Rev. 3.0 13 – 06 - 2016
10
F
OR THE
U
SER
-
I
MPORTANT
- The device should not be used by children or by individuals
with reduced physical or psychological abilities unless
supervision is provided or instruction given on how to operate it.
- Do not let children play with the device; keep radio controls out
of their reach.
- CAUTION: Keep this instruction manual in a safe place and
adhere to the important safety instructions contained within it.
Non-adherence to these instructions may lead to property
damage and serious accidents.
- Examine the system frequently to check for any signs of
damage. Do not use the device if it needs to be repaired.
Warning
All operations which require the casing to be opened (such as
wire connection, programming, etc.) must be carried out during
installation, by skilled staff only. For any other procedure which
requires the casing to be opened again (re-programming,
repairs or site modifications), please contact the technical
assistance service.
N
OTES FOR THE
I
NSTALLER
The control unit was designed for installation with other
components (motor, shutter or gate, safety devices) in order
to form a finished product (machine) in compliance with the
Machines Directive.
The safety of the final installation site and adherence to all
current legislation is the responsibility of the individual
assembling the various parts to construct a complete closure
device.
We advise that you also take note of the following
recommendations:
−
Before shutter automation, it is necessary to check the
product is in good condition and that it complies with EN
12604 and the Machines Directive.
−
The wiring of external electrical components must comply
with EN 60204-1 as amended in section 5.2.7 of EN
12453. Power supply leads and connection cables must
be secured through the use of cable clamps, which are
supplied with the product.
−
The motor reducer used to move the shutter must comply
with section 5.2.7. of EN 12453.
−
If present, the keypad for manual control must be mounted
in such a way that the user is not placed in a dangerous
situation, in compliance with point 5.2.8 of EN 12453.
−
The control unit is not equipped with a 230 V a/c electric
line sectioning device. The installer is responsible for
installing a sectioning device in the system. An omnipolar
switch with overheating category III must be installed.
The sectioning device must be positioned so that it is
protected against accidental closure, in compliance with
section 5.2.9 of standard EN 12453.
−
In compliance with EN 12453 it is recommended that
motor reducers fitted with an electromechanical unlocking
device are used, so that the door can be moved manually
if necessary.
−
In compliance with point 5.4.3 of EN 12453,
electromechanical unlocking systems or similar devices
should be used as these enable the door to stop safely at
its stop limit.
−
Power supply and motor connection cables which are
suitable for use in conjunction with the pg9 cable clamps
provided must have an external diameter with a
measurement between 4.5 and 7 mm. The internal
conductor wires must have a nominal cross-section of
0.75 mm².
If a channel is not used, we recommend that
cables in H05RR-F material are used.
−
The D.S. Power Supply outlet must be dedicated to the
powering of devices connected to DS1 and DS2
(photoelectric cells for example); other applications are
not permitted. A test may be performed using the control
unit at the beginning of every manoeuvring cycle to make
sure operation is taking place correctly. If several of the
abovementioned devices are used, they must be
connected in series.
We recommend the use of a safety device with NC
output, which is capable of monitoring its own correct
operation and which conforms to regulation EN 12978.
−
Once installation is complete, all the checks listed in EN
12453 – EN 12445 must be performed so as to ensure
that closure occurs in compliance with all stipulations.
−
For the radio receiver to operate correctly when two or
more control units are used, we recommend that you
install the devices at least 3 metres away from each
other.
SEAV s.r.l.
hereby declares that the below products:
Electronic Control Unit:
LG 2205 - LRS 2205 - LRS 2205 SET - LRH 2205
conform to the specifications in the Directives
RED 2014/53/EU, EMC 2014/30/EU, LVD 2014/35/EU.