10
**For more detailed instructions, visit www.SeairaGlobal.com**
WARNING: Always unplug the unit before doing any maintenance.
Cleaning the Filter
1. Unplug the unit.
2. For PreFilter:
a. Remove prefilter from inlet of machine.
b. Vacuum or wash with warm water (no soap).
3. For MERV-10/HEPA/Carbon Filters:
a. Replace as necessary- we recommend checking the filters
at least 1x/year
Electrical Access
• Unscrew the 9 screws on the side panel.
• Remove the 2 screws on the
control board cover.
Pump Maintenance
Your WatchDog NXT85c is equipped with an integral condensate pump
designed to pump water from the dehumidifier out to the desired drain.
The pump requires routine maintenance that is not covered by the
warranty.
Preventative maintenance is necessary to prevent issues from dirt and
slime that may accumulate in the drain system. This includes the drain
pan, hose to the condensate pump, pump reservoir, pump head assembly,
and discharge tubing.
Removing the Pump
1. Remove the 9 screws on the side panel and set panel aside.
2. Remove the screw holding the pump in place.
3. Undo the 3 pump electrical quick connects and 1
drain quick connect.
4. Insert a flat head screwdriver into the notch
on the side of the pump. This will allow you to
gently lift the pump off its reservoir (the reservoir
remains attached to the unit).
Содержание WatchDog NXT85C