11
Basic Pump Cleaning
1. Remove filter(s) from inlet of unit to access drain tray. Press the
drain button to drain the reservoir.
2. Disconnect power to the dehumidifier.
3. Mix a 16 ounce solution of bleach (1 oz 15 oz water) OR
vinegar (4 oz white v 12 oz water).
4. Pour the cleaning solution into the drain tray at the base of the coils.
If any cleaning solution gets on the coils, flush with water.
5. Allow solution to soak for 15 minutes.
6. Reconnect the dehumidifier to power.
7. Fill the reservoir with water (16-32 ounces) and flush/cycle
the pump at least 2x.
8. If the drain line is still filled with debris, repeat process. If drain line
still does not appear clean, move on to Advanced Cleaning.
,
Complete about once per year, depending on environment
Advanced Pump Cleaning
Complete as needed
1. Press the drain button to drain the water from the reservoir (a wet-dry
vacuum or towels can be used to remove any remaining water).
2. Unplug the dehumidifier and remove the cover so you have access
to the pump.
3. Remove the pump head from the reservoir by unscrewing the screw.
Wipe reservoir clean with a paper towel.
4. Reassemble pump.
5. Mix a 16 ounce solution of bleach (1 oz 15 oz water) OR
vinegar (4 oz white v 12 oz water).
6. Pour the cleaning solution into the drain tray at the base of the coils.
If any cleaning solution gets on the coils, flush with water.
7. Allow solution to soak for 15 minutes.
8. Reconnect the dehumidifier to power.
9. Fill the reservoir with water (16-32 ounces) and flush/cycle the pump
at least 2x.
Содержание WatchDog NXT85C