NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
important:
no liability is accepted for incorrect use of this product.
WarrantY:
Guarantee is 12 months from purchase date, proof of which will be required for any claim.
sole uK distributor, sealey Group.
K
empson Way, Suffolk Business Park,
B
ury st. edmunds, suffolk.
i
P32 7AR
www.sealey.co.uk
01284 757500
01284 703534
Web
environmental protection
recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,
taken to a recycling centre and disposed of in a manner which is compatible with the environment.
Weee regulations
d
ispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic
Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way.
contact your local solid waste authority for recycling information.
7.2.5.
store device in a frost-free room (at least 5 °c).
8. troubleshooting
fault
cause
remedy
Pump does not work
no power supply
check power cable, plug, supply
motor overheat due to high liquid
temperature
eliminate cause of overheating (max. liquid temperature is 35°c)
motor overheats due to blocked
ventilation slots
eliminate cause of overheating
residual current device activated
reset
motor defective
contact dealer
delivery rate too slow
W
ater shortage
e
nsure sufficient water supply
not enough pressure
suction pipe not sealed
seal suction pipe, tighten screwed connections
delivery rate too slow
suction height too high
observe maximum suction height 8mtr.
suction height must be deducted from the conveyance height.
filter blocked or soiled
c
lean or replace filter
check valve blocked
clean or replace valve
W
ater leak between motor and pump,
shaft sealing not sealed
contact dealer
Pump is blocked or defective
clean pump with clean water and remove the cause of the
contamination
Air in the pump or suction pipe
fill pump case with water.
f
or suction pipes with a check valve, fill the suction pipe with water
Pressure switch faulty
contact dealer
suction pipe sucked in on the ground shorten or fasten suction pipe
u
se filter screen with check valve
Pump does not switch off
cut out pressure set too high
contact dealer
Pressure side unsealed
WPB062S.V2| Issue 1 01/07/16
Original Language Version
© Jack sealey limited