3
Model Number: Date Of Purchase:
Specifications
Capacity @ 80°F/60%RH:
85 Pints Per Day
Airflow @ 0.0” SP:
190CFM
Operating Temp. Range:
33-105°F
Operating Relative Humidity Range:
36%-90%
COP:
2.7 L/kWh
Refrigerant:
R410A
Amperage Usage:
5.3 Amps
Power Supply:
115V/60Hz/Single Phase
Outlet Requirement:
15 Amp
Sound Level:
56 dBa
Dimensions
LxWxH:
21.7” x 12” x 12”
ETL Listed:
Yes
ENERGY STAR® Rated:
No
How It Works
WatchDog dehumidifiers use an integrated humidistat to monitor the
conditioned space. When the relative humidity goes above the selected
setpoint, the dehumidifier will energize. Air is then drawn across an
evaporator coil, which is cooler than the dew point of air. This means moisture
will condense out of the air. The air is then reheated through the condenser
coil and distributed back into the room.
Installation Requirements
• The area where the dehumidifier is located should be sealed with a vapor
barrier.
• If the unit is installed in a crawl space, all vents should be sealed.
• For proper ventilation, neither the inlet or discharge should be positioned
against a wall. The inlet needs a minimum of 12” clearance and the discharge
requires a minimum of 36” clearance.
• For the best air diffusion, install the unit so that a side panel faces the wall.
• WatchDog dehumidifiers are only intended for operation when the unit
is upright and level with the feet on the ground.