9
make sure the work area is tidy and well lit.
9
Keep children and bystanders away from the work area.
8
Do not
operate pump whilst tired or under the influence of alcohol, drugs or medication.
9
maintain correct balance and footing, wear non slip shoes whilst positioning the pump.
8
Do not
point the water discharge towards another person, electrical wiring or equipment.
9
make sure that the pump is correctly positioned to prevent movement during use. ensure that the area around the pump is kept
clear.
9
When not in use switch off pump and remove plug from power supply. Rinse pump, drain out any water and store in a frost free, safe
location.
WARNING! DO NOT
allow uncontrolled discharge of contaminated water, thus polluting the environment.
NOTE:
this appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of
experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for
their safety. children should be supervised to ensure that they do not play with the appliance.
2. introDuction
manufactured from heavy duty corrosion resistant materials in a combination of stainless steel and polypropylene. ideal for boosting or
maintaining water pressure within the home or garden water supply. fitted with automatic pressure cut off and non return valve. integrated
regulator and pressure gauge. suitable for lifting water up to 8 metres. features 4 stable feet which can be securely mounted and a removable
filter for easier maintenance. The 24ltr pressure tank provides constant pressure.
3. specifications
model no: .........................................................
WPB062S.V2
cut out: .................................................................. Automatic
outlet: .......................................................................... 32mm
maximum output: .....................................................
3300ltr/hr
maximum head: .............................................................38mtr
maximum suction height:.................................................8mtr
maximum particle size: ................................................... 1mm
motor power: .................................................................
800W
supply: ...........................................................................
230V
tank size: ........................................................................24ltr
4. set up
4.1.
The pump must be placed on a horizontal, level surface that is capable of supporting the total weight of the device when filled with
water.
4.2.
to prevent vibrations, the pump should be placed on an elastic base support e.g. a rubber mat.
4.3.
For stationary use, the device can be screwed down firmly to the base with 4 screws.
4.4.
When being used on garden ponds and swimming pools, the pump must be set up so as to guard against overflowing and protect
against falling in.
4.5.
the installation site must be well ventilated and protected from the effects of weather.
4.6.
When operating indoors you must ensure that there is a drain in the floor or a leak prevention mechanism.
4.7.
Before starting up, check the suction hose to ensure that it is sealed. Bubbles of air in the suction hose are an indication that there
may be leaks and may lead to failure of the pump.
4.8.
connect suction line
Warning! Danger of damage to the pump.
the suction line must be installed so that it does not exert any mechanical force or tension on the pump.
If the conveying medium is contaminated, a suction filter must be used to protect the pump from sand and dirt.
note:
A check valve is recommended so that the water does not run off when the pump is shut off.
4.9.
All connections must be sealed with thread sealing tape or paste, e g. Teflon tape. Leaks cause air exhaust and reduce or prevent
water exhaust.
4.10.
the suction pipe should have an internal diameter of at least 25 mm; it must be kink resistant and suitable for vacuum use.
4.11.
the suction line should be as short as possible, since the conveying capacity decreases as the length of the line increases.
4.12.
the suction line should ascend steadily toward the pump to prevent air pockets.
4.13.
s
ufficient water supply must be assured; the end of the suction line must always be in water.
4.14.
connect pressure line
Warning!
the suction line must be installed so that it does not exert any mechanical force or tension on the pump.
4.15.
A
ll connections must be sealed with thread sealing tape, e.g. Teflon tape, leaks cause air exhaust and reduce or prevent water
exhaust.
4.16.
All components of the pressure line must be compression-proof.
4.17.
t
he device can also be connected firmly to a pipe system (e. g. for domestic water supply in the interior). In this case, the device
should be connected to the pipe system with elastic high-pressure flexible hose lines in order to prevent vibrations.
Warning!
Risk of injury. If the components are not compression-proof or if they are improperly installed, the pressure line could burst
during operation.
note:
the pump must not be used for drinking water supply.
1 Pressure gauge
2 Braided hose
3 intake
4 filter cover
5 Pressure joint
6 On-off
7 Compressed air valve
8 feet
WPB062S.V2| Issue 1 01/07/16
Original Language Version
© Jack sealey limited