this appliance cannot operate in a de-pressurised room.
the presence of a hood, mechanically controlled ventilation or another heating appliance requiring air in
a well insulated dwelling may cause disturbances (incorrect combustion, smoke drawn back into the
room, etc.). It is important that sufficient quantity of air needed to burn the wood can be drawn from the
room. When the room’s air intake is insufficient( well insulated and(or) 6 Star rated(or more) homes), a
specific air intake must be installed in conjunction with the appliance(outdoor airkit).
In the case of an unconnected appliance, the air intake specific to the wood heater must have a
minimum 300cm 2 surface area. it must be located either directly outside, or in a room ventilated to
the outside, and must arrive at the base of the inset wood heater. it must be protected by a vermin
proof grate. possible heat losses due to the creation of a duct that is too long should also be taken into
consideration.
It is preferable to connect to outdoor air in order to optimise combustion control. Depending on specific
building-related conditions (air tightness, presence of mechanically controlled ventilation, presence of a
kitchen hood, etc).
4. inStall GUide
these instructions are to be kept by the user, the installer under any circumstances mUSt not dispose
of this manual. following installation it is recommended the installer review any questions or queries
the new user might have, this should include lighting the fire and explaining the various functioning
components of the appliance. Insist on the wood quality, on the need to light the fire correctly and have
correct combustion in order to avoid all problems related to smoke emission in the room or blackened
glass.
thEsE installation instruCtions arE an intEgral Part oF thE aPPlianCE anD
shoulD bE kEPt inDEFinitEly, shoulD thE unit bE solD this Manual shoulD
aCCoMPany thE unit.
CoMMissioning thE aPPlianCE
CoMbustion air
DirECt outDoor air ConnECtion
inDirECt outDoor air ConnECtion