background image

MAINTENANCE

Pump and piping need not be disconnected to repair or re-
place motor or seal (see Figure 16). If motor is replaced, re-
place the shaft seal (Key No. 6, Page 11). Keep one on hand
for future use.
Be sure to prime pump before starting.

NOTICE:

Check motor label for lubrication instructions.

The mechanical shaft seal in the pump is water lubricated
and self-adjusting.

NOTICE:

Drain pump when disconnecting from service or

when it might freeze.

PUMP DISASSEMBLY

1. Disconnect power to motor.

NOTICE:

Mark wires for correct assembly.

2. Remove clamp (see Figure 16).
3. Remove pump base mounting bolts. Motor assembly and

back half of pump can now be pulled away from pump
front half (Figure 16). CAREFULLY remove O-Ring.

CLEANING/REPLACING IMPELLER

NOTICE:

First, follow instructions under “Pump Disas-

sembly”.
1. Remove four screws fastening diffuser to seal plate; re-

move diffuser (see Figure 17). Exposed impeller can now
be cleaned.

2. If impeller must be replaced, loosen two machine screws

and remove motor canopy (see Figure 18).

3.

Capacitor voltage may be hazardous.

To discharge capacitor, hold insulated handle screw-
driver 

BY THE HANDLE

and short capacitor terminals

together (see Figure 18). Do not touch metal screwdriver
blade or capacitor terminals. If in doubt, consult a quali-
fied electrician.

4. Unscrew capacitor clamp and remove capacitor. Do not

disconnect capacitor wires to motor.

5. Slide 7/16” open end wrench in behind spring loaded

switch on motor end of shaft; hold motor shaft with
wrench on shaft flats and unscrew impeller by turning
counterclockwise when looking into eye of impeller.

6. To reinstall, reverse steps 1 through 5.
7. See directions under “Pump Reassembly,” Page 10.

REMOVING OLD SEAL

1. Follow instructions under “Pump Disassembly”.
2. Follow steps 2 through 5 under “Cleaning/Replacing

Impeller.

3. Unscrew four nuts holding pump back half to motor.

Remove rotating half of seal by placing two screwdrivers
under back half of pump body and carefully prying up
(Figure 19). Back half of pump body will slide off shaft,
bringing seal with it.

NOTICE:

Be sure you do not scratch or mar shaft; if shaft is

marred, it must be dressed smooth with fine emery or cro-
cus cloth before installing new seal. DO NOT reduce shaft
diameter!

8

845 0494

844 0494

Figure 18 – Hold Shaft

To avoid electrical
shock hazard, use
insulated-handle
screwdriver to short
capacitor terminals
as shown.

Figure 16 – Slide Motor Back

Figure 15 – Disconnect Power

Figure 17 – Remove Diffuser

889 0494

Figure 19 – Remove Seal plate

Содержание HYDRO-GLASS 390.262452

Страница 1: ...Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Maintenance Repair...

Страница 2: ...art fires 5 Disconnect electrical power source before installing or working on pump 6 Ground pump with a ground wire run from grounding lug on motor to a grounded lead in the service panel 7 Line volt...

Страница 3: ...void the warranty Check locally for frost protection requirements usually pipe must be 12 below frost line and pump must be insu lated 4 Be sure all pipes and foot valve are clean and in good shape 5...

Страница 4: ...ON 1 Connect the suction pipe to the drive point as illustrated in Figure 6 Keep horizontal pipe run as short as possible Use Teflon tape on male pipe threads Multiple well points may be necessary to...

Страница 5: ...pump 4 Tighten joints hand tight plus 1 1 2 turns Do not over tighten NOTICE Install pump as close to water source as possible Long piping runs and many fittings create friction and re duce flow Use...

Страница 6: ...d copper wire at least as large as power sup ply wires Connect ground wire to grounded lead in service panel metal underground water pipe well casing at least 10 3M long or to ground electrode provide...

Страница 7: ...tal run 10 of horizontal suction pipe 1 of vertical lift due to friction losses in the pipe If no water is produced within 10 minutes stop pump release all pressure remove priming plug refill and try...

Страница 8: ...terminals together see Figure 18 Do not touch metal screwdriver blade or capacitor terminals If in doubt consult a quali fied electrician 4 Unscrew capacitor clamp and remove capacitor Do not disconn...

Страница 9: ...arbon face of seal when passing it over threaded shaft end or shaft shoulder The carbon surface must remain clean or short seal life will result 9 Hold motor shaft with 7 16 open end wrench on shaft f...

Страница 10: ...and re prime If receding water level of pump in well exceeds suction lift a deep well pump is needed 3 Impeller is plugged 3 Clean impeller see Maintenance 4 Check valve or foot valve is stuck 4 Repla...

Страница 11: ...784 2784 2784 7 Impeller C105 92PVB C105 92PBBB C105 214PFA Impeller Screw C30 51SS 8 Diffuser C1 258PCA C1 258PCA 8A Diffuser C1 274P 9 Screw 8 32 RH U30 869SS U30 869SS U30 542SS 1 and 1 1 2 HP 4 Re...

Страница 12: ...reement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES America s Repair S...

Отзывы: