6.20
S
ECTION
6 • E
LECTRICAL
S
YSTEM
300 Sundancer
®
(335 Sundancer
®
)
A. S
TARTING
T
HE
G
ENERATOR
(Remote control switches are located on the main
distribution panel or local switches on the
generator.)
1. Check fuel tank levels.
2. Check oil and coolant levels.
See Generator Operator’s
Manual for proper readings.
3. Check generator for coolant
drain plug installation.
4. Open the generator seacock.
5. Run the bilge blowers for at
least four minutes before
starting and any time the
generator is running.
If fuel
fumes are detected, do
not start the generator
until the source of fumes is determined and
corrected and the bilge area is safely
ventilated.
6. While holding the
PREHEAT switch
depressed, depress the
START switch. The starter
motor will run, thereby
cranking the engine. As
soon as the engine runs, release the START
switch, but continue to hold the PREHEAT
switch depressed for 2 or 3 seconds. Release
the PREHEAT switch when the oil pressure
reaches approximately 20 psi. This bypasses
the Low Oil Pressure shutdown until the
engine’s oil pressure rises to it’s normal running
pressure. Now release the PREHEAT switch.
7. Check generator exhaust port to verify that
water is flowing. If not, shut generator down
and refer to your Generator Operator’s Manual.
NOTE:
To start the Westerbeke
®
generator from
the generator mounted controls, a bypass switch,
located on the side of the generator mounted control
box, must be turned ON. The bypass switch must
be OFF to start and stop the generator from the
DC main distribution panel.
READ THE OWNER’S MANUAL IN THE
OWNER’S MANUAL PACKET FOR YOUR
GENERATOR MODEL.
Pre-start generator prior to getting underway as there
is a possibility that it will not pick up water if started
underway. Make sure the MAIN GENERATOR breaker
is OFF and there is no load on the generator before
starting it.
NOTICE
DO NOT run the engine or generator in an enclosed
area, such as a closed boat house, as there is the
possibility of buildup and inhaling of carbon
monoxide.
!
WARNING
B. S
HIFTING
F
ROM
S
HORE
P
OWER
TO
G
ENERATOR
P
OWER
.
1. Turn all AC systems and
branch circuit breakers OFF.
Turn both main breakers on
the main distribution panel
OFF.
2. Start the generator.
3. Slide the source select
shuttle mechanism on the
main distribution panel to
expose the GENERATOR
breaker(s) and turn it ON.
4. Turn the individual system
breakers ON.
E
F
Fuel
GENERATOR
SHORE
OFF
ON
OFF
ON
BILGE
GENERATOR
PREHEAT/ON
BLOWERS
START/RUN
BILGE
GENERATOR
PREHEAT/ON
BLOWERS
START/RUN
Содержание 300 Sundancer
Страница 1: ...300 Sundancer International 335 Sundancer Owner s Manual Part Number MRP1815325 Sea Ray Owner s Manual...
Страница 2: ......
Страница 4: ...ii 300 Sundancer 335 Sundancer...
Страница 30: ...This page intentionally left blank...
Страница 54: ...3 10 SECTION 3 USING YOUR BOAT 300 Sundancer 335 Sundancer THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 60: ...SECTION 4 BILGE UNDERWATER GEAR 4 6 300 Sundancer 335 Sundancer THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 132: ...7 16 SECTION 7 OPTIONS ACCESSORIES 300 Sundancer 335 Sundancer THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 154: ...9 4 SECTION 9 CARE REFINISHING 300 Sundancer 335 Sundancer THIS PAGE LEFT INTENTIONALLY BLANK...