g) The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the 
operator to start.

h) A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible.

i) For gate operators utilizing a non-contact sensor:

1) See instructions on the placement of non-contact sensors for each Type of application,
2) Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is 
still moving, and
3) One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the 
perimeter reachable by a moving gate or barrier.

j) For a gate operator utilizing a contact sensor:

1) One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading 
edge, trailing edge, and postmounted both inside and outside of a vehicular horizontal slide gate.
2) One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.
3) One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.
4) A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and 
the gate operator is not subjected to mechanical damage.
5) A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment 
protection functions shall be located where the transmission of the signals are not obstructed or impeded by building 
structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-
use conditions.
6) One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the 
bottom edge of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one or 
more contact sensors shall be located on the bottom edge.
7) One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).

Revised 56.8.4 effective February 21, 2008

Instruction regarding intended operation of the gate operator shall be provided as part of the user instructions or as a separate 
document. The following instructions or the equivalent shall be provided:
IMPORTANT SAFETY INSTRUCTIONS
WARNING – To reduce the risk of injury or death:

1. READ AND FOLLOW ALL INSTRUCTIONS.

2. Never let children operate or play with gate controls. Keep the remote control away from children.

3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.

4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-
contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate 
operator properly can increase the risk of injury or death.

5. Use the emergency release only when the gate is not moving.

6. KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified service person make repairs to gate 
hardware.

7. The entrance is for vehicles only. Pedestrians must use separate entrance.

8. SAVE THESE INSTRUCTIONS.

REV 02 - 12/2013

Содержание saturn-boxer 1000

Страница 1: ...REDUCER 120V FOR SLIDING GATES International registered trademark n 2 777 971 REV 02 12 2013 67411165 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 59...

Страница 2: ...sensitivity Instructions for the installation adjustment and wiring of external controls and devices serving as required protection against entrapment shall be provided with the operator when such con...

Страница 3: ...d where the transmission of the signals are not obstructed or impeded by building structures natural landscaping or similar obstruction A wireless contact sensor shall function under the intended end...

Страница 4: ...g gates with grease lubrication or in oil bath depending on the versions The irreversibility of the motor reducers allows a perfect and safe gate closing and makes the installation of an elecric lock...

Страница 5: ...D i r er h u t r s ou ea S E m E E K t y a AR t e L y P a a C v n e o m a t i G e m u in o r w a n r ri W h o p t i t g o a y D e e n l l r t g r a i r e t d l a h e p e o o h e p n c t o n t i t h e...

Страница 6: ...Insert the 4 grains into the special holes so that it is possible to adjust the motor reducer height on the plate Fig 15 At the end of installation check if the 4 crub screws are well gripped on the f...

Страница 7: ...laced on the upper part in case of inductive limit switch Fig 24 in corrispondence of pointX which is placed 1 96 in from the folded side of the small plate fig 25 and fix it with the delivered screws...

Страница 8: ...28 Fig 29 Inductive limit switch Fig 26 1 96 in X Fig 25 Position in which must be the spring mechanical limit switch or the pointer inductive limit switch SATURN BOXER 67411165 8 MECHANICAL INSTALLA...

Страница 9: ...llation for people things and animals Re Laws in force in the country where the installation has been made 14 NOTICE SEAUSAInc can not be deemed responsible for any damage or accident caused by produc...

Страница 10: ...control unit is reactivated only if a micro switch is mounted FOR SATURN 17 RELEASE SYSTEM FOR BOXER 17 1 In order to release do as follows Open the lock cover insert the key and rotate it 90 clockwis...

Страница 11: ...for the original buyer only Hydraulic and oil bath motors 36 months warranty from the date of invoice on manufacturing assembling and workmanship defects Electro mechanic motors and electronic contro...

Страница 12: ...sea usa com e mail sales sea usa com International registered trademark n 2 777 971 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free...

Отзывы: