background image

8

P/N 595141-01 Rev A  7/08

DONNING AND USE OF THE PROFLOW FH22 HOOD
WITH THE PROFLOW 3 PAPR

The PROFLOW FH22 Hood and the PROFLOW 3 must be properly attached
and  donned  before  use.  Donning  the  PROFLOW  FH22  Hood  and  the
PROFLOW 3 must be done in an area know to be free of contaminants. The
respirator user must have received training in accordance with these instruc-
tions and with the instructions provided with the PROFLOW 3 and must have
practiced these procedures before attempting to use the respirator for respi-
ratory protection.
1. Examine the PROFLOW FH22 Hood to be certain it is complete and in

serviceable condition. See the REGULAR OPERATIONAL INSPECTION
section of this instruction for details. If not already removed, remove the
protective paper from the front of the visor window.

2. Examine the breathing tube assembly to verify that it is properly con-

nected to both the PROFLOW FH22 Hood and to the blower assembly.
See ATTACHING THE PAPR BREATHING TUBE section of this instruc-
tion.

3. Examine air filtration elements to verify that they are correct for protec-

tion from the hazardous atmosphere and properly installed to the blower
assembly.

WARNING

T H E   P R O F L O W   F H 2 2   H O O D   D O E S
N O T  P R O V I D E  A N Y  R E S P I R AT O RY
P R O T E C T I O N   W I T H O U T   P R O P E R
U S E   O F   T H E   P R O F L O W   3   P O W -
E R E D  

A I R  

P U R I F Y I N G

R E S P I R ATO R  ATTA C H E D  TO  I T.  I M -
P R O P E R  U S E  O F  T H I S  E Q U I P M E N T
M AY   R E S U LT   I N   E X P O S U R E   T O
T H E   H A Z A R D O U S   AT M O S P H E R E
W H I C H   M AY   C A U S E   S E R I O U S   I N -
J U RY   O R   D E AT H .

WARNING

THE FAILURE TO CHOOSE A RESPIRA-
TOR  EQUIPPED  WITH  FILTRATION
ELEMENTS  SUITABLE  FOR  THE
CONTAMINANT(S) IN THE ATMOSPHERE
OR LIKELY TO BE RELEASED IN THE AT-
MOSPHERE  MAY  RESULT  IN  THE
RESPIRATOR PROVIDING LITTLE OR NO
PROTECTION AGAINST THE CONTAMI-
NATED ATMOSPHERE WHICH MAY LEAD
TO SERIOUS INJURY OR DEATH.

7. Turn the inner and outer aprons of the PROFLOW FH22 Hood inside-

out to provide access to the head band area. See FIGURE 7.

4. TURN  ON  THE  BLOWER  UNIT

BEFORE 

DONNING 

THE

PROFLOW  FH22  HOOD. To turn
on  the  PROFLOW  3  blower  unit,
push the push-button switch to the
ON  position  to  confirm  that  the
blower is working and the battery
is fully charged. Leave the blower
ON while donning the PROFLOW
FH22 Hood.

5. Don  the  waist  belt  with  the

PROFLOW 3 blower assembly so
that the breathing tube outlet is lo-
cated at the top of the unit. Fasten
the  buckle  and  adjust  the  waist
belt. See FIGURE 6.

6. Position blower assembly on back

of the hip on left side of the body.
When  properly  donned,  the  ON/
OFF switch shall be accessible to
the  user  and  the  digital  display
shall be visible to the user.

FIGURE 6

FIGURE 7

WARNING

TURN ON THE BLOWER UNIT BEFORE
DONNING THE PROFLOW FH22 HOOD.
FAILURE  TO  TURN  ON  THE  BLOWER
MAY RESULT IN INSUFFICIENT BREATH-
ING  AIR  INSIDE  THE  HOOD  WHICH
COULD RESULT IN SERIOUS INJURY OR
DEATH.

Содержание PROFLOW FH22

Страница 1: ...CH COMPLIES WITH THE REQUIREMENTS OF A NATIONALLY RECOGNIZED STANDARD SUCH AS OSHA SAFETY AND HEALTH STANDARD 29 CFR 1910 PARAGRAPH 134 AVAILABLE FROM THE US DEPART MENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION THIS EQUIPMENT IS NOT INTENDED FOR USE IN ATMOSPHERES WHICH ARE OR MAY BECOME IMMEDIATELY DAN GEROUS TO LIFE OR HEALTH IDLH IN HIGH TEMPERATURE ENVIRONMENTS SUCH AS FIRES OR I...

Страница 2: ...to connect the Hood to the PROFLOW 3 respirator Refer to the NIOSH Approval Label included with the PROFLOW 3 respirator for a complete listing of hoods and filters approved for use with the SCOTT PROFLOW 3 respirator When used with a PROFLOW 3 PAPR contaminated air is drawn through the filtration elements mounted on the PROFLOW 3 blower unit and flows through the breathing tube to the respiratory...

Страница 3: ...rsons trained in evaluating the specific end use conditions and in selecting the appropriate chemical protective equipment Consult a qualified industrial hygienist for advice on the use of the PROFLOW FH22 PAPR Hood in your work environment Take into consideration that seams and closures often have shorter breakthrough times and higher chemical permeation rates than the fabric alone Anyone intendi...

Страница 4: ... the breathing tube Do not use the breathing tube with a missing or damaged gasket Remove the breathing tube from service and tag for repair by authorized personnel If any damage or discrepancies are found remove the PROFLOW FH22 Hood from service and tag for disposal and replacement In addition the materials used in these hoods are not suitable for use in high temperature applications like fire f...

Страница 5: ...or replacement 2 Hold the end of the hose as above and place the threaded end of the hose through the opening at the back of the hood Opening should fit snug around the threaded end of the hose 3 Carefully turn the hood inside out to access the end of the hose on the inside of the hood Be careful not to bend the Visor Window See FIGURE 1 4 Place the plastic washer on the threaded hose end 5 Carefu...

Страница 6: ...channel opening Insert the end of the tie wrap through the lock and engage one or two teeth to form a loop large enough to fit over the breathing tube FIGURE 3 2 Repeat step 1 with another tie wrap in the channel at the other end of the shroud 3 Slide the breathing tube shroud over the end of the breathing tube and position the first end as shown in FIGURE 4 The tie wrap should be just below the h...

Страница 7: ...LOW 3 INSTRUCTION 3 Attach the female end of the breathing tube onto the blower assembly by threading the collar onto the air outlet clockwise until hand tight REMOVE THE BREATHING TUBE SHROUD AS FOLLOWS 1 The tie wraps are the removable type On the lock end press down on the lock release below the cut off end of the tie wrap while pulling the loop open 2 If desired the tie wraps may be cut off an...

Страница 8: ... R P U R I F Y I N G RESPIRATOR ATTACHED TO IT IM PROPER USE OF THIS EQUIPMENT M AY R E S U LT I N E X P O S U R E T O T H E H A Z A R D O U S AT M O S P H E R E WHICH MAY CAUSE SERIOUS IN JURY OR DEATH WARNING THE FAILURE TO CHOOSE A RESPIRA TOR EQUIPPED WITH FILTRATION ELEMENTS SUITABLE FOR THE CONTAMINANT S IN THE ATMOSPHERE OR LIKELY TO BE RELEASED IN THE AT MOSPHERE MAY RESULT IN THE RESPIRAT...

Страница 9: ...clothing the inner apron may be fitted inside the collar of the protective clothing while the outer apron drapes over the outside of the protective clothing The additional protec tive clothing must not interfere with the integral exhalation opening on the front of the hood Also the additional protective clothing must not restrict the air flow to the air filtration elements on the PROFLOW 3 Verify ...

Страница 10: ...and proceed to de contamination if necessary 2 When decontamination is complete and it is safe to remove the PROFLOW FH22 Hood and respirator a Loosen the neck cord by pressing the black button inward as you slide the cord lock away from your chin b Roll up the PROFLOW FH22 Hood starting at the bottom rear and proceeding up the back of the neck See FIGURE 10 c Remove the head from the head band Se...

Страница 11: ...ntaminant may be present PROFLOW FH22 Hood must be handled as a contaminated or potentially contami nated object 3 The PROFLOW FH22 Hood is intended for a single use Dispose of the used hood according to the procedures defined by your respiratory pro tection program and in accordance with federal state and local environmental regulations STORAGE Store new unused hoods in their sealed packages betw...

Страница 12: ...12 P N 595141 01 Rev A 7 08 Health Safety Products Monroe Corporate Center PO Box 569 Monroe NC 28111 Telephone 1 800 247 7257 FAX 704 291 8330 www scotthealthsafety com Printed in USA ...

Отзывы: