43
Setting up the eyesite 550
Input Mode
The
Input Mode
control selects the eyesite 550’s response to
a trigger input.
Alarm In
When the trigger is activated the eyesite 550 dials
the number stored in the phonebook and saves the pre-alarm
information. The autodialer must be enabled for an alarm in
trigger to cause the unit to dial.
Event In
When the
Event In
trigger is activated the eyesite
550 sends an event message to a StatIX server which in turn
sends an e-mail or SMS message to a configureed recipient.
Status
Allows a remote operator using eyesite for Windows
Pro to see the status of the trigger input. This is useful for
monitoring open doors, and other alarm devices.
Input Sense
Active Low
. Zero input voltage triggers an event.
Active High
Connection to a voltage in the range +5 to + 12v
triggers an event.
Normally Closed (NC)
A break in a normally closed circuit
such as a connection to a door or window contact switch
triggers an event.
Normally Open (NO)
A contact closure triggers an alarm or
event- for example a pushbutton in an access control
application.