
The control unit is supplied by the manufacturer with the
flashing beacon function during the Pause Time disabled.
If you want to enable operation, proceed as follows: set
SEL and SET to display
C6
then press SET to select the
function. At the same time
DOT 1
will start to flash, press
SET to change the function,
DOT 2
will remain
permanently lit and the operation will be complete.
Repeat
the
procedure
to
restore
the
previous
configuration.
C7) DECELERATION:
The control unit is supplied by the manufacturer with the
Deceleration function enabled. If you want to disable the
function, proceed as follows: set SEL and SET to display
C7
then press SET to select the function. At the same
time
DOT 1
will start to flash, press SET to change the
function,
DOT 2
will remain permanently lit and the
operation will be complete.
Repeat
the
procedure
to
restore
the
previous
configuration.
C8) DS1 PHOTOCELL TEST:
The control unit is supplied by the manufacturer with the
DS1 Photocell Test disabled. If you want to enable the
function (in accordance with standard EN 12453), proceed
as follows: set SEL and SET to display
C8
then press SET
to select the function. At the same time
DOT 1
will start to
flash, press SET to change the function,
DOT 2
will
remain permanently lit and the operation will be complete.
In this way, the test will be carried out on the Phot ocell
connected to input DS1 before automation starts any
movement. Repeat the procedure to restore the previous
configuration.
.
C9) DS2 PHOTOCELL TEST:
The control unit is supplied by the manufacturer with the
DS2 Photocell Test disabled. If you want to enable the
function (in accordance with standard EN 12453), proceed
as follows: set SEL and SET to display
C8
then press SET
to select the function. At the same time
DOT 1
will start to
flash, press SET to change the function,
DOT 2
will
remain permanently lit and the operation will be complete.
In this way, the test will be carried out on the Photocell
connected to input DS2 before automation starts any
movement. Repeat the procedure to restore the previous
configuration.
PASSWORD : “ PS “ Enter / Delete
After programming the control unit, it is possible to
memorise a numerical password to disable or enable
programming of the control unit, as follows: set the SEL
key to display
PS
then press SET to select the function. At
the same time,
DOT 1
will start to flash, press SEL and
scroll through Digit 1 and 2 from 00
– 99 as desired. After
selecting the number, press SET,
DOT 2
will remain lit
permanently and the operation will be complete. From this
moment on, you may view the stored settings but you
cannot change them.
To remove the Password previously entered and modify
the control unit settings, set the SEL key to display
PS
then press SET to select the function. At the same time,
DOT 1
will start to flash, press SEL and scroll through
Digit 1 and 2 from 00
– 99 according to the password
previously set. After selecting the number, press SET,
DOT 2
will go off permanently and the operation will be
complete.
Repeat the above operation to enter a new Safety
Password.
Important:
if you enter a wrong password you have to
wait 5 minutes to repeat the operation and then 1 hour.
RESET : ” RC “ RESET RADIO CONTROL CODES
If you only need to delete all Radio control codes present,
proceed as follows:
set SEL to display
RC
then press SET to select the
function. At the same time,
DOT 1
will start to flash, press
SET continuously for minimum 5 seconds for
DIGIT 1
and
DIGIT 2
to display
“ – – “
and the operation will be
complete.
Attention:
This operation does not disable the rule of the first
pre-existing radio control, if it is necessary to disable it it will be