INSTALLATION INSTRUCTIONS

Model 936 EntryCheck

The 936 EntryCheck

 is a powerful yet easy to use, stand alone keyless entry system with features suitable for a 

variety of  access control requirements. Providing either a voltage output or dry contact closure, the 936 is designed 
to control any fail-safe or fail-secure electric locking device.

The 936 EntryCheck

 can accommodate up to 500 user codes, each assignable to one of three programmable 

outputs.  The 936 provides an enhanced level of security by storing the relay outputs in a separate control module.  
The three relay outputs are available to provide a variety of access control configurations including single door 
operation with two auxiliary output for a CCTV/Light Controller, Internal Alarm, 2

nd

/3

rd

 Door, or Doorbell activation.

All user programming and system configuration can be performed through the Keypad or PC programming software.
Additional features include a tamper alarm, forced door alarm, door ajar alarm, remote bypass, time clock input, and 
real-time event logging while connected to a PC.

Содержание EntryCheck 936

Страница 1: ...losure the 936 is designed to control any fail safe or fail secure electric locking device The 936 EntryCheck can accommodate up to 500 user codes each assignable to one of three programmable outputs...

Страница 2: ...g Device 7 Hardware Setup 8 Voltage Selection 8 Keypad Output Selection 8 Restoring System Defaults 9 Keypad Reset 9 Normal System Operation 10 Keypad LED Status Indicators 10 Tamper Alarm 10 Control...

Страница 3: ...and Relay Control Module The 500 user code system consists of either a 3x4 or 2x6 Keypad and a Relay Control Module KEYPAD WITH CONTROL MODULE PART NUMBERS 3x4 Keypad with Control Module P N 936 x KP...

Страница 4: ...A A relay contact output that can be programmed for one of the following 1 CCTV or Light Controller First key press triggers a Timed Output 1 to 99 seconds 2 Auxiliary Output Manual Control or Timed O...

Страница 5: ...LLOW and BLACK the door will relock immediately after opening If Output B is set up as Internal Alarm this switch will trigger the alarm if the door is opened without a code or if the door is left ope...

Страница 6: ...ad Weight 5 H x 3 W x 7 16 D 13 x 8 6 x 1 1cm 7 H x 1 W x D 18 1 x 4 4 x 1 9cm 3x4 Keypad Dimensions 2x6 Keypad Dimensions 1 Red 1 Green LED s 16 oz 454 gm Control Module Weight 40 F to 120 F 40 C to...

Страница 7: ...which only 8 wires are used If the Control Module must be located further than 15 feet from the Keypad additional cable may be spliced The maximum distance between the Keypad and the Control Module m...

Страница 8: ...T 936 vsd 0106 Page 6 Mounting Instructions KP 31U and KP 31Y The 2x6 keypad is designed for mullion mount applications It can also be mounted on a wall pedestal or any flat surface of at least 1 by 7...

Страница 9: ...ic lock For switching voltages higher than 36V remove the MOV To provide proper grounding connect the 3rd wire from the body of the locking device to the EARTH screw on Terminal A 1 Connect the Wiring...

Страница 10: ...o flash and the GREEN LED will be solid If you hear a long error beep reenter 98 followed by To change the audible beep or illumination proceed as follows Otherwise go to step 5 a To change the audibl...

Страница 11: ...the Keypad will appear dead Do NOT remove power 5 Enter 98 followed by You should hear 3 beeps indicating successful completion the RED LED will continue to flash and the GREEN LED will be solid If y...

Страница 12: ...d to operate Manual Latching The User Commands are trailing digits entered after an authorized user code The ability to use these User Commands depends on authorizations assigned to each User see page...

Страница 13: ...the Control Module or the Control Module is in LockUp Mode the Keypad will indicate the problem by flashing the Red LED very fast Since the Encode Code EC is only sent at the beginning of a Latch Ope...

Страница 14: ...load to the Control Module If programming has been done at the Keypad you can download from the Keypad to a blank code chart names are not stored in the Keypad so they will be blank or MERGE the Keypa...

Страница 15: ...stop logging events and place the program in idle mode click on the RED square icon To clear the log stop the event logger Select the OPERATION menu and CLEAR LOG Set up If BIND is blank the log will...

Страница 16: ...Beep Red LED Green LED Triple Fast Flash Solid Note If you forget the Master Code locate and press the PROGRAM button on the Control Module board This will take you into System Setup Once you enter se...

Страница 17: ...ce for Manual Operation ON OFF followed by Example 4 2 0 Sets Auxiliary Device with Manual Operation iii Second Door a Enter 3 b Enter the desired Door Open Time 1 99 seconds followed by c Select the...

Страница 18: ...ce with Manual Operation iii Third Door a Enter 3 b Enter the desired Door Open Time 1 99 seconds followed by c Select the desired latching method Off 0 Manual 9 9 Timed Enter the desired time interva...

Страница 19: ...ult Prevent A Enter 7 B Enter 0 to prevent lockout C Enter 1 to lockout all users that do not have 24 hour option enabled D Select another programming option 1 8 or enter to exit programming 8 Baud Ra...

Страница 20: ...s you to restrict access to Users who are not assigned 24 hour Access See Time Clock Input on page 3 1 Adding a New User A Enter 1 B Enter the User ID 1 to 499 followed by C Enter the User Code PIN 3...

Страница 21: ...ime to complete programming sequence and reset system to normal operation 3 Modify a User by User Code A Enter 3 B Enter the User Code for the User you wish to modify followed by C To change this User...

Страница 22: ...ted enter to select another programming option 1 7 or if you have completed all User Programming enter a second time to complete programming sequence and reset system to normal operation 6 Adding a Te...

Страница 23: ...2 1 RELAY 1 RELAY 2 RELAY 3 12 24 AC IN 1 2 PROGRAM RED GREEN A B C 3 2 1 4 5 6 7 8 9 10 11 12 Terminals 2 3 4 9 10 11 12 to the keypad Terminals 7 8 to Clock or keyswitch contacts Terminals 5 6 to Re...

Страница 24: ...NSTALLATION INST Access Control INST 936 vsd 0106 Page 22 NC 3 NO 3 COM3 NC 2 NO 2 COM2 NC 1 NO 1 COM1 12 24 DC IN OUT 11 10 9 8 7 6 5 4 3 2 1 RELAY 1 RELAY 2 RELAY 3 12 24 AC IN 1 2 B C FAIL SECURE L...

Отзывы: