Scott PROFLOW FH22 Скачать руководство пользователя страница 3

3

P/N 595141-01 Rev A  7/08

WARNING

THE  MATERIALS  THAT  MAKE  UP  THE
PROFLOW  FH22  HOOD  ARE  UNSUIT-
ABLE  FOR  EXPOSURE  TO  SOME
CHEMICALS.  EXPOSURE  OF  THE
PROFLOW  FH22  HOOD  TO  ANY  OF
THESE CHEMICALS MAY CAUSE RAPID
FAILURE  OF  THE  PROTECTIVE  MATE-
RIAL  EXPOSING  THE  USER  TO  THE
HAZARDOUS  ENVIRONMENT  WHICH
COULD LEAD TO SERIOUS INJURY OR
DEATH.

CHOOSING THE APPROPRIATE EQUIPMENT

Respirators reduce but do not eliminate all exposure to the hazardous atmo-
sphere. Some respirators are more effective than others at reducing exposure
depending on the nature and the concentration of the contaminant in the
hazardous atmosphere. When choosing a respirator, the respiratory protec-
tion program under which this respirator is to be used must determine the
appropriate level of protection that the respirator is expected to provide. 

Use

of inappropriate RESPIRATOR equipment for the work environment may
result in exposure to the hazardous atmosphere which may cause seri-
ous injury or death.

No  material  is  perfectly  resistant  to  all  chemical  substances.  It  is  the  re-
sponsibility of the respiratory protection program under which this equipment
is used to decide on a case by case basis the appropriateness, duration of
use, and re-use of the PROFLOW FH22 Hood.

The polyester coated synthetic fabric material used in the construction of
the PROFLOW FH22 Hood and Breathing Tube Cover is considered suit-
able for providing limited protection from the following:

The  PROFLOW  FH22  Hood  material  is  considered 

UNSUITABLE

  for

providing protection from the following:

SCOTT PROFLOW FH22 PAPR Hoods must only be selected by persons
trained  in  evaluating  the  specific  end-use  conditions  and  in  selecting  the
appropriate  chemical  protective  equipment.  Consult  a  qualified  industrial
hygienist for advice on the use of the PROFLOW FH22 PAPR Hood in your
work environment. Take into consideration that seams and closures often
have shorter breakthrough times and higher chemical permeation rates than
the fabric alone.
Anyone intending to use chemical protective equipment must first verify that
the equipment is suitable for the intended use as part of a complete respira-
tory protection program.
This hood and the breathing tube cover are intended only for a single use
and disposal after use, for example, after a single shift of work. Choosing to
clean and re-use this equipment is at the discretion and risk of the user and
the respiratory protection program.

SCOTT recommends that after use and before disposal, inspect the hood
material for signs of permeation or damage caused by chemical exposure. If
there is evidence of permeation:

·

Refer to the Material Safety data Sheet (MSDS) for the chemicals in-
volved for information about the possible hazards of exposure,

·

Consider whether this hood material is suitable for your particular appli-
cation.

Moderate Liquid Chemical Splash
Liquid Organic Chemicals and Flash Fire Potential
Heavy Liquid Chemical Splash (toxics and corrosives)
ChemBio and WMD Agents

Chemical Vapors and Gases (toxics and corrosives)

Organic Solvents
Methamphetamines
Known Carcinogens
Sarin, Mustard,
VX Nerve Agents
Chlorine,
Anhydrous Ammonia

HAZARDS

EXAMPLES

Dry Pharmaceutical Chemicals
Blood, Saliva
Inorganic Acids and Bases, Salts

Hazardous Dry Powders and Solids
Blood borne Pathogens and Biohazards
Light Chemical Splash and Aerosols

HAZARDS

EXAMPLES

CHOOSING THE APPROPRIATE EQUIPMENT

CONTINUED ON NEXT PAGE...

Содержание PROFLOW FH22

Страница 1: ...CH COMPLIES WITH THE REQUIREMENTS OF A NATIONALLY RECOGNIZED STANDARD SUCH AS OSHA SAFETY AND HEALTH STANDARD 29 CFR 1910 PARAGRAPH 134 AVAILABLE FROM THE US DEPART MENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION THIS EQUIPMENT IS NOT INTENDED FOR USE IN ATMOSPHERES WHICH ARE OR MAY BECOME IMMEDIATELY DAN GEROUS TO LIFE OR HEALTH IDLH IN HIGH TEMPERATURE ENVIRONMENTS SUCH AS FIRES OR I...

Страница 2: ...to connect the Hood to the PROFLOW 3 respirator Refer to the NIOSH Approval Label included with the PROFLOW 3 respirator for a complete listing of hoods and filters approved for use with the SCOTT PROFLOW 3 respirator When used with a PROFLOW 3 PAPR contaminated air is drawn through the filtration elements mounted on the PROFLOW 3 blower unit and flows through the breathing tube to the respiratory...

Страница 3: ...rsons trained in evaluating the specific end use conditions and in selecting the appropriate chemical protective equipment Consult a qualified industrial hygienist for advice on the use of the PROFLOW FH22 PAPR Hood in your work environment Take into consideration that seams and closures often have shorter breakthrough times and higher chemical permeation rates than the fabric alone Anyone intendi...

Страница 4: ... the breathing tube Do not use the breathing tube with a missing or damaged gasket Remove the breathing tube from service and tag for repair by authorized personnel If any damage or discrepancies are found remove the PROFLOW FH22 Hood from service and tag for disposal and replacement In addition the materials used in these hoods are not suitable for use in high temperature applications like fire f...

Страница 5: ...or replacement 2 Hold the end of the hose as above and place the threaded end of the hose through the opening at the back of the hood Opening should fit snug around the threaded end of the hose 3 Carefully turn the hood inside out to access the end of the hose on the inside of the hood Be careful not to bend the Visor Window See FIGURE 1 4 Place the plastic washer on the threaded hose end 5 Carefu...

Страница 6: ...channel opening Insert the end of the tie wrap through the lock and engage one or two teeth to form a loop large enough to fit over the breathing tube FIGURE 3 2 Repeat step 1 with another tie wrap in the channel at the other end of the shroud 3 Slide the breathing tube shroud over the end of the breathing tube and position the first end as shown in FIGURE 4 The tie wrap should be just below the h...

Страница 7: ...LOW 3 INSTRUCTION 3 Attach the female end of the breathing tube onto the blower assembly by threading the collar onto the air outlet clockwise until hand tight REMOVE THE BREATHING TUBE SHROUD AS FOLLOWS 1 The tie wraps are the removable type On the lock end press down on the lock release below the cut off end of the tie wrap while pulling the loop open 2 If desired the tie wraps may be cut off an...

Страница 8: ... R P U R I F Y I N G RESPIRATOR ATTACHED TO IT IM PROPER USE OF THIS EQUIPMENT M AY R E S U LT I N E X P O S U R E T O T H E H A Z A R D O U S AT M O S P H E R E WHICH MAY CAUSE SERIOUS IN JURY OR DEATH WARNING THE FAILURE TO CHOOSE A RESPIRA TOR EQUIPPED WITH FILTRATION ELEMENTS SUITABLE FOR THE CONTAMINANT S IN THE ATMOSPHERE OR LIKELY TO BE RELEASED IN THE AT MOSPHERE MAY RESULT IN THE RESPIRAT...

Страница 9: ...clothing the inner apron may be fitted inside the collar of the protective clothing while the outer apron drapes over the outside of the protective clothing The additional protec tive clothing must not interfere with the integral exhalation opening on the front of the hood Also the additional protective clothing must not restrict the air flow to the air filtration elements on the PROFLOW 3 Verify ...

Страница 10: ...and proceed to de contamination if necessary 2 When decontamination is complete and it is safe to remove the PROFLOW FH22 Hood and respirator a Loosen the neck cord by pressing the black button inward as you slide the cord lock away from your chin b Roll up the PROFLOW FH22 Hood starting at the bottom rear and proceeding up the back of the neck See FIGURE 10 c Remove the head from the head band Se...

Страница 11: ...ntaminant may be present PROFLOW FH22 Hood must be handled as a contaminated or potentially contami nated object 3 The PROFLOW FH22 Hood is intended for a single use Dispose of the used hood according to the procedures defined by your respiratory pro tection program and in accordance with federal state and local environmental regulations STORAGE Store new unused hoods in their sealed packages betw...