INTRODUCTION

Please take a few minutes to read our instructions before you
install and use your pump. This will help you obtain the full
benefits from this pump. It will also help you avoid any need-
less service costs that result from causes we cannot control
and cannot cover in our warranty.

Carefully read and follow all safety instructions in this
manual or on pump.

This is the safety alert symbol.

When you see this

symbol on your pump or in this manual, look for one of the
following signal words and be alert to the potential for per-
sonal injury!

DANGER 

warns about hazards that will cause

serious personal injury, death or major property damage if
ignored.

WARNING 

warns about hazards that can

cause serious personal injury, death or major property dam-
age if ignored.

CAUTION 

warns about hazards that will or

can cause minor personal injury or property damage if ig-
nored.

The word 

NOTICE 

indicates special instructions which are

important but not related to hazards.

1. To avoid risk of serious bodily injury and property dam-

age, read safety instructions carefully before installing
pump.

2. Follow local and/or national plumbing and electrical

codes when installing pump.

3. Keep the well covered while installing pump to prevent

leaves and other debris from falling into well, contami-
nating well and possibly damaging pump.

4. Protect pump and piping system from freezing. Allowing

pump or water system to freeze could severely damage
pump and voids warranty.

Hazardous Voltage. Can shock, burn,

cause death, or start fires.

5. Disconnect electrical power source before installing or

working on pump.

6. Ground pump with a ground wire run from grounding lug

on motor to a grounded lead in the service panel.

7. Line voltage and frequency of electrical power supply

must agree with motor nameplate.

8. Use of fuses or wire smaller than size recommended in

owner’s manual can cause overheating, possible fires, and
will void warranty.

9. Pump water only with this pump.

10. Do not run pump dry. To do so will damage seals and can

cause leaking and property damage.

FULL ONE YEAR WARRANTY ON PUMPS

For one year from the date of purchase, Sears will repair or replace this pump, free of charge, if defective in material or work-
manship.

LIMITED WARRANTY ON SEARS HYDRO-GLASS

®

PUMPS

After one year and through two years from the date of purchase, Sears will furnish, free of charge, a replacement part for any
defective part. You pay for labor.

This warranty does not cover repairs or replacement parts necessary because of abuse or negligence including failure to in-
stall, adjust and operate this pump according to the instructions in the owner’s manual.

LIMITATION OF  WARRANTY

SEARS WILL NOT BE LIABLE FOR LOSS OR DAMAGE TO PROPERTY OR ANY INCIDENTAL OR CONSEQUENTIAL
LOSS OR EXPENSE FROM PROPERTY DAMAGE DUE DIRECTLY OR INDIRECTLY FROM THE USE OF 
THIS PRODUCT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclu-
sion may not apply to you.

WARRANTY SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER/DEPART-
MENT IN THE UNITED STATES. This warranty applies only while the product is in use in the United States.

This warranty gives you specific legal rights, and you may also have other rights which vary from  state to state.

Sears, Roebuck and Co., Dept. 817 WA, Hoffman Estates, IL 60179

RULES FOR SAFE INSTALLATION AND OPERATION!

Содержание HYDRO-GLASS 390.262452

Страница 1: ...Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Maintenance Repair...

Страница 2: ...art fires 5 Disconnect electrical power source before installing or working on pump 6 Ground pump with a ground wire run from grounding lug on motor to a grounded lead in the service panel 7 Line volt...

Страница 3: ...void the warranty Check locally for frost protection requirements usually pipe must be 12 below frost line and pump must be insu lated 4 Be sure all pipes and foot valve are clean and in good shape 5...

Страница 4: ...ON 1 Connect the suction pipe to the drive point as illustrated in Figure 6 Keep horizontal pipe run as short as possible Use Teflon tape on male pipe threads Multiple well points may be necessary to...

Страница 5: ...pump 4 Tighten joints hand tight plus 1 1 2 turns Do not over tighten NOTICE Install pump as close to water source as possible Long piping runs and many fittings create friction and re duce flow Use...

Страница 6: ...d copper wire at least as large as power sup ply wires Connect ground wire to grounded lead in service panel metal underground water pipe well casing at least 10 3M long or to ground electrode provide...

Страница 7: ...tal run 10 of horizontal suction pipe 1 of vertical lift due to friction losses in the pipe If no water is produced within 10 minutes stop pump release all pressure remove priming plug refill and try...

Страница 8: ...terminals together see Figure 18 Do not touch metal screwdriver blade or capacitor terminals If in doubt consult a quali fied electrician 4 Unscrew capacitor clamp and remove capacitor Do not disconn...

Страница 9: ...arbon face of seal when passing it over threaded shaft end or shaft shoulder The carbon surface must remain clean or short seal life will result 9 Hold motor shaft with 7 16 open end wrench on shaft f...

Страница 10: ...and re prime If receding water level of pump in well exceeds suction lift a deep well pump is needed 3 Impeller is plugged 3 Clean impeller see Maintenance 4 Check valve or foot valve is stuck 4 Repla...

Страница 11: ...784 2784 2784 7 Impeller C105 92PVB C105 92PBBB C105 214PFA Impeller Screw C30 51SS 8 Diffuser C1 258PCA C1 258PCA 8A Diffuser C1 274P 9 Screw 8 32 RH U30 869SS U30 869SS U30 542SS 1 and 1 1 2 HP 4 Re...

Страница 12: ...reement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES America s Repair S...

Отзывы: