1. Place dehumidifier on a level surface.
• Do not place unit directly on vapor barrier. For example, use blocks
or pavers to create a level surface.
• If unit has been turned or flipped so that the compressor did not
remain upright, place the unit on a level surface and wait a
minimum of 2 hours before proceeding.
2. Set up the drain line
• Remove the compression nut and slide it over the end of the hose
to be attached to unit.
• Slide the side of hose with compression nut over the insert on the
compression fitting completely.
• Tighten compression nut.
3. Plug dehumidifier into grounded 15 amp circuit.
Indicator Lights
• The display screen has two functions:
1. When the unit is powered on, it shows the humidity of the space
2. When setting the desired humidity level, the screen will show the
set point. After a brief delay, it will revert to current humidity of the
space.
1. Humidity Display Screen
2. Power Indicator Light
• This light indicates that the unit is properly powered on and ready to
operate.
• Always make sure the unit is “off” prior to performing any service, unless
otherwise indicated.
• If the humidity is above the setpoint, the light will be solid green and the
machine will operate.
• If the humidity is below the setpoint, the unit will be in standby mode and
the light will be flashing.
3. Continuous Mode/ Auto Defrost Light
• When the light illuminates green, it indicates that the dehumidifier
is set to continuous operation mode.
• When the light illuminates red, it means the unit is in auto defrost mode
and clearing the evaporator coils of any ice buildup.
4. Compressor Light
• When the light illuminates red, it indicates the compressor has been
initiated but is currently warming up.
• Once the light switches to green, it means the compressor is currently
in working status.
Содержание WatchDog NXT85C