background image

instructions for

surface mounting booster pump
stainless steel 3300ltr/hr 230V

model no: 

Wpb062s.V2

thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  safetY

1.1.    

electrical safetY

 

‰

  

Warning!

 it is the user’s responsibility to check the following:

 

check all electrical equipment and appliances to ensure that they are safe before using. inspect power supply leads, plugs and    

 

all electrical connections for wear and damage. sealey recommend that an rcd (residual current device) is used with all electrical  

 

products. You may obtain an rcd by contacting your local sealey dealer. 

 

if the pump is used in the course of business duties, it must be maintained in a safe condition and routinely PAt (Portable Appliance  

 

test) tested.

 

electrical safety information, it is important that the following information is read and understood.

1.1.1.   

ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.1.2.   

regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.1.3. 

  

important

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the    

 

correct fuse - see fuse rating in these instructions.

 

8

   Do  not

 pull or carry the appliance by the power cable.

 

8

  

Do not

 pull the plug from the socket by the cable. 

 

8

   Do  not

 use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or  

 

replaced 

immediately by a qualified electrician.

1.1.4. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

        

 if the cable or plug is damaged during use, switch the electricity supply and remove from use. 

        

 Ensure that repairs are carried out by a qualified electrician.

       

Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b) Connect the BROWN live wire to the live terminal ‘L’.

 

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

       

ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

       

Sealey recommend that repairs are carried out by a qualified electrician. 

1.2.    

general safetY

 

‰

  

Warning! 

Pump must be used in accordance with Health & safety, government, local authority and water authority rules and    

 regulations.

 

9

   familiarise yourself with the application, limitations and potential hazards peculiar to the pump.

 

‰

  

Warning!

 disconnect the pump from the mains power before servicing or performing any maintenance.

 

9

   maintain  the

 

pump in good condition (use an authorised service agent). Keep the pump clean.

 

9

   replace or repair damaged parts. 

Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

9

   only use for pumping cold or warm water (

not

 exceeding 35°c).

 

9

   if used in situations of possible flooding, user is responsible for installing appropriate back up procedures, alarms etc. in case of pump  

 failure.

 

9

   if used with swimming pools, fish ponds, etc., ensure areas are clear of people and animals (including removal of fish from ponds). note  

  that this pump is not designed for continuous use in a fish pond or similar water feature or display.

 

8

   Do  not

 operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.

 

8

  

Do not

 use the pump for any purpose other than for which it is designed and 

Do not

 modify it in any way.

 

8

  

Do not

 use to pump chemicals, fuels, fatty liquids or salt water.

 

8

  

Do not

 pump sludge, sand, gravel, mud, or fibrous materials. ensure the inlet hose will 

not

 pick up any solid materials. sand and  

  such substances will reduce working life of pump, and invalidate your warranty.

 

8

  

Do not

 use to pump septic tanks or settling pits. 

 

8

  

Do not

 submerge the pump or the electrical cable in water. Protect the pump from external wet conditions.

 

8

  

Do not

 operate pump during freezing temperatures. 

Do not

 allow any part of the pump or pipes to freeze.

 

8

  

Do not

 carry pump by the cable, or piping. only use the handle.

 

8

   Do not 

use the device in a location where there is a danger of explosion or in the vicinity of flammable

 

8

liquids or gases. liquids or gases.

WPB062S.V2| Issue 1 01/07/16

Original Language Version

© Jack sealey limited

refer to 

instruction 

manual

recommended fuse rating

13 Amp

Содержание WPB062S.V2

Страница 1: ... electrician a Connect the GREEN YELLOW earth wire to the earth terminal E b Connect the BROWN live wire to the live terminal L c Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY WARNING Pump must be...

Страница 2: ...ing pools the pump must be set up so as to guard against overflowing and protect against falling in 4 5 The installation site must be well ventilated and protected from the effects of weather 4 6 When operating indoors you must ensure that there is a drain in the floor or a leak prevention mechanism 4 7 Before starting up check the suction hose to ensure that it is sealed Bubbles of air in the suc...

Страница 3: ... certain circumstances result in too high a pressure 5 2 3 Plug in the mains plug 5 2 4 Open pressure line turn on water spigot or nozzle 5 2 5 Turn pump on at the On Off switch Check to be sure that water is coming out 5 2 6 If the motor does not start up or the pump does not build up any pressure or if similar faults occur turn the device off and try to remedy the error see Troubleshooting secti...

Страница 4: ...se Remedy Pump does not work No power supply Check power cable plug supply Motor overheat due to high liquid temperature Eliminate cause of overheating max liquid temperature is 35 C Motor overheats due to blocked ventilation slots Eliminate cause of overheating Residual current device activated Reset Motor defective Contact dealer Delivery rate too slow Water shortage Ensure sufficient water supp...

Отзывы: